MAURY USCG vessel records
← All vessels

THASSOS

THASSOS is a 2011 freight ship. The Coast Guard has recorded 5 inspections since 2020, most recently in January 2025, along with 1 deficiency and 1 operational control, 1 with no removal date recorded.

Records from 2020 to 2025. Most recent: inspection, 7 January 2025.

Built
2011
Last inspected
7 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 January 2025
Operational controls 1 with no removal date recorded
Years with a record 4 calendar years (2020–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9567233
9HA4153
1381311
Flag
MALTA
Maury page id
psix-1381311

Documentation record

Tonnage as PSIX records it32964 - Convention (Subpart B), Gross Ton
56759 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
19142 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

7 January 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8059629
19 November 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8032456
18 January 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7377891
10 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7378218
15 January 2020 PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6882217

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 November 2024 Resolved
Electrical installations shall be such that: the safety of the passengers, crew, and ship from electrical hazards will be ensured. PSCO observed radial cracks where electrical conduit pipes meet junction boxes on port side main deck. SOLAS 74 (2009) II-1/40.1.3. 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 November 2024
Resolved 5 January 2025
Resolution: PSC NOLA received a class report from Rina satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.