Records from 2016 to 2026. Most recent: inspection, 5 March 2026.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 11.5 ft × 3.8 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2016
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationTri Hull
Hailing portLEAGUE CITY, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
9 - Displacement, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
5 March 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8320545
16 February 2026
Administrative Inspection · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8311143
27 October 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8259313
28 April 2025
Administrative Inspection · Excursion Permit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8121818
25 February 2025
Excursion Permit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8084089
7 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8015562
29 September 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7800812
24 February 2023
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7641650
27 September 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7567379
10 August 2021
Deficiency Check · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7282641
30 March 2021
Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7165496
4 September 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7056069
30 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6767711
28 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6458748
11 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6205133
25 October 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6029531
31 March 2016
Administrative Inspection · Deadweight Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5844593
14 March 2016
Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5832935
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 October 2022
Resolved
A self priming, power driven, fire pump must be installed on each vessel...of not more than 65 feet in length that carries more than 49 passengers.
Marine Inspector discovered no fire pump installed on vessel.
Install self priming, power driven fire pump on board to the satisfaction of a Coast Guard marine Inspector.
Passenger count reduced to 49 or less until regulation is met.
46 CFR 181.300(a)(ii)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: Vessel installed two additional 40BC fire extinguishers until fixed fire pump can be installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 October 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Vessel does not have FCC Safety Radio Telephony certificate for radio installation. Provide copy of certificate following completion of required inspection.
46 CFR 184.502
47 CFR 80.903
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 18 November 2022
Resolution: New FCC Safety Radio Telephony Cert on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2021
Resolved
Vessel had life ring that was the incorrect size.
Action required: 10 - Deficiency Rectified
Due 10 August 2021
Resolved 10 August 2021
Resolution: Master replaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2021
Resolved
Light float battery was of the incorrect type.
Restricted to daylight operations.
Action required: 705 - Other - as specified
Due 24 August 2021
Resolved 12 August 2021