MAURY USCG vessel records
← All vessels

GALATEIA

GALATEIA is a 2016 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in October 2025, along with 8 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 8 October 2025.

Built
2016
Last inspected
8 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 October 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9715438
1381458
Flag
LIBERIA
Maury page id
psix-1381458

Documentation record

Tonnage as PSIX records it81886 - Dead Weight, Metric Ton
94361 - Displacement, Metric Ton
43036 - Convention (Subpart B), Gross Ton
27490 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

8 October 2025 Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8249593
15 March 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7872094
10 May 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7442150
24 July 2020 Ballast Water Examination · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7008500
30 September 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6824296
23 December 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6590603
28 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6311429
16 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6242297
29 November 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6046506

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 March 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammabel liquids. PSCO observed excessive amounts of pooled FO in the vicinity of the #1 FO purifier. 74SOLAS(20) II-2/ 4.1.1 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2024
Resolution: Received Class Survey attesting to sat repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 March 2024 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design of construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to moving parts, which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed excessive FO leak from #1 FO pump. 74SOLAS(20) II-1/ 26.1 40abc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 October 2025
Resolution: Received, reviewed and accepted class report NKK - attached.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 March 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed excessive amounts of FO leaking from the #1, #2 and #3 Generator cylinder covers. 74SOLAS(20) II-2/4.1.1 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2024
Resolution: Received Class Survey attesting to sat repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 15 March 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammabel liquids. PSCO observed fuel soaked lagging on the #1 FO purifier pump. 74SOLAS(20) II-2/4.1.1 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2024
Resolution: Received Class Survey attesting to sat repairs.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 March 2024 Resolved
Fixed local application fire-extinguishing systems are to protect areas such as the following without the necessity of engine shutdown, personnel evacuation, or sealing of the spaces: the fire hazard portions of internal combustion machinery. PSCO was notified of inoperable hyper water mist system over the M.E. 74SOLAS(20) II-2/ 10.5.6.3.1 40abc
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 October 2025
Resolution: Received, reviewed and accepted Class report NKK - attached.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 10 May 2022 Resolved
Discharge into the sea of food wastes as far as practicable from the nearest land, but not less than 12 nautical miles from the nearest land or the nearest ice shelf. Food wastes shall be comminuted or ground. PSCO observed numerous discharges of food wastes within the Gulf of Mexico special are prior to entry in Mississippi River. Vessel cannot provide evidence of being able to comminute garbage to MARPOL standards. MARPOL 73/78 Annex V/6.1.1 16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 12 May 2022
Resolution: PSC NOLA received a class report from NKK satisfying the requirement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 May 2022 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a leak at the gasket between the fuel line and high pressure fuel pump on the #2 Auxiliary Engine. Vessel is not authorized to operate #2 Auxiliary Engine, while in port until fixed. 74 SOLAS (20) II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2022
Resolved 12 May 2022
Resolution: PSC NOLA received a class report from NKK satisfying the requirement
Fire Fighting › Self-contained Breathing Apparatus › Valve
Issued 29 November 2016 Resolved
Fire protection systems and fire-fighting systems and appliances shhall be maintained ready for use. PSCO observed multiple SCBAs not operational. Document of Compliance for carrigae of dangerous goods requires 04 SCBAs and only 02 SCBAs were operational. SOLAS 74 (14 cons) Ch. II-2 Reg. 14.1.1 (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 November 2016
Resolved 16 August 2017
Resolution: RECEIVED SURVEY REPORT RECTIFYING DEFICIENCY, PLACED IN DOCS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.