MAURY USCG vessel records
← All vessels

VANQUISH

VANQUISH is a public freight. The Coast Guard has recorded 24 inspections since 2016, most recently in April 2025, along with 23 deficiencies and 5 operational controls.

Records from 2016 to 2025. Most recent: inspection, 16 April 2025.

Built
Not recorded
Last inspected
16 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 April 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9375135
1381470
Flag
NETHERLANDS
Maury page id
psix-1381470

Documentation record

Tonnage as PSIX records it3871 - Convention (Subpart B), Gross Ton
1427 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

16 April 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8112584
5 October 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7803171
10 April 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7665927
31 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7660255
14 March 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7650776
14 March 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7719332
18 November 2022 Appeal
Administrative · Commandant (CG-CVC) · Activity 7598970
2 November 2022 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7587910
14 October 2022 PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7575960
7 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7573325
7 October 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611315
25 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7458847
23 November 2021 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7356306
10 November 2021 PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7348188
17 November 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7094675
7 May 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6678034
5 April 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6656573
11 October 2018 ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559434
29 March 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6380966
7 February 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6350914
29 January 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6079168
10 January 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068617
14 December 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6058222
23 March 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5838674

Deficiency record · 23

01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 31 March 2023 Resolved
An International Oil Pollution Prevention Certificate shall be issued, after an initial or renewal survey in accordance with the provisions of regulation 6 of this annex...Vessel's IOPP Certificate Form A indicates vessel's oil content meter is a MEPC.60(33). However, vessel is equipped with an approved MEPC.107(49) oil content meter. MARPOL (17 CONS.) ANNEX I / REG 7.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 10 April 2023
Resolution: Vessel agent submitted new class report performed by class BV. and new IOPP certificate showinf vessel is equiped with 107(49) OCM.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 October 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and with any additional requirements, which may be established by the company. Due to the objective evidence in the identified deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM Code. PSCOs collected objective evidence that the crew is unaware of operating key systems onboard, specifically the oily water separator. While onboard, operation of the oily water separator could not be verified to the PSCOs. Furthermore, PSCO’s observed a systematic failure of required fire and lifesaving equipment onboard the vessel. An external audit conducted by the Flag is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74 SOLAS (20 Cons.) IX/3.1 ISM Code A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 October 2022 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCOs observed excessive amounts of fuel oil and oil on the bilge tank tops and throughout the engine room, posing a fire risk to the ship and crew. 74 SOLAS (04 CONS) II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 October 2022 Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel, and shall be large enough to accommodate easily the normal drainage during the unattended period. All bilge alarms are found to be inoperative in the engine room. 74 SOLAS (04 CONS) II-1/48.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 October 2022 Resolved
In cargo ships, the failure of such gauges or over?lling of the tank shall not permit release of fuel into the space. The use of cylindrical gauge glasses is prohibited. The Administration may permit the use of oil-level gauges with ?at glasses and self-closing valves between the gauges and fuel tanks. PSCOs observed a self-closing valve between a day tank located in purifier room and the associated sight glass permanently held in the open position by safety wire. 74 SOLAS (04 CONS) II-2/4.2.2.3.5.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 October 2022 Resolved
With a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure, either by remote starting of one of the main fire pumps with remote starting from the navigation bridge and fire control station, if any, or permanent pressurization of the fire main system by one of the main fire pumps. The emergency fire pump is inoperable and main fire pump is being used for HVAC cooling and cannot sufficiently supply required pressure to fire main system. 74 SOLAS (04 CONS) II-2/10.2.1.2.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 October 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Fire doors in located on the Tween Deck in the engine room do not close properly to provide the required class boundary. Furthermore, all self-closing fire doors forming a required fire boundary within the accommodation stair well were found modified with permanently or temporarily affixed holdbacks, which are not an approved installation in accordance with the fire plan. 74 SOLAS (04 CONS) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 2 November 2022
Resolution: PSCO observed door closing. Deficiency is rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2022 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. PSCOs observed inoperable emergency lighting at the davit launched liferaft and below the freefall lifeboat. 74 SOLAS (20 CONS) III/16.7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 October 2022 Resolved
Any ship of 400 gross tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. Engineering staff, including the Chief Engineer, could not demonstrate to PSCOs proper operation of the vessel’s oil water separator, and there was no proof available that the OWS was working properly. MARPOL (2017 CONS) Annex I / Reg. 14.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2022 Resolved
Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. PSCOs discovered a high-pressure fuel line connection support bracket had a broken weld and the fuel line was supported by a rope from the overhead. Under the high-pressure fuel line, a drip pan was found with fuel oil collected from an evidential leak from the high-pressure fuel line. 74 SOLAS (04 CONS) II-2/4.2.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 October 2022 Resolved
Ships shall be provided with fire hoses, the number and diameter of which shall be to the satisfaction to the administration. PSCOs observed a fire hose missing from the forecastle storage in accordance with the approved fire plan. 74 SOLAS (04 CONS) II-2/10.2.3.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 October 2022 Resolved
The lines shall be painted in white or yellow on a dark ground or in black on a light ground. The marks should be plainly visible. The deck line for the vessel’s load line was undistinguishable due to being painted the same color as the hull. ILLC 8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 October 2022
Resolution: PSCOs observed correction of deficiency during deficiency check conducted on 17Oct2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Duty PSCO was notified that vessel lost its bow thruster and that this equipment is inoperable. 74 SOLAS (20 cons.) Ch. I / Reg 11.a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 15 June 2022
Resolution: Vessel submitted class report showing that the bow thruster has been repaired and is now fully operational.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 November 2021 Resolved
All fire dampers shall be capable of manual operation. Fire damper in oil purifier room was not capable of manual operation. Ventilation can be secured but "A" Class boundary cannot be set. 74SOLAS(20)II-2/9.7.3.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2021
Resolved 10 November 2021
Resolution: Crew conducted repairs. Test Sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 November 2021 Resolved
Any ship of 400 gross tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment. Oily water separator was inoperable, SMS notifications were made but neither flag or class were notified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2021
Resolved 23 November 2021
Resolution: Faulty part identified, ordered and installed. Class surveyors and PSCO's witnessed satisfactory operation of OWS equipment. Class survey report included in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 May 2019 Resolved
Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Rescue boat davit brake is currently being serviced and is not operational. 74SOLAS(14) III/20.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2019
Resolution: Class attestation to repair and testing of davit operation witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 May 2019 Resolved
Every inflatable liferaft shall be serviced at intervals not to exceed 12 months, provided where in any case this is impracticable the administraion may extend this period to 17 months. Inflatable liferafts are past service date of April 2019. Vessel has no proof of extension from the administration. 74SOLAS(14)III/20.8.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2019
Resolution: Rental Liferafts placed onboard during liferaft servicing attested by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 May 2019 Resolved
Doors in "A" Class divisions shall be so contructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. Door sin "A" Class divisions leading to the engine room, Provision Store, and laundry space had cutouts in frame that would allow passage of smoke and flame. 74SOLAS(14)II-2/3.2.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2019
Resolution: Door frame pockets fabricated and installed to class satisfaction.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 29 March 2018 Resolved
9900-Other (not clearly hazardous)- Each loading arm and each transfer pipe-system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel has not conducted required annual pressure test of transfer pipes- 33CFR156.170(c)(4)
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 29 March 2018
Resolved 3 April 2018
Resolution: Test report sent in for liquid pressure test on transfer pipe for the vessel.
Communications › Radio Communications › EPIRB
Issued 30 January 2017 Resolved
1671 - RADIO - THE ADMIN SHALL ENSURE THAT THE RADIO EQUIPMENT IS MAINTAINED. EPIRB BATTERY ONBOARD HAS BEEN EXPIRED SINCE DECEMBER 2016. 74SOLAS(2014 CONS) IV/15.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: Received satisfactory class report.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 January 2017 Resolved
0670 - LSA - AT LEAST 3 VHFS SHALL BE PROVIDED AND CONFORM TO PERFORMANCE STANDARDS. ALL 3 BATTERIES FOR VHF WERE EXPIRED. 74SOLAS(2014 CONS) III/6.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: Received satisfactory class report.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 29 January 2017 Resolved
0699 - LIFESAVING - AT LEAST ONE SART SHALL BE CARRIED ON EACH SIDE OF EACH CARGO SHIP 500 GROSS TONNAGE AND ABOVE TO CONFORM WITH STANDARDS FROM THE ORGANIZATION. BOTH SART BATTERIES ON BOARD HAVE BEEN EXPIRED SINCE DECEMBER 2016. 74SOLAS(2014 CONS) III/6.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: Received satisfactory class report.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 23 March 2016 Resolved
1599-To assist in casualty investigations, ships, when engaged on international voyages, shall be fitted with a voyage data recorder as follows: ships of 3,000 gross tonnage and upwards constructed on or after 01JUL2002. Vessel's VDR is giving an error message. 74SOLAS(14)Ch.V/Reg.20/1.4
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 23 March 2016
Resolution: Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.