MAURY USCG vessel records
← All vessels

GET OVER IT

GET OVER IT is a 2016 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in May 2026, along with 23 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 19 May 2026.

Built
2016
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK9325
1381736
Flag
UNITED STATES
Maury page id
psix-1381736

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2016–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 27

19 May 2026 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8376786
1 May 2026 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8349501
21 May 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8141836
28 February 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8079772
11 July 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7956183
5 February 2024 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7853654
18 May 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7691958
30 August 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7546317
7 June 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7470659
31 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7301715
21 May 2021 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7205405
7 October 2020 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7073307
6 August 2020 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7036070
25 June 2020 Deficiency Check · In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6990192
8 June 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6971472
17 April 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6940420
11 February 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6906799
14 March 2019 In-Service Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6642246
26 November 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6586387
7 November 2018 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 6579902
24 May 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6422528
25 April 2018 Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6399210
29 August 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6254442
18 April 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6127584
23 June 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5916570
20 May 2016 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5882012
4 March 2016 Hull Examination · Internal Structural Exam · Initial Certification · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5829128

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2026 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment ate suitable for the service in which they are to be employed. Vessel must undergo sea trials after replacement and installation of cutlass bearing, to the satisfaction of the attending CG marine inspector. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Went underway outside of Kewalo Basin into the channel at full speed ahead, and did complete figure-8 turn. Upon mooring at the pier, inspected engine compartment for any sign of leakage. All was found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in A machinery space bilge. The visual alarm of the aft bilge high water level is non-functional. Repair the visual alarm to the satisfaction of the attending Marine Inspector. Crew shall check the machinery space for bilge water level every 30 minutes during vessel's operation. 46 CFR 182.530(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 12 March 2025
Resolution: Vessel operator provided adequate video evidence of operational test of bilge high water level alarm.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 February 2024 Resolved
Provision must be made for closing all supply ducts and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Two closure devices were missing some button hardware for securing them over the ducts. Repair or replace covers to the satisfaction of the attending marine inspector. 46 CFR 182.460(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 12 February 2024
Resolution: All hardware on the vent covers has been replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2022 Resolved
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Replace visual indication for high level bilge alarms. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2022
Resolution: Photos received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2022 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Replace retroreflective tape on 01 child lifejacket. 46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2022
Resolution: Photos received.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 21 May 2021 Resolved
Vessel is single screw, has auxiliary means of steering in the event of failure of the hydraulic system, but lacked the necessary tools to ensure the system properly functions. Provide tools and perform a functional test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 2 June 2021
Resolution: Tools provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2021 Resolved
Vessel lacks floating waterlight and may operate past daytime or at other times of restricted visibility. Provide waterlight or request restricted routes and conditions from cognizant OCMI.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 2 June 2021
Resolution: Restricted to daylight ops per owner's request.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2020 Resolved
Vessel required to carry/provide proper type/qty of visual distress signals for assigned route. Vessel failed to carry/provide proper qty/type of VDS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified carriage of proper type/qty of flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2020 Resolved
Vessel required to carry serviceable ring life buoy. Vessels existing ring life buoy grab line was deteriorated, rescue line was not the proper type/length, vessels name (markings) were missing and no retro-reflective markings were installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified renewal of ring life buoy, markings, and rescue line.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 26 June 2020
Resolution: O/O provided current/up to date FCC Radio Station Authorization for subject vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020 Resolved
Vessel required to be equipped with operable navigational lights IAW USCG Navigational Rules. Vessel missing all around white light.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2020
Resolution: O/O provided objective evidence of an operable all around (white) navigational light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020 Resolved
Vessel is required to be fitted with operable emergency fuel shut-off valves, properly labeled with operating instructions. Vessels emergency fuel shut off valves were not marked with operating instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified posting of emergency instructions for fuel shut-off valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2020 Resolved
Vessel is required to be outfitted with at least two portable lights. Vessel is not equipped with portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified carriage of two portable lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2020 Resolved
Vessels crew required to be enrolled in an approved consortium. O/O failed to provide current/up to date proof of enrollment in an approved consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2020
Resolution: Attending Inspector(s) reviewed current proof of enrollment letter for maritime consortium.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020 Resolved
Vessel required to be fitted with at least three fire buckets w/lanyard/markings. Vessel is not equipped with proper size/type fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2020
Resolution: Attending Inspector(s) received objective evidence that the vessel was equipped with proper type/qty of fire buckets.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 June 2020 Resolved
Vessel required to be fitted with audible/visual indicators for bilge high water alarms. Vessels visual indicator for fwd bilge high water alarm (belly hatch) was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified operation of bilge high water alarm indicators.
Communications › Radio Communications › EPIRB
Issued 7 May 2018 Resolved
EPIRB hydrostatic release expired; renew hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 24 May 2018
Resolution: Procured and installed new hydrostatic release; marked item with correct expiration date following installation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2016 Resolved
Ring Buoy was missing retro reflective tape and waterlight. Add retro tape on four sides on front and back and add water light with 3-6 foot lanyard and corrosion resistant clip. Vessel limited to daytime operations until resolved.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 21 June 2016
Resolution: Waterlight and retro reflective tape was added to ring buoy.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 May 2016 Resolved
Vessel missing ventilation covers for machinery space. Obtain covers, as discussed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 21 June 2016
Resolution: Added ventilation covers for machinery space.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2016 Resolved
Vessel missing radio instructions at operating station. Obtain instructions and post.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 21 June 2016
Resolution: Radio instructions were placed at operating station.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016 Resolved
Vessel missing approved first aid kit or equipment. Either obtain approved kit or add missing items to existing kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 21 June 2016
Resolution: Replaced first aid kit.
Personnel › Training › Familiarization Training
Issued 16 May 2016 Resolved
Owner/Operator of vessel must conduct new to zone inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2016
Resolved 31 May 2016
Resolution: Vessel conducted New to Zone COI Inspection on this date.
Personnel › Training › Familiarization Training
Issued 16 May 2016 Resolved
Owner/Operator of vessel must complete work-list dated 5/13/2016 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2016
Resolved 31 May 2016
Resolution: Work-list items were checked.

Casualty record · 1

29 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 6254442
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.