← All vessels
STAR COPENHAGEN
STAR COPENHAGEN is a 2015 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in April 2025, along with 10 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 24 April 2025.
- Built
- 2015
- Last inspected
- 24 April 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9699359 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5LSC7
1381863
Flag
LIBERIA
—
Maury page id
psix-1381863
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2016–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it63495 - Dead Weight, Metric Ton
75196 - Displacement, Metric Ton
36474 - Convention (Subpart B), Gross Ton
21603 - Convention (Subpart B), Net Ton
75196 - Displacement, Metric Ton
36474 - Convention (Subpart B), Gross Ton
21603 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
24 April 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8115275
19 April 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8115304
12 July 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7735575
6 January 2023
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7617643
12 July 2021
Appeal
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7253841
1 June 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7219407
30 May 2021
PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7210048
24 May 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6419970
26 April 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6111791
17 October 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6023807
17 October 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6023840
1 April 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5840533
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2023
Resolved
Fire protection system and fire fighting systems and appliances shall be maintained ready for use. PSCO oberved (1) Zone 6, cable/short circut fault on the fire dection system on the bridge.
(2) PSCO observed no power to the engine room alarm panel in the engine control room.
(3) PSCO observed no power to the CO2 alarm relay box in the CO2 room. 74 SOLAS 2020, II-2/14.1, 60ac
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 12 July 2023
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch material, except as provided in reg 14(2). such covers shall be weathertight and fitted with gaskets and clamping devices. PSCO observed multiple ventilation hatches dogs missing on the watertight hatches on deck and cargo ventilation hatches. A requirement was issued to provide a class report attesting to the replacement of the missing dogs on all cargo ventilation covers and watertight hatches on deck prior to departure. ICLL 66/88 Annex I/16.1, 17ac
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 July 2023
Resolved
The GMP shall also designate the person or persons in charge of carrying out the plan. C/O stated he is in charge of the plan but could not show where it was documented in GMP. MARPOL Annex V 10.2, 40ac
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 July 2023
Resolved
The GMP shall provide written procedures for minimizing, collecting, storing, processing, and disposing of garbage, including the use of the equipment onboard. Vessel GMP does not list the processing equipment or address the use of onboard equipment. MARPOL Annex V 10.2, 40ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met, 3. the limitability of combustible materials shall be restricted. PSCO observed excessive oil and oily rags in the bilge beneath #3 generator. A requirement was issued to provide a class report attesting to the removeable of the oil/oily rags under the generator prior to departure. 74SOLAS 2020, II-2/4.1.3, 17ac
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 12 July 2023
Resolved
In addition, test and inspections shall be conducted to determine the service ability of all protective enclosures and devices fitted to the location. PSCO observed a fault reading “channel 11” on the VDR. A restriction was issued to provide a class report attesting to a fully operational VDR with no alarms. 74SOLAS2020 V/18.8, 17ac
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2023
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 3 June 2021
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 29 out of 32 immersion suits are unserviceable due to unsealed seams. 74 SOLAS (20) III/20.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 June 2021
Resolved
The company and the ship shall comply with the requirements of the international Safety Management Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. 29/32 immersion suits were unserviceable and not identified by the ship's crew during monthly checks. In addition, fire extinguishers in engine room were not checked during the month of May. Require audit of SMS within 90 days.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 April 2017
Resolved
1730- Oily-water seperating equipment- Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with alarm arrangements to indicate when the level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is auto-stopped. Crew could not prove proper operation of oily-water seperator- MARPOL I/14.7
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.