Records in 2016. Most recent: inspection, 15 April 2016.
Inspection history · 7
15 April 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5854920
5 April 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5842093
1 April 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5845559
1 April 2016
COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5845623
1 April 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5845626
1 April 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5856876
28 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5842170
Electrical › Electric Generation Source (service) › Number of Sources
Issued 5 April 2016
Resolved
1430-AUXILIARY ENGINES-[name withheld] THE #1 & #3 SSDG'S TO BE OUT OF SERVICE WITH NO DISPENSATION FROM FLAG. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION OF THE #1 & #3 SSDG'S PRIOR TO MOVEMENT-60a-SOLAS II-1/41
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating #1 SSDG was repaired with spare parts and tested satisfactorily with electrical load in parallel with #2 SSDG. Vessel was issued a dispensation from Flag to operate without #3 SSDG until 04JUN16.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 5 April 2016
Resolved
0725-FIXED FIRE EXTINGUISHING-[name withheld] HOSES BETWEEN CO2 TANKS AND CO2 MANIFOLD TO BE DRY ROTTED. PROVIDE CLASS REPORT ATTESTING TO INSTALLATION PRIOR TO MOVEMENT-60a-SOLAS II-2/14.2.1.2
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating new CO2 hoses have ben procured from shore company and they have been installed by same shore side company.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 April 2016
Resolved
0710-FIRE PREVENTION-[name withheld] OPERATING THE EDG QUICK CLOSING VALVE TO BE PARTED, RENDERING THE VALVE INOPERABLE FROM OUTSIDE THE SPACE. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION PRIOR TO MOVEMENT-60a-SOLAS II-2/4.2.2.3.4
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating ships crew installed new cable and assembly was tested satisfactorily by class surveyor.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 5 April 2016
Resolved
0610-LIFEBOATS-[name withheld] LIFEBOAT WAS ONLY ABLE TO START THE ENGIONE WHEN BOTH BATTERIES ARE IN PARALLEL. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION OF BOTH BATTERIES ON INDIVIDUAL STARTING CIRCUITS-17a-SOLAS III/34 LSA CODE 4.4.6.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating two new batteries were procured and installed. Both starting circuits were tested satisfactorily by class surveyor.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 April 2016
Resolved
0715-DETECTION-[name withheld] OVER #2SSDG COVERED WITH A PLASTIC BAG, RENDERING IT INOPERABLE. WHEN BAG WAS REMOVED DETECTOR WOULD NOT OPERATE WHEN TESTED. UPON CLEANING, DETECTOR WAS ABLE TO OPERATE. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION OF FIRE DETECTION SYSTEM-17a-SOLAS II-2/7.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating fixed fire detection system was tested satisfactorily.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 5 April 2016
Resolved
1410-PROPULSION MAIN ENGINE-[name withheld] LEAKS ON THE MAIN ENGINE CYLINDERS #1 & #7. PROVIDE CLASS REPORT UPON COMPLETION OF REPAIRS-16a-SOLAS I/11
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating cylinders #1 & #7 were overhauled by ships crew and tested satisfactorily by class surveyor.
Communications › Radio Communications › Emergency Source of Power
Issued 5 April 2016
Resolved
1677-RESERVE SOURCES OF ENERGY-[name withheld] BOUGHT BATTERY CHARGERS IN THE GMDSS BATTERY ROOM WITH POWER CABLES LEADING OUT OF SPACE AND WIRED INTO AN ELECTRICAL FIXTURE IN AN ADJACENT SPACE. PROVIDE CLARIFICATION & ATTESTATION TO OPERATIONAL SAFETY FROM CLASS-16a-SOLAS IV/13.1
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: Received, reviewed and accepted clas report from RINA stating new GMDSS battery charger has been installed and tested satisfactorily.
Construction/Loadline › Structures › Door
Issued 5 April 2016
Resolved
1270-DOORS-[name withheld] ROOM DOOR WAS REMOVED AND NOT IN PLACE. PROVIDE CLASS REPORT ATTESTING TO REPAIRS-16a-SOLAS I/11
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 25 April 2016
Resolution: Received, reviewed and accepted class report from RINA stating new door has been installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016
Resolved
0950-ELEC EQUIPMENT IN GENERAL-[name withheld] JUNCTION BOXES INSTALLED BY THE CREW THAT WERE NOT INSTALLED IAW ORIGINAL DESIGN OF VESSEL. PROVIDE REPORT FROM CLASS ATTESTING TO INSTALLATIONS-16a-SOLAS I/11
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating all junction boxes were repaired satisfactorily.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 5 April 2016
Resolved
1740-OIL DISCHARGE MONITOR SYSTEM-ENGINEERING DEPT DID NOT KNOW HOW TO RECALL INFORMATION FROM THE OIL CONTENT METER MEMORY. PROVIDE CORRECTIVE ACTION PLAN FROM COMPANY WITH CONCURRENCE FROM FLAG-40b-MARPOL I/11 MEPC 107(49)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating training was conducted for engineering department and engineering officers were able to succesfully obtain recoreded data from OCM.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 5 April 2016
Resolved
0199-OTHER-C/E WAS UNABLE TO PROVIDE SUITABLE TRANSFER PROCEDURES. PROVIDE TRANSFER PROCEDURES PRIOR TO CONDUCTING BUNKERING OPERATIONS-c-33CFR155.720
Action required: 703 - Prior to bunkering operations
Due 5 April 2016
Resolved 8 April 2016
Resolution: Received, reviewed and accepted approved transfer procedures for bunkering.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 April 2016
Resolved
0899-OTHER ACCIDENT PREVENTION-C/E WAS UNABLE TO PROVIDE RECORDS OF BUNKER LINE HYDROSTATIC TESTING. PROVIDE DOCUMENTATION ATTESTING TO LIQUID HYDROSTATIC TESTING OF BUNKER TRANSFER PIPING PRIOR TO BUNKERING OPERATIONS IN THE UNITED STATES-c-33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 5 April 2016
Resolved 8 April 2016
Resolution: Received, reviewed and accepted documentation stating hydrostatic test was completed.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 5 April 2016
Resolved
2560-COMPANY VERIFICATION-DUE TO ABOVE LISTED DEFICIENCIES, REQUEST COMPANY CONDUCT AN INTERNAL ISM AUDIT-17a-SOLAS IX/5 ISM CODE 12.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2016
Resolved 14 April 2016
Resolution: Received class report from RINA stating company supervisor conducted internal audit.