MAURY USCG vessel records
← All vessels

QE IV

QE IV is a 2016 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2018, most recently in August 2025, along with 50 deficiencies and 4 casualty investigations between 2019 and 2023.

Records from 2018 to 2025. Most recent: inspection, 19 August 2025.

Built
2016
Last inspected
19 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI9445
1382354
Flag
UNITED STATES
Maury page id
psix-1382354

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)98.4 ft × 16.7 ft × 6.6 ft
Registered tonnagegross 49 / net 21
ITC dimensions (L × B × D)98.4 ft × 16.7 ft × 6.6 ft
ITC tonnagegross 49 / net 21
BuilderGOLD COAST YACHTS INC · ST CROIX, VI, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portCHRISTIANSTED, VI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Convention (Subpart B), Gross Ton
21 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 30

19 August 2025 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8213822
22 July 2025 DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8192368
12 July 2025 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8183831
10 June 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8156162
3 June 2025 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8150618
1 April 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8103482
17 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7936515
19 April 2024 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7898416
19 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7882056
6 July 2023 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7734416
23 May 2023 Administrative Inspection · Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7655047
21 April 2023 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7673737
21 April 2023 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7673770
15 March 2023 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7651329
8 March 2023 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7690040
7 March 2023 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7647237
29 March 2022 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7420482
22 March 2022 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7404887
23 June 2021 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7233460
25 February 2021 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7146946
11 September 2020 In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7055829
23 June 2020 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6983785
12 February 2020 Administrative Inspection · Examination of Repairs
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6908069
11 February 2020 Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6906804
30 September 2019 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6829575
26 June 2019 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6726044
20 June 2019 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6720983
18 June 2019 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6721165
12 February 2019 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6624198
10 October 2018 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6555599

Deficiency record · 50

18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 July 2025 Resolved
A marine employer shall comply with the chemical testing requirements found in 46 CFR Subpart 4.06. During a DAPI audit conducted this day, the company was found to be lacking many items from its drug and alcohol policy.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2025
Resolved 19 September 2025
Resolution: The finalized plan has been received by the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The port fuel shutoff valve was unable to fully close using the pull cable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Prior to the end of the inspection, crewmembers were able to successfully close the shutoff valve.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 June 2025 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The vessel's IBA was lashed down to the cradle and would have been unable to float free.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Prior to the end of the inspection, the captain removed the lashings that had secured the IBA to the cradle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The vessel's fire pump could only provide water pressure to approximately 48 psi.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 24 June 2025
Resolution: Vessel crew conducted a satisfactory test of the vessel's newly-installed fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 June 2025 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation. Insulation is either missing from or loose on the overhead in the port and starboard engine spaces.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: New insualtion has been installed in the port and starboard engine rooms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that the pump is permanently mounted. The bilge pump in the starboard generator space was found to be loose and not mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 26 August 2025
Resolution: The bilge pump has been mounted in the space.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Dead end or loose wiring was noted in the starboard generator space and aft passenger space near the restrooms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 15 July 2025
Resolution: The noted wires have been closed off and areas of the overhead sealed off.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2025 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. The battery in the port generator space was found to have terminal corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 8 July 2025
Resolution: The battery terminal was noted to be clean and covered.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2025 Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The port and starboard engine and generator hatches were not fitted with attachment devices.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: Hatch stays have been installed on the port and starboard generator and engine room space hatches.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2025 Resolved
A power-driven vessel underway shall exhibit sidelights and a stern light. The vessel's port side and stern navigational lights were found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 24 June 2025
Resolution: The stern and port navigation lights are operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
Spanner wrenches must be provided where a 1.5 inch diameter fire hose is required. The amidships fire station was missing a spanner wrench.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 26 August 2025
Resolution: Two spanner wrenches have been provided on board the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 June 2025 Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06 and must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The vessel could not produce alcohol testing devices.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 29 August 2025
Resolution: The vessel now maintains three alcohol test strips on board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The vessel stores the lights in a container with distress signals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 24 June 2025
Resolution: Portable lights have been stowed in agreed-upon locations to meet the requirement.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 June 2025 Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication and tide tables. The U.S. Coast Pilot was not maintained on board and tide tables were found to be outdated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 21 July 2025
Resolution: Up-to-date tide tables and U.S. Coast Pilot are now maintained on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 3 September 2025
Resolution: Nick showed proof of newly-issued FCC permit.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 June 2025 Resolved
Abandon ship, man overboard, and fire fighting drills, conducted every three months, and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and a general description of the drill scenario and training topics. The vessel has logged infrequent drills with minimal details.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 21 July 2025
Resolution: The drills conducted on the day of the inspection have been documented in the vessel log.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 June 2025 Resolved
Each EPIRB must be tested monthly, which shall be logged or otherwise documented. Vessel representatives could not provide a log or documentation of EPIRB tests.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 24 June 2025
Resolution: EPIRB tests are being logged.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
The fire pump outlet must be fitted with a pressure gauge. A pressure gauge was not installed at the fire pump outlet.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 June 2025
Resolution: Corrected on the spot; a pressure gauge was installed at the outlet for the fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2025 Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter. Two of the vessel's three ring buoys have deteriorated grab lines.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2025
Resolution: Corrected on the spot; vessel representatives provided two new ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2025 Resolved
A vessel on a limited coastwise route must carry six hand red flare and six hand orange smoke distress signals. Nine of the vessel's distress signals were found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2025
Resolution: Corrected on the spot; vessel representatives provided full complement of valid distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2025 Resolved
A vessel must carry one floating waterlight. The light was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2025
Resolution: Corrected on the spot; vessel representatives provided a new water light for the ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2025 Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Stbd generator space is missing noncombustible insulation overhead on and around the hatch cover. 46 CFR 177.410(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 3 June 2025
Resolution: MI confirmed insulation installed in the overhead of the starboard generator space.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Starboard outdrive protection rail broke off. Replace as original. 46 CFR 176.802 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 19 August 2025
Resolution: The starboard outdrive protection was reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limits. Oil for engine drives were found with sea water intrusion. Must conduct sea trial in the presence of a Coast Guard Marine Inspector to clear deficiency. May not carry passengers until MI satisfied with underway survey.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2024
Resolved 26 April 2024
Resolution: Replaced engine drives in-kind. Conducted satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2023 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicated high water level in each of the following normally unmanned spaces. A Space with a non water tight closure, such as space with a non watertight hatch on the main deck. Attending MI's noted that of the 8 high bilge water alarm sending unites only two were correctly mounted. Prior to operations with passengers demonstrated proper operation of all bilge alarms as per the above requirements. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Attending MI observered proper operations of all 12 bilge alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2023 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following - Life jackets. Attending MI's noted that children life jackets were not located in the labeled areas. Relocate and ensure the amount matches the requirement of the vessels COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: MSD St. [name withheld] attended the vessel and verified that this item had been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 15 March 2023 Resolved
Attending MI's noted that the length of bolt on both port and std centerline mooring cleat's is inadequate. Replace with longer bolts. 46CFR184.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 6 July 2023
Resolution: Discussed with owner and builder will add special note and monitor def. at all inspections. Bolts are glassed into vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 March 2023 Resolved
The Certificate of Inspection must be posted under glass conspicuously where passenger observation is likely. 46CFR176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 March 2023
Resolution: MSD St. [name withheld] attended the vessel and verified that this item had been corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 March 2023 Resolved
Whenever damage to the hull is discovered that may affect the seaworthiness of a vessel, the cognizant OCMI may require the vessel to be taken out of service to effect repairs. Port side pontoon found with damage on stem allowing water ingress into collision bulkhead void space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2023
Resolution: Attended vessel and inspected repair. Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 February 2021 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Marine inspectors observed all (04) 15 person lifefloats were not in good working order. All (04) 15 person lifefloats had significant deterioration from weathering.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2021
Resolved 6 March 2021
Resolution: STX MI's verified IBA installation
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 June 2020 Resolved
Vessel not conducting/ logging drills
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 October 2019 Resolved
Lifefloat needs to be label with vessel name and passenger markings. 46 CFR 185.604(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 6 November 2019
Resolution: Labelled lifefloats
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 October 2019 Resolved
Lifefloat light not operational. Replace light. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 6 November 2019
Resolution: Replaced light
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019 Resolved
Install gauge at outlet of fire pump per approved drawing. 46 CFR 181.30(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 6 November 2019
Resolution: Installed gauge and tested pump. All was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019 Resolved
Vessel is required to have at least one water light attached to a ring buoy and be in operational condition.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 July 2019
Resolved 27 June 2019
Resolution: Attached and working
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 June 2019 Resolved
First aid items expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 26 June 2019
Resolution: Rectified during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 June 2019 Resolved
Stern light not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 7 August 2019
Resolution: Stern light was replaced and tested satisfactorily.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2019 Resolved
Bilge high water alarm in starboard side generator room did not work.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 July 2019
Resolved 27 June 2019
Resolution: Replaced alarm. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019 Resolved
Life ring required to have line attached that is not fraying.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 July 2019
Resolved 27 June 2019
Resolution: Replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2019 Resolved
Vessel is required to carry two life floats, but carries four. Three of the four are beyond useful service life and are required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 7 October 2019
Resolution: Vessel has installed new life floats
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 June 2019 Resolved
Vessel could not successfully recover Oscar. Vessel ran over Oscar first on the starboard side and then on the port side. Vessel uses a cargo net type of lifesaving appliance to recover people from the water. This was hooked up incorrectly first on the starboard side before being moved to the port side. Crew could still not recover Oscar and drill was aborted. Vessel crew to show attending MI that they can safely recover Oscar in a timely manner and to conduct other drills as necessary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Vessel succsessfully recovered MOB. Conducted Fire and abandon ship drills. All sat. However - vessels recovery system for MOB is in question as to its safety.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 June 2019 Resolved
Vessel currently pays user fees for a tank vessel not a passenger ship over 65ft. Vessel is currently underpaying user fees.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 7 October 2019
Resolution: Vessel has paid correct user fees of $600 and FINCEN has reclassified the vessel as a passenger vessel in lieu of a tank vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 June 2019 Resolved
Fuel/oil hose on top of the tank in the port side generator room is leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 7 August 2019
Resolution: Witnessed satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2019 Resolved
The port side main engine, on the port side forward is leaking raw water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 7 August 2019
Resolution: Witnessed satisfactory repair.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 June 2019 Resolved
Vessel did not have log books on board to prove required drills (MOB, Fire & abandon ship) were being conducted. Vessel required to provide logs to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Vessel provided logs, however vessel has not been conducting Fire drills or Abandom ship drills. The only drill being conducted is a MOB drill, but this was not completed every three months.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2019 Resolved
Required logs for documenting fire drills were not on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Vessel provided logs, but fire drills had not been logged or completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 October 2018 Resolved
Replace/repair gasket for engine room hatch on both port and stbd sides.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 November 2018
Resolved 10 October 2018
Resolution: Replaced engine room gaskets on both port and stbd sides.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 October 2018 Resolved
Provide a spanner wrench for fire main connection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 17 October 2018
Resolution: Spanner wrench provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 October 2018 Resolved
Fire main system required to be operational to 60psi. When energized the ppump could only reach 20 to 30 psi.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2018
Resolved 10 October 2018
Resolution: Vessels sea strainer was clogged. Cleared strainer and operationaly tested pump to 60psi.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 October 2018 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 10 October 2018
Resolution: Expired items replaced same day.

Casualty record · 4

18 June 2019Routine · role: Involved in a Marine Casualty · activity 6721165
30 June 2019Routine · role: Involved in a Marine Casualty · activity 6939691
8 March 2023Routine · role: Involved in a Marine Casualty · activity 7690040
21 April 2023Routine · role: Involved in a Marine Casualty · activity 7673770
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.