MAURY USCG vessel records
← All vessels

GROTON

GROTON is a 1987 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 17 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 14 May 2026.

Built
1987
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI8970
1382485
Flag
UNITED STATES
Maury page id
psix-1382485

Documentation record

Registered dimensions (L × B × D)39.9 ft × 11.8 ft × 5.4 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC. · ANAHEIM · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGROTON, CT
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

14 May 2026 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8356662
8 September 2025 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8212724
1 May 2025 Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8112916
28 April 2025 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8138928
18 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926334
28 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7787654
18 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7653820
3 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7516213
21 June 2021 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7197043
15 April 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7174492
22 September 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7063749
14 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6782538
4 February 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6619698
12 September 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6538977
24 October 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6294188
7 August 2017 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6233519
2 August 2017 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6229185
14 June 2016 Simplified Stability Test · Initial Certification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5906906

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 May 2026 Resolved
Engine did not restart in override position.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 9 July 2026
Resolution: Override function works satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2025 Resolved
Main engine unable to be started during inspection. Prove proper operation of main propulsion. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 September 2025 Resolved
Fireboy unable to be tested during inspection. Prove proper operation of Fireboy shut down and override. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 June 2024 Resolved
Vessel required 6 flares, one of the 6 was expired. Provide 6th flare.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2024
Resolved 1 July 2024
Resolution: all up to date
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 September 2023 Resolved
Vessel over 26' must have visual and audible alarm at the operating station to indicate high water level. Vessels bilge alarm did not work when tested. Prove proper operation of bilge high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2023
Resolved 17 April 2024
Resolution: operation successful, cleared def
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 3 August 2022 Resolved
No marine employer shall employ any individual to serve as crewmember unless the individual passes a chemical test for dangerous drugs for that employer. During a Drug & Alcohol Program Inspection spot check, it was determined that the deckhand who was in a random testing consortium was not subject to a random test for at least 60 days during the previous 185 days. Deckhand must receive a pre-employment chemical test for dangerous drugs prior to engaging as a crewmember.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 8 August 2022
Resolution: Marine Employer had satisfactory records of chemical testing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2019 Resolved
Label 3 Fire Buckets
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 21 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 August 2019 Resolved
Provide new line for water light attached to Ring Life Buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 21 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2019 Resolved
Replace cutlass bearing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 26 March 2019
Resolution: cutlass bearing replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 August 2017 Resolved
Provide servicing certificate for fixed fire system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 7 August 2017
Resolution: Pre-engineered system was serviced by approved servicing company and found satisfactory.
Fire Fighting › Fire Bucket › Quantity
Issued 2 August 2017 Resolved
Provide 1 fire bucket with line.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 7 August 2017
Resolution: Fire bucket was provided with appropriate stencil.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 June 2016 Resolved
Ensure all crewmemberrs are enrolled in DAPI program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2016
Resolved 1 July 2016
Resolution: Sighted DAPI program pre-employment tests and contract.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 June 2016 Resolved
Provide FCC certificate and Station License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 1 July 2016
Resolution: Sighted cert.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 June 2016 Resolved
Provide Charts, NTM, Light List and Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 1 July 2016
Resolution: sighted charts and pubs.
Communications › Audible Communications › Bell
Issued 14 June 2016 Resolved
Provide bell
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 1 July 2016
Resolution: bell on board
Operations/Management › Drills/Instruction › Safety Orientation
Issued 14 June 2016 Resolved
Demonstrate passenger safety orientation
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 1 July 2016
Resolution: heard sfety orientation
Lifesaving › Lifejacket/PFD (Type V) › Lights
Issued 14 June 2016 Resolved
Provide float light for life ring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 1 July 2016
Resolution: Float light on board

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.