MAURY USCG vessel records Sign in
← All vessels

JUDITH ANN

JUDITH ANN is a 2019 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2018, most recently in January 2026, along with 5 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 28 January 2026.

Built
2019
Last inspected
28 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9852614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDK5040
1382653
Flag
UNITED STATES
368061080
Maury page id
psix-1382653

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2018–2026)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)171.7 ft × 31.9 ft × 13.9 ft
Registered tonnagegross 99 / net 68
ITC dimensions (L × B × D)171.7 ft × 31.9 ft × 13.9 ft
ITC tonnagegross 497 / net 149
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2019
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portErath, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it497 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
149 - Convention (Subpart B), Net Ton
68 - Regulatory (Subpart C or D), Net Ton
0 - Simplified, Gross Ton
0 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK5040MMSI 368061080 · active · compulsorily equipped · granted 4 October 2018, expires 4 October 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

28 January 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8295261
8 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8130301
28 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8121629
20 February 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7862354
26 May 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7713852
6 April 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7664130
26 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7457312
15 June 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7226401
12 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7154631
3 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6966893
16 February 2018 Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6356266

Deficiency record · 5

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 June 2021 Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting system; Emergency lighting did not actuate upon failure of main power.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 June 2021
Resolution: Master fixed emergency lighting before inspection team left.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned machinery spaces;Steering compartment alarm inaudible.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 June 2021
Resolution: Master cleaned steering compartment bilge and retested audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2021 Resolved
A vessel at anchor shall exhibit where it can best be seen: In the fore part, an all-round white light or one ball; The anchor light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 16 June 2021
Resolution: Vessel rep installed new anchor light bulb.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2021 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either; a pressure type connector on each conductor; Dead-end wire was found coming from DP electrical room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 16 June 2021
Resolution: Vessel rep removed dead end wire from passenger area.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 15 June 2021 Resolved
The master or person in charge of a ship to which this section applies shall ensure that one or more placards are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers; MARPOL Placard was out of date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 16 June 2021
Resolution: Vessel rep provided updated version of MARPOL ANNEX V. 2018 version

Ownership record