TURTLE RUNNER

TURTLE RUNNER is a 2016 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in March 2026, along with 22 deficiencies and 3 casualty investigations between 2020 and 2026.

Records from 2016 to 2026. Most recent: inspection, 21 March 2026.

Built
2016
Last inspected
21 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ3031
1383496
Flag
UNITED STATES
Maury page id
psix-1383496

Documentation record

Registered dimensions (L × B × D)71.1 ft × 28.5 ft × 9.3 ft
Registered tonnagegross 94 / net 66
ITC dimensions (L × B × D)71.1 ft × 28.6 ft × 9.3 ft
ITC tonnageNot recorded
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portPENSACOLA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

21 March 2026 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8329580
20 March 2026 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8329663
4 June 2025 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8152322
4 June 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8162128
15 May 2025 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8113654
31 January 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8072813
24 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7918629
24 April 2024 Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900846
4 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7681807
20 January 2023 Administrative Inspection · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7625867
2 May 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7454765
27 September 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7321332
23 June 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7234149
8 October 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7073789
21 September 2020 Drydock Exam · Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7062524
31 August 2020 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7046853
14 August 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7033451
16 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7008866
27 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6944914
13 December 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6873509
6 November 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6850526
9 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6659142
1 March 2018 DAPI Audit · Examination of Repairs · Deficiency Check · Administrative Inspection · Initial Certification · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6364261
2 March 2016 Construction Oversight · Initial Certification · COI Inspection · Deadweight Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6052969

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 May 2024 Resolved
Each distribution panel and switchboard must be protected from dripping or splashing water. Marine Inspector observed no drip shield over panel inside Engine Room door, port side. Install.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 14 May 2024
Resolution: Vessel rep supplied satisfactory evidence of new drip shield.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 May 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Marine Inspector observed tapped butt connectors in cable run under the starboard wing control station. Install in enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 14 May 2024
Resolution: Vessel rep supplied satisfactory evidence of new junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023 Resolved
Electrical equipment used in a machinery space must be dripproof. Battery chargers in engine space missing drip cover. Install cover/shield to provide dripproof for all battery chargers on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 14 May 2023
Resolution: Drip covers installed on battery chargers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire and electrical shock. Open wires found under bridge wing control station. Remove wires or install junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 14 May 2023
Resolution: Open wires placed in junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2021 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Vessel has additional ring life buoy floating waterlight with an expired battery, replace battery or remove extra ring life buoy waterlight from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 30 June 2021
Resolution: Received documentary evidence of battery replacement for the waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired of replaced. Vessels ring life buoy on the upper deck has grab lines that are dry-rotted. Grab lines require replacement or replace entire ring life buoy with serviceable approved one.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 7 July 2021
Resolution: Received documentary evidence of lifebouy lifeline replacement.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 June 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessels charts were not up to date. Replace with new up-to-date charts or make chart corrections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 7 July 2021
Resolution: Received documentary evidence of the chart corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 June 2021 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.Replace expired items or entire first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 30 June 2021
Resolution: Received documentary evidence for the first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2021 Resolved
Valves for removing water or impurities from diesel fuel in water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Diesel fuel filter was missing drainage cap, replace missing caps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 7 July 2021
Resolution: Received documentary evidence of mechanical plugs in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 June 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel was missing both portable battery lights. Replace lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 7 July 2021
Resolution: Received documentary evidence of portable flashlights in the operating station and engine compartment.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 May 2021 Resolved
Prior to refloating or moving the vessel, you shall provide a salvage and transit plan for approval to [name withheld] approval you will be authorized to transit directly to Metal Shark in Bayou La Batre, AL for repairs. You must provide a damage assessment and repair proposal to the OCMI for approval before any repairs are made. Any deviation from this requirement must be coordinated with the OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 5 October 2020 Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about the vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a) prior to operating / carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: Repairs Complete
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 September 2020 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel does not have a valid COD. 46 CFR 67.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2021
Resolution: Vessel has valid COD
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 31 August 2020 Resolved
A ferry that carries more than 49 passengers on a rivers route not within one mile of land must be fitted with a FCC Type Accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station. Vessel reported radar malfunction.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2021
Resolution: Radar has been repalced with operable one.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2020 Resolved
Vessel's fwd life ring light had the incorrect type of battery. replace with approved type of battery for the light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: Submitted picture with approved battery
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2020 Resolved
Vessel did not have current corrected publications onboard. Provide evidence of current publications onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: submitted picture with approved and current publication printouts
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2020 Resolved
Vessel did not have covers on top of battery chargers in engine rooms. Provide protective covers for battery chargers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 3 June 2020
Resolution: Recieved pictures, all sat
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 May 2018 Resolved
All emergency drills and maneuvering drills must be completed in the presence of an inspector PRIOR to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2018
Resolution: Observed drills
Operations/Management › Drills/Instruction › Fire
Issued 3 January 2017 Resolved
Perform satisfactory fire drill with crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Resolved w/Sector Mobile.Activity #6364261.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 January 2017 Resolved
Perform satisfactory abandon ship drill with crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Resolved w/Sector Mobile. Activity #6364261.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 January 2017 Resolved
Perform satisfactory man overboard recovery drill with crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Resolved w/Sector Mobile. Activity #6364261.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 January 2017 Resolved
Provide proof of enrollment into a DAPI program for all crewmembers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2018
Resolution: Resolved w/Sector Mobile. Activity #6364261.

Casualty record · 3

8 October 2020Routine · role: Involved in a Marine Casualty · activity 7073789
4 June 2025Routine · role: Involved in a Marine Casualty · activity 8162128
20 March 2026Routine · role: Involved in a Marine Casualty · activity 8329663
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.