02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 December 2021
No resolution recorded
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. PSCO observed rotary steering gear leaking at the aft starboard side of the body and topplate mating surface.
74SOLAS(14) II-1/29.2.1
60a.c.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 December 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 December 2021
No resolution recorded
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed both steering gear motor controllers not able to have power secured as designed. The linkage from the external switch and the breaker was removed and power was secured only by unlocking the cabinet and using an adjustable wrench to change the breakers position.
74SOLAS(14)40.1.2
16a.c.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 1 December 2021
No resolution recorded
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed lagging soaked with fuel oil in many locations in particular the purifier room and lagging at the bottom of the HFO tanks and associated piping.
74SOLAS(14) II-1/26.1
50a.c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed stern tube oil seal tank quick closing valves secured open with wire rendering the valves not operational.
74SOLAS(14)1/11(a)
10c.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 1 December 2021
Resolved 1 December 2021
Resolution: PSCO observed vessel superintendent remove wire that caused valves to remain permanently open.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2021
No resolution recorded
When the fire-extinguishing medium is stored outside a protected space, it shall be stored in a room which is located behind the forward collision bulkhead, and is used for no other purposes. Any entrance to such a storage room shall preferably be from the open deck and shall be independent of the protected space. PSCO observed emergency generator CO2 room door will not close due to a warped door.
74SOLAS(14) II-2/10.4.3
40a.c.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 December 2021 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 November 2021
Resolved
In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO noted the vessel failed to report several non-conformities, per vessel's Safety Management System (SMS)procedures, of a technical and operational nature which collectively provide objective evidence of a serious failure or lack of effectiveness of the implementation of the ISM Code. Due to the failure or lack of effectiveness of the SMS, an external SMS audit shall be carried out.
74 SOLAS (20) IX/3.1
ISM CODE A/10.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 23 November 2021
Resolved 24 November 2021
Resolution: Vessel obtained Flag ISM Audit and additional Class survey.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaking from packing of quick closing valves for MDO storage tank and LSMGO #3 port side fuel tanks.
74 SOLAS (20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
Resolution: Replaced O-ring in valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed excessive accumulation and leakage of diesel fuel oil on no. 1 generator.
74 SOLAS (20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
Resolution: Replaced O-ring on two fuel pumps.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed significant leakage from no. 6 fuel injector on main engine.
74 SOLAS (20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
Resolution: Replaced O-ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed erratic pressure fluctuation and abnormal noise on no. 1 steering pump in comparison to no. 2 steering pump.
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
Resolution: Replaced shot bearing. Conducted steering test- satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive hydraulic leaks in windlass hydraulic system.
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
Resolution: Replaced gasket and several seals. Witnessed operational test with no leaks.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 November 2021
Resolved
The means for securing and maintaining weather tightness by other means than gaskets and clamping shall be to the satisfaction of the administration. PSCO observed at least one third of vessel cargo hatch cleats frozen.
ICLL (88) I/16(6)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2021
Resolved 24 November 2021
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed pinhole leak in gray water pipe near MSD.
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2021
Resolved 24 November 2021
Resolution: Class dispensation for 23Feb 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2021
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant corrosion of inlet and discharge sea water piping of outboard low temperature fresh water cooler.
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 December 2021 — due date passed with no resolution recorded
Resolution: Class dispensation for 23Feb2022.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant corrosion at the base of the deck and bulkhead of the fresh water tank.
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 November 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2021
Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in the normal manner. PSCO observed at least 04 pressure switches without covers, exposing wires.
74 SOLAS (20)II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 November 2021
Resolution: Covers installed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 April 2016
Resolved
A second source of energy shall be provided for an additional three starts. Emergency generator failed to start with secondary means.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received Letter of Dispensation from Flag state allowing vessel to depart without secondary means of starting emergency generator.