← All vessels
INCREDIBLE BLUE
INCREDIBLE BLUE is a 2011 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in January 2022, along with 17 deficiencies — 5 with no resolution recorded — and 2 operational controls.
Records from 2016 to 2022. Most recent: inspection, 5 January 2022.
- Built
- 2011
- Last inspected
- 5 January 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 5 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9452658 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8ZX9
1383520
Flag
LIBERIA
—
Maury page id
psix-1383520
Inspections, by type
…past their stated due date5
Years with a record
4 calendar years (2016–2022)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it57001 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
33036 - Convention (Subpart B), Gross Ton
19270 - Convention (Subpart B), Net Ton
67681 - Displacement, Metric Ton
33036 - Convention (Subpart B), Gross Ton
19270 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
5 January 2022
Appeal
Administrative · Commandant (CG-CVC) · Activity 7378245
1 December 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7356701
22 November 2021
ISM Exam · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7350526
14 November 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7350577
16 June 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7226735
10 June 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7221821
28 April 2020
Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6940790
6 April 2016
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5846113
Deficiency record · 17
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 December 2021
No resolution recorded
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. PSCO observed rotary steering gear leaking at the aft starboard side of the body and topplate mating surface.
74SOLAS(14) II-1/29.2.1
60a.c.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 December 2021
No resolution recorded
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed both steering gear motor controllers not able to have power secured as designed. The linkage from the external switch and the breaker was removed and power was secured only by unlocking the cabinet and using an adjustable wrench to change the breakers position.
74SOLAS(14)40.1.2
16a.c.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 1 December 2021
No resolution recorded
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed lagging soaked with fuel oil in many locations in particular the purifier room and lagging at the bottom of the HFO tanks and associated piping.
74SOLAS(14) II-1/26.1
50a.c.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed stern tube oil seal tank quick closing valves secured open with wire rendering the valves not operational.
74SOLAS(14)1/11(a)
10c.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2021
No resolution recorded
When the fire-extinguishing medium is stored outside a protected space, it shall be stored in a room which is located behind the forward collision bulkhead, and is used for no other purposes. Any entrance to such a storage room shall preferably be from the open deck and shall be independent of the protected space. PSCO observed emergency generator CO2 room door will not close due to a warped door.
74SOLAS(14) II-2/10.4.3
40a.c.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 November 2021
Resolved
In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO noted the vessel failed to report several non-conformities, per vessel's Safety Management System (SMS)procedures, of a technical and operational nature which collectively provide objective evidence of a serious failure or lack of effectiveness of the implementation of the ISM Code. Due to the failure or lack of effectiveness of the SMS, an external SMS audit shall be carried out.
74 SOLAS (20) IX/3.1
ISM CODE A/10.2.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaking from packing of quick closing valves for MDO storage tank and LSMGO #3 port side fuel tanks.
74 SOLAS (20) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed excessive accumulation and leakage of diesel fuel oil on no. 1 generator.
74 SOLAS (20)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2021
Resolved
The following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed significant leakage from no. 6 fuel injector on main engine.
74 SOLAS (20)II-2/4.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed erratic pressure fluctuation and abnormal noise on no. 1 steering pump in comparison to no. 2 steering pump.
74 SOLAS (20)I/11(a)
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive hydraulic leaks in windlass hydraulic system.
74 SOLAS (20)I/11(a)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 November 2021
Resolved
The means for securing and maintaining weather tightness by other means than gaskets and clamping shall be to the satisfaction of the administration. PSCO observed at least one third of vessel cargo hatch cleats frozen.
ICLL (88) I/16(6)
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed pinhole leak in gray water pipe near MSD.
74 SOLAS (20)I/11(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2021
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant corrosion of inlet and discharge sea water piping of outboard low temperature fresh water cooler.
74 SOLAS (20)I/11(a)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant corrosion at the base of the deck and bulkhead of the fresh water tank.
74 SOLAS (20)I/11(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2021
Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in the normal manner. PSCO observed at least 04 pressure switches without covers, exposing wires.
74 SOLAS (20)II-1/45.1.3
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 April 2016
Resolved
A second source of energy shall be provided for an additional three starts. Emergency generator failed to start with secondary means.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National