MAURY USCG vessel records
← All vessels

MARTI CARIBS

MARTI CARIBS is a freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in May 2026, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 20 May 2026.

Built
Not recorded
Last inspected
20 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9675834
1383938
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1383938

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2016–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it5055 - Convention (Subpart B), Net Ton
9932 - Convention (Subpart B), Gross Ton
13048 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 13

20 May 2026 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8377272
12 June 2025 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8157252
24 July 2024 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7965884
3 December 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7830385
13 May 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7449388
9 November 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7092443
13 May 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6681162
8 April 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6655134
18 November 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6309219
18 November 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6309238
21 June 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6182232
8 June 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6167473
11 May 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5873374

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 June 2025 Resolved
Inspection of life saving appliances shall be carried out monthly using he checklist required by regulation 36.1 to ensure that they are complete and in good order. PSCO observed immersion suit and embarkation ladder cover maintenance not being conducted in accordance with the maintenance plan. 74 SOLAS (20) III/20.7.2 Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 24 June 2025
Resolution: Received class statement attesting to proper implementation of maintenance plan.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 May 2022 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. During PSC examination, PSCO discovered that emergency generator was off and main starting batteries were missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: RO report received and uploaded to documents.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 May 2022 Resolved
With the exceptions noted in paragraph B of this section each NOA must contain all of the information items specified in table 160.206. Vessel failed to inform the local COTP that emergency generator was inoperable by primary means of starting. 33 CFR 160.206
Action required: 10 - Deficiency Rectified
Resolved 13 May 2022
Resolution: NOA violation, added for enforcement documentation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 April 2019 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fir safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: 1 fire protection systems and fire-fighting systems and appliances shall be maintained ready for use; and 2 fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. At least 09 high pressure CO2 rubber hose release lines have deteriorated due to friction with one another. The release hoses now show the inner metal braiding. 74SOLAS(14) II-2/14.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 13 May 2019
Resolution: class report and photographs received, system satisfactorily repaired
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 November 2017 Resolved
The vessel came into the port approximately 17 hours after submitting the ANOA for arrival into the port of San Juan, Puerto Rico in violation of 33 CFR 160.212(a)(4)(ii).
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 18 November 2017
Resolution: LOW accepted
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2017 Resolved
Not less than 1/2 of the total number of lifebuoys shall be provided with self-igniting lights complying with the requirements of paragraph 2.1.2 of the Code. PSCO found 02 malfunctioning lights for lifebuoys rendering them unsatisfactory for its intended purpose. 74SOLAS(2014) Ch. III/ Reg. 7.1.3. LSA Ch. II/Reg. 2.1.2.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 June 2017
Resolution: Ships crew replaced the two malfunctioning lights with ones in good working condition.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 June 2017 Resolved
Ships firefighter outfits do not fully protect personnel's face and neck areas posing as a hazard to its firefighters. 74SOLAS(2014 Ed.) Ch. II-2/ Reg. 10.1.1. FSS Ch. 3/reg.2.1.1.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2017
Resolution: Recieved proper documentation attesting to the purchase of Flash Hoods complying with the Code.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 8 June 2017 Resolved
The function of a fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature, or smoke, or aerosol particles... Ship does not posses means to test their slame detectors as per manufacturer standards. 74SOLAS(2014) Ch.II-2/ Reg. 7.3.2. 16ac
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 21 June 2017
Resolution: Recieved from vessel purchase invoice and pictures of test lamp from vessel.

Ownership record