MAURY USCG vessel records
← All vessels

SABRAGE

SABRAGE is a 2016 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in September 2025, along with 38 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 17 September 2025.

Built
2016
Last inspected
17 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ3300
1384118
Flag
UNITED STATES
Maury page id
psix-1384118

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 24.0 ft × 10.0 ft
Registered tonnagegross 48 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOPER MARINE INC · ST PETERSBURG, FL, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
39 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 25

17 September 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8236013
20 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8202064
24 September 2024 Drydock Exam · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7898138
5 September 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7784844
11 October 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7541385
23 August 2022 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7541403
25 October 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7339470
15 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7308285
3 May 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7188410
19 April 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7178576
2 September 2020 Deficiency Check · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7039022
6 May 2020 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6940088
22 October 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6838890
30 September 2019 Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6824789
12 June 2019 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6711720
8 May 2019 COI Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6678776
14 September 2018 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6540265
29 March 2018 DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6370495
26 January 2018 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6344159
28 October 2017 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6298923
3 April 2017 MTSA/ISPS Verification · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6116628
1 March 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6099555
6 February 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6083223
13 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6057106
13 May 2016 Deadweight Survey · Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5934274

Deficiency record · 38

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 August 2025 Resolved
Emergency radio broadcast placard was missing, replace with new permanently affixed placard in accordance with 46 CFR 184.510. 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 10 September 2025
Resolution: Placed E Broadcast placard onboard near the operating station.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 August 2025 Resolved
Vessel did not have radio telephony cert, receive and keep on board. Restricted to 1000' from shore.Vessel did not have radio telephony cert, receive and keep on board. Restricted to 1000' from shore. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 8 October 2025
Resolution: vsl received fcc certs for the radio
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 August 2025 Resolved
Captain and crew could not adequately communicate from topside to down below through one-way loud hailer, maintain 2-way radios for Captain to Deckhand communication while underway. 46 CFR 184.602e
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 10 September 2025
Resolution: Portable radio purchased and kept onboard to be used while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2025 Resolved
Bilge systems visual indicators did not light up when automatic bilge pump operated, repair visual indicators. 46 CFR 182.530c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 17 September 2025
Resolution: all visual and or audible indictor are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2025 Resolved
PFD storage in the bench seating on the bow of the vessel has deteriorated signage, replace 06 placards. 46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 10 September 2025
Resolution: Replaced old placards with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2025 Resolved
Retro reflective tape was found deteriorated on 11 adult type 1 PFD's, replace damaged retro. 46 CFR 180.71c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 5 November 2025
Resolution: life jacket retro was replace/ repaired wit solas tape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 20 August 2025 No resolution recorded
Vessel had no load mark or permanent draft marks, Install permanent marking prior to next credit drydock. 46 CFR 185.602(2)d
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 October 2024 Resolved
A vessel must provide with bilge pumps in accordance with Table 185.52(a). Owner/operator was unable to demonstrate proper operation of bilge pumps. Vessel limited to 49 passengers.
Action required: 705 - Other - as specified
Resolved 3 October 2024
Resolution: Witnessed statisfactory operation of the bilge/fire pumps.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 October 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: Updated charts and publications have been put on the VSL.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2024 Resolved
Prior to departing on a voyage, the passenger count must be communicated vergbally or in writing, and available ashore at the vessels normal berthing location or with a representative of the owner or managing operator of the vessel. The vessel does not communicate the passenger count ashore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: The operators now text passenger count information back to the office prior to each trip.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2024 Resolved
Provide life jacket donning placard for crew and passengers. Improper life jacket donning placard displayed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: Correct life jacket placard provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 October 2024 Resolved
Each ring life buoy must be marked with Type II retroflection material approved in 46 CFR 164.018. Retro reflective materilal is unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: New retro installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2024 Resolved
Vessel must provide a first-aid kit. Vessel had expired items in first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: First aid kit items renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2024 Resolved
The installation of fuel lines, must comply with the requirements of this paragraph. Shut off valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Starboard engine fuel shutoff valve did not close properly. Master performed maintenance and demonstrated satisfactory operation of starboard engine fuel shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 24 October 2024
Resolution: Master performed maintenance and demonstrated satisfactory operation of starboard engine fuel shutoff valve.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 September 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2023
Resolution: Master presented valid MMC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in a conspicuous place that are reguarly accesible and visible to crew and passengers. The life jacket donning placard installed was not for the correct type life jacket carried aboard the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2023
Resolution: Installed new placard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 September 2023 Resolved
An inflatable buoyant apparatus must be serviced at an approved facility annually. The IBA installed on vessel is expired. An IBA is not required but if installed on the vessel it needs to be in compliance with applicable regulations.
Action required: 10 - Deficiency Rectified
Resolved 5 September 2023
Resolution: Removed IBA from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 September 2023 Resolved
EAch hydrostatic release unit must be serviced every two years. EPIRB hydrostatic release unit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2023
Resolution: Installed new hydrostatic release unit.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2022 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed multiple inoperable high water level alarms at operating station. *Conduct rounds of #2 starboard compartment every 30 mins. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 15 October 2022
Resolved 17 October 2022
Resolution: Hi-Water alarms operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 October 2022 Resolved
The pump outlet must be fitted with a presuure gauge. Fire pump pressure gauge is inoperable. 46 CFR 181.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 30 November 2022
Resolution: Gauge installed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station. Midship port forward, port aft, and starboard aft holds high water bilge is inoperable. Make alarms audible at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
Resolution: Bilge alarms are operable; there was a fuse connection loose from routine maintenance conducted the week prior to inspection. Connections are tight and all alarms are operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021 Resolved
EAP training program: Supervisory personnel must receive at least 60 minutes of training. No supervisory EAP training proof or certificate on board. Provide proof of training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 14 October 2021
Resolution: Provided 60-minute EAP supervisory training certificate.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 September 2020 Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with §164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Port engine room missing a section of fire protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: Section of fire protection replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 September 2020 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Bracket at operating station rusted away.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: PVC bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 September 2020 Resolved
A vessel must carry one floating waterlight. Float light battery expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2020 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required. Spanner wrench missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: New one installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 September 2020 Resolved
Double hose clamping is required where practicable. Add clamps to bilge pumps flex hoses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: Added double clamps to all flex hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 September 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and protect passengers, crew, other persons, and the vessel. Remove dead-end wires in the port engine room aft of the engine, breaker box at the operating station missing dead end cover for to breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: Master covered exposed breakers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 September 2020 Resolved
Life jackets must be stored in convenient places distributed throughout accommodation spaces. Label compartments to reflect amount of life jackets stowed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 1 October 2020
Resolution: Life jackets were stored properly to reflect the amount in space.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 8 May 2019 Resolved
Provide updated Continuous Synapses Record (CSR).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Vessel provided updated copy of CSR.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 8 May 2019 Resolved
Complete SMS audit, make appropriate SMS amendments and submit for approval updated SMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Vessel completed SMS audit and made ammendments and submitted for approval.
01 - Certificates & Documentation › 013 - Documents › SAR co-operation plan for pass. ships on fixed trade
Issued 8 May 2019 Resolved
Complete SAR Coop Plan audit, make appropriate amendments and submit for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Vessel completed SAR COOP plan audit and submitted for approval.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 May 2019 Resolved
Provide and post emergency instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Vessel posted emergency instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2019 Resolved
Provide current drug and alcohol program roster.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2019
Resolution: Vessel provided current drug and alcohol program roster.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 January 2018 Resolved
Provid appropriate hull markings for international voyage.
Due 26 January 2018
Resolved 26 January 2018
Resolution: Loading marks properly painted on vessel.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 26 January 2018 Resolved
Provide satisfactory shaft alignment report for port and starboard propeller shafts.
Due 29 January 2018
Resolved 29 January 2018
Resolution: Shaft alignment corrected.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 18 April 2017 Resolved
the 8 person IBA needs to arranged so that it is secured, will float free from obstructions and attached to the vessel with a hydrostatic release
Action required: 705 - Other - as specified
Resolved 19 April 2017
Resolution: The IBA is arrange so that it is secured, can free float and attached to veesel with a painter that can be hydrostatically released.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 March 2017 Resolved
Draft and make available on board emergency instructions.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 9 March 2017
Resolution: Emergency insptructions provided

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.