Records from 2018 to 2026. Most recent: inspection, 27 July 2026.
Documentation record
Registered dimensions (L × B × D)347.6 ft × 83.1 ft × 24.0 ft
Registered tonnagegross 3,694 / net 3,070
ITC dimensions (L × B × D)347.6 ft × 83.1 ft × 24.0 ft
ITC tonnagegross 9,199 / net 3,323
BuilderVIGOR MARINE · SEATTLE, WA, UNITED STATES · built 2018
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9199 - Convention (Subpart B), Gross Ton
3694 - Regulatory (Subpart C or D), Gross Ton
3323 - Convention (Subpart B), Net Ton
3070 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 54
27 July 2026
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8448990
18 February 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312401
16 December 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8284443
14 November 2025
Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8268314
30 September 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8244269
28 September 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8261599
7 August 2025
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8198647
18 March 2025
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095856
15 November 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8037315
21 August 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7984962
28 June 2024
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7944538
21 June 2024
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7919768
3 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927314
5 March 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877988
21 June 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7721798
20 June 2023
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7721198
7 June 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7708135
17 March 2023
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7652433
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538481
9 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7529309
2 July 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7506804
18 June 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7483050
17 June 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7481221
31 May 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7464120
12 April 2022
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431869
5 January 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7389931
5 December 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7362708
16 November 2021
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7345453
16 July 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7254307
22 June 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7232519
13 May 2021
Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225572
16 February 2021
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7150540
10 November 2020
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7092694
19 September 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7061284
6 August 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026068
26 June 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6988036
4 June 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6968339
28 May 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6965515
12 May 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6953776
13 January 2020
MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6886060
11 December 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872249
22 August 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6792787
29 July 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6766787
16 July 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6788188
27 May 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6706888
13 May 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6683091
16 April 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6664005
24 March 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6649687
31 January 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6630184
20 December 2018
Administrative Inspection · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6600901
21 November 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6585010
18 October 2018
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6563966
17 September 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6547384
19 July 2018
MTSA Verification · Deficiency Check · Deadweight Survey · Construction Oversight · COI Inspection · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6484979
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2026
Resolved
The frame or support of each semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck.
The semi-portable extinguishers stowed in the fire hose cabinets on the main passenger deck are not in brackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 27 July 2026
Resolution: Portable exinguishers were placed into brackets.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2025
Resolved
All doors, except those that are kept normally closed, shall be of a type with are capable of release from the control station and from a position at the door. Several of the fire screen doors did not operate as intended. Door 028, 026 did not always close when the local control was pressed. Doors 018 and 007 would continue to open and close repeatedly. 46CFR72.05-25(b)(9) iii Action code = 16 C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 23 November 2025
Resolution: Doors operate as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2025
Resolved
No repairs or alterations affecting the safety of the vessel, with regard to the machinery, shall be made without knowledge of the [name withheld] of propulsion on the #1 main diesel engine. Provide root cause analysis and affect repairs. Schedule MI attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 19 October 2025
Resolution: Power pack replaced and sea trials completed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 June 2024
Resolved
Tests of the proper condition and operation of the rescue boat launching appliances at loads ranging from light load to 10 percent overload must be carried out whenever wire fall for a launching appliance is replaced or end-for-ended. Wire falls replaced for both rescue boats. Tests could not be performed due to davits unable to launch rescue boats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2024
Resolution: Satisfactory test operation of both rescue boat davits, to include weight tests.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2024
Resolved
Doors in stairway enclosures shall be of a type which are capable of release from the control station and from a position at the door. Sliding FSD 015 and 018 on car deck stairways inoperable at local releases.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2024
Resolution: Fire doors repaired and satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2024
Resolved
Doors in stairway enclosures shall be of the self-closing type capable of closing against a 3½ degree list. Sliding FSD 007 is not fully closing and jamming in the open position.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2024
Resolution: Fire doors repaired and satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2024
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire. Ventilation closures (ex:/ Supply Void #2, Supply Void #1, Natural Exhaust Steering Gear #2, etc.) throughout car decks unable to close either due to seized hinges and/or seized/missing fasteners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2024
Resolution: Ventilation closures repaired
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 June 2024
Resolved
Each fire hydrant must have at least one length of firehose. 4 fire hoses failed during operational pressure testing and replaced with spares.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2024
Resolution: Replaced with spares
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 June 2024
Resolved
AN INSPECTION, EITHER GENERAL OR PARTIAL DEPENDING UPON THE CIRCUMSTANCES, SHALL BE MADE WHENEVER ANY IMPORTANT REPAIRS OR ALTERATIONS ARE UNDERTAKEN.
VESSEL REPORTED LEAKING SHAFT SEAL ON #2 END. VESSEL TO RECTIFY AND MAKE REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2024
Resolved 28 June 2024
Resolution: Vessel went into drydock. Replaced stern tube seal. Operationally tested via 24 hour leak test. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 August 2022
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate or otherwise provides continued or restored propulsion capability in the event of a failure or malfunction of any single auxiliary component. The #2 SSDG is not operating as intended.
cite: 46 CFR 58.01-35
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 9 August 2022
Resolution: Submitted proof of repairs to the satisfaction of the [name withheld] complete.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2022
Resolved
Control air copper piping came out of tank fitting. Made temp repair using Parker 221FR SAE-J1942 hose. Make permanent repair for vital system.
46 CFR 56.60-25(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2022
Resolved 23 June 2022
Resolution: Installed metallic piping for permanent repair.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2021
Resolved
Each section of firehose must be a lined commercial firehose that conforms to UL 19. A hose that bears the label UL as a lined firehose is accepted as conforming to this requirement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 24 June 2021
Resolution: Fire hoses were replaced with UL approved hoses; operator sent in pictures of replacements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 May 2020
Resolved
Replace damaged fly wheel on #1 SSDG
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 17 June 2020
Resolution: New ring gear installed on SSDG, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2020
Resolved
46 CFR 199.190(g)/MSIB 09-20 / 705c (see description) - EACH INFLATABLE LIFESAVING APPLIANCE AND MARINE EVACUATION SYSTEM MUST BE SERVICED WITHIN 12 MONTHS OF EACH SUBSEQUENT SERVICING, EXCEPT WHEN SERVICING IS DELAYED, PROVIDED THE DELAY DOES NOT EXCEED 5 MONTHS. SERVICING DELAYS RELATED TO COVID-19 MEASURES HAVE IMPACTED VESSEL'S ABILITY TO HAVE LIFESAVING APPLIANCES AND MARINE EVACUATION SYSTEMS SERVICED WITHIN 12 MONTHS OF SUBSEQUENT SERVICING. SERVICING OF LIFESAVING APPLIANCES AND MARINE EVACUATION SYSTEMS MUST BE COMPLETED AS SOON AS POSSIBLE AND NOT LATER THAN 17 MONTHS FROM PRIOR SERVICING.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 August 2020
Resolution: Operator provided servicing certificates of MES and IBAs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 16 April 2019
Resolved
All vital systems are required to be operable from the emergency source of power (46 CFR 112.15-5(r)). The CPP and Auxiliary Cooling Pumps are vital systems and are not connected to the emergency bus. The emergency power system must be modified to meet 46 CFR 112.15-5(r) at the vessel's next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 July 2021
Resolved 29 July 2019
Resolution: Deficiency rescinded. Vital System loads are not required by 112.15-5(r), only vital system automation loads. CPP pumps are vital system loads.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018
Resolved
The vessel shall ensure that the necessary repairs or renewals are made every time an accident occurs or a defect is discovered which affects the safety of the vessel. The vessel has 3 pinhole leaks in the fuel tank seam on the vessel's #2 end starboard side with a small fuel leak. Provide repair proposal to USCG prior to effecting permanent repairs, continue to monitor condition, and report any additional issues or leaking to USCG.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 20 December 2018
Resolution: Pro-active employee mis-identified a fuel leak. Area in question was transition between day tank and overflow tank IWO centerline intercostal between frames 3 and 4 stbd side. Conducted ISE of entire compartment; found no evidence of fuel leak. No structu