MAURY USCG vessel records
← All vessels

FRONT RAUMA

FRONT RAUMA is a 2016 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in April 2026, along with 8 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 24 April 2026.

Built
2016
Last inspected
24 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9723100
1384600
Flag
LIBERIA
Maury page id
psix-1384600

Documentation record

Tonnage as PSIX records it17050 - Displacement, Metric Ton
157092 - Convention (Subpart B), Gross Ton
299986 - Dead Weight, Metric Ton
101100 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

24 April 2026 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8355227
13 September 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8001900
13 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7824001
8 February 2023 PSC B · COC-TVE Renew
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7635025
1 November 2021 PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7333372
3 November 2020 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7079247
20 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6956539
25 July 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6753619
15 September 2017 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6262535
8 September 2016 MARPOL Annex I Examination · MARPOL Annex VI Survey · COC-TVE Renew · ISPS III Exam · PII Safety Exam · ILO-147 Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5990133

Deficiency record · 8

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 2 May 2026 No resolution recorded
Each ballast water management system (BWMS) manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufacturer with the information listed in paragraph (b) of this section. Vessel ballast water treatment system did not have nameplate with Coast Guard approval requirements.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 May 2026 — due date passed with no resolution recorded
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 8 February 2023 Resolved
Every ship of 1OOGT and above shall carry a garbage management plan(GMP) which the crew shall follow. Crew did not follow GMP in that six 5 Gallon buckets with residue of Sodium Thiosulfate Pentahydrate UN#3077, environmentally hazardous substance, a Class 9 marine pollutant,found IVO dry food stores area being used to hold food scraps. Ship's GMP Section 8.9 requires chemical waste and environmental waste to be stored in the upper deck area. Further, disposal of such waste should only be made to shore reception facilities, not repurposed. MARPOL V/10.2, Rectify deficiencies prior to departure 17bc, Deficiency Rectified 10c.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 8 February 2023
Resolution: Removed buckets from dry storage.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 8 February 2023 Resolved
The IG System shall be capable of inerting and maintaining the atmosphere in cargo tanks with the required oxygen content. Crew unable to provide conformance report for IG span gas being used to calibrate IG system. Conformance report provided for bottle being used reflects expiration date of 40CT2022 - vessel discharged cargo in December 2022. Cargo operations are restricted until proof that IG system can be calibrated with certified span gas. 74SOLAS (14) 11-2/4.5.5.J.2. Rectify within 30 days, 50 bc.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 13 February 2023
Resolution: Recieved Flag report. Received 1 nitrogen bottle on 10th Feb 2023 at LB anchorage from our company’s vessel MT Maria and one new bottle on 13 Feb 2023. We have fixed the Nitrogen bottle in place with original arrangements and carried out calibration wi
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 February 2023 Resolved
15109 - The company and the ship shall comply with the requirements of the ISM code. Vessel failed to follow vessel's own cyber security SMS part 3.14, to use USB blockers. Blockers not found installed in 01 terminal. 74SOLAS(14)IX/5, ISM 10.1, Deficiency Rectified, 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 February 2023
Resolution: Installed missing USB blocker
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 February 2023 Resolved
15109- The company should establish procedures to ensure the ship is maintained [and] any non-conformity is reported, with its possible action, [and] appropriate corrective action is taken. Severely chaffed ballast tank vapor detection lines found throughout cargo deck area. One such finding found with duct tape and plastic wrap to protect exposed metallic piping. Defect, which was clearly identified due to temporary repair, was not reported to master and chief engineer for forwarding to technical department as required by vessel's SMS "04.01 .02 Defects Run-Once Jobs" Part 3.1.1. 74SOLAS (14)IX/5, ISM 10.2.2/3, Deficiency Rectified, 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 February 2023
Resolution: Temporary chafing material removed and defect was reported to master an chief engineer.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2021 Resolved
THE VENTING SYSTEM SHALL BE PROVIDED WITH DEVICES TO PREVENT THE PASSAGE OF FLAME INTO THE CARGO TANKS. FLAME SCREEN ON PV BREAKER WAS INSUFFICENTLY LASHED AT THE SEAM. 74SOLAS(20)II-2/4.5.3.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2021
Resolution: Crew reapired flame screen and class approved repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2021 Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. INTRINSICALLY SAFE TERMINATION WAS FOUND UNSEALED IN THE PURIFIER ROOM. 74SOLAS(20)II-1/45.5.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2021
Resolution: CLEARED ON THE SPOT
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2021 Resolved
OIL FUEL PIPES, WHICH, IF DAMAGED, WOULD ALLOW OIL THE ESCAPE FROM A STORAGE TANK HAVING A CAPACITY OF 500 L AND ABOVE SHALL BE FITTED WITH COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE CONCERNED. PNEUMATIC CONTROL LINE TO THE QUICK CLOSING VALVE ON THE LSMGO STORAGE THANK WAS DISCONNECTED. 74SOLAS(20)II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2021
Resolution: CORRECTED ON THE SPOT

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.