MAURY USCG vessel records
← All vessels

HAFNIA TURQUOISE

HAFNIA TURQUOISE is a 2016 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in December 2025, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 12 December 2025.

Built
2016
Last inspected
12 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9753674
1384653
Flag
MARSHALL ISLANDS
Maury page id
psix-1384653

Documentation record

Tonnage as PSIX records it13589 - Convention (Subpart B), Net Ton
49516 - Dead Weight, Ton
29492 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

12 December 2025 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8282675
16 October 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8250423
9 November 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029276
4 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029119
17 October 2023 COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7809884
17 April 2022 Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7432600
12 January 2021 Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7121350
31 March 2020 COC-CHEM & TVE Annual · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6933709
2 January 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6881606
20 December 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6877182
18 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644318
5 March 2019 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6634099
23 October 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6027928

Deficiency record · 2

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 October 2025 Resolved
Before the ship leaves port and at all times during the vessels voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed 02 food rations in port lifeboat damaged and exposed to air. ship has no additional spares onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2025
Resolved 21 October 2025
Resolution: Recieved delivery invoice for new food rations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 March 2019 Resolved
Ships carrying cargoes for which 15.12, 15.12.1 or 15.12.3 is listed in column "o" in the table of chapter 17 shall have on board, sufficient but not less than three complete sets of safety equipment, each permitting personnel to enter a gas filled compartment and perform work there for at least 20 minutes. Vessel is certified to carry products that require three full sets of safety equipment as listed on their COF. Vessel does not have the appropriate safety equipment. 74SOLAS(14) VII/10.1 Ref IBC Code 14.2.1 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 December 2019
Resolution: received images, invoices, and class report from ABS showing the three approved chemical suits required were obtained

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.