Records from 2016 to 2026. Most recent: inspection, 9 March 2026.
Inspection history · 16
9 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8320886
26 February 2025
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8085183
29 May 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7922592
26 February 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7870548
27 February 2023
Hull Examination · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7630844
23 February 2022
Internal Structural Exam · Administrative Inspection · Annual Inspection · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7400797
2 February 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7134453
17 March 2020
Drydock Extension · Annual Inspection · DAPI Audit · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6927938
14 January 2020
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6889129
8 January 2020
Simplified Stability Test
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6884995
27 February 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6634678
27 March 2018
COI Inspection · Hull Examination · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6368042
19 July 2017
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6213676
29 March 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6115035
3 May 2016
Administrative Inspection · Initial Certification · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5868284
15 March 2016
Construction Oversight · Simplified Stability Test
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5854768
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 March 2026
Resolved
All vessels must have navigation lights.
Starboard and aft light were extinguished.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2026
Resolution: Lights were repaired and burning brightly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2026
Resolved
Each ring life buoy on a vessel must:Be approved in accordance with § 160.050 in subchapter Q.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 26 March 2026
Resolution: New life ring was installed with appropriate Q-spec.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2026
Resolved
Fuel tank must meet standards of approval.
Tank top was deteriorated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 26 March 2026
Resolution: Tank was repalced with new tank.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2026
Resolved
The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
"FIRE BUCKET" Not stenciled on bucket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 26 March 2026
Resolution: All fire buckets now stenciled with "Fire Bucket".
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 26 February 2024
Resolved
47CFR80.903
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years.
FCC Safety Radiotelephony Certificate expired
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 29 May 2024
Resolution: COI amended to reflect operation within 1000 ft from shore. No longer requiring FCC Safety Radiotelephony Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024
Resolved
Each person operating a vessel to which this part applies shall present the certificate or lease or rental agreement required by § 173.21
Current registration was not on board or able to be presented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 6 March 2024
Resolution: Vessel rep sent in valid registration with operations stating "Commercial Passenger"
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024
Resolved
Certificate of number must contain the following information: (7) Primary Operation
VIS data shows vessel's primary use as pleasure, must verify updated to Commercial Passenger Carrying
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 6 March 2024
Resolution: Vessel rep sent in valid registration with operations stating "Commercial Passenger"
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2024
Resolved
Portable fire extinguishers installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 12 March 2024
Resolution: Vessel rep sent evidence into the charleston inspection inbox of acquring new bracket.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 February 2024
Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request.
No log was on board or available upon request.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 12 March 2024
Resolution: Vessel rep sent in record of drills.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 February 2022
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mountedat the primary operating station. Vessel was not equipped with a magnetic compass with light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 24 March 2022
Resolution: A new compass suitable for marine use was installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation.
Ensure fuel shutoff location is labeled accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Resolution: Fuel shutoff location labeled appropriately.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 March 2020
Resolved
Vessel's hull exam extended to 6/8/2020 due to Corona Virus outbreak.
Action required: 705 - Other - as specified
Due 8 June 2020
Resolved 8 June 2020
Resolution: Required inspections completed this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2019
Resolved
Mark F/O shutdown showing location and direction of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2019
Resolution: F/O shutoffs were marked correctly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 February 2019
Resolved
Provide replacement for missing lens cover for all around light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2019
Resolution: A new lens cover was placed in service.
Lifesaving › Lifebuoys › Stowage
Issued 3 May 2016
Resolved
Properly mount life ring to allow immediate access.
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 13 May 2016
Resolution: Vessel owner mounted lifering.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 May 2016
Resolved
Purchase and place in service UV resistant line for lifering.
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 13 May 2016
Resolution: Vessel owner placed new UV resistant line on lifering and water light.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2016
Resolved
Label Adult and Child life jacket stowage areas.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2016
Resolved 13 May 2016
Resolution: Adult and Child life jacket stowage areas were labled to indicate size and number.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016
Resolved
Replace expired medications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2016
Resolved 13 May 2016
Resolution: First aid kit was replaced with USCG approved kit.