MAURY USCG vessel records
← All vessels

TRISTAR NATASHA

TRISTAR NATASHA is a 2016 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in March 2026, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 6 March 2026.

Built
2016
Last inspected
6 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9721748
V7A6607
1385452
Flag
MARSHALL ISLANDS
Maury page id
psix-1385452

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it19801 - Dead Weight, Metric Ton
14034 - Convention (Subpart B), Gross Ton
26293 - Displacement, Metric Ton
6036 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

6 March 2026 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8316516
4 January 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8057463
17 December 2024 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8048367
19 November 2024 Deficiency Check · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8034681
5 February 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7860501
30 January 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7857867
26 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7320870
22 September 2021 PSC B · COC-CHEM Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7317787
16 January 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7125697
10 September 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7055325
6 May 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6949052
14 March 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6926822
13 September 2019 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6801788
18 June 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6718067
6 February 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6620805
7 August 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6503213
1 October 2017 NPV Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6278894
14 August 2017 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6233135
20 January 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6074056
12 July 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5938422

Deficiency record · 4

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 February 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESEENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED ALL HYRAULIC EMERGENCY SHUT-OFF VALVE SIGHT GLASSES BELOW HALF. ADDITIONALLY, PSCO OBSERVED HYDRAULIC LEAK WHEN TESTING MDG NUMBER 03. 74 SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 19 November 2024
Resolution: Verified deficiency was corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 5 February 2024 Resolved
THE COMPANY SHOULD IDENTIFY EQUIPMENT AND TECHNICAL SYSTEMS THE SUDDEN OPERATIONAL FAILURE OF WHICH MAY RESULT IN HAZARDOUS SITUATIONS. THE SAFETY MANAGEMENT SYSTEM SHOULD PROVIDE FOR SPECIFIC MEASURES AIMED AT PROMOTING THE RELIABILITY OF SUCH EQUIPMENT OR SYSTEMS. PSCO OBSERVED SMS INSTRUCTIONS THAT REQUIRED THE CREW TO CONDUCT A CHECK OF EMERGENCY SHUT-OFF VALVES EVERY 3 MONTHS IN ACCORDANCE WITH THE VESSEL'S PMS SYSTEM. [name withheld] AUDIT TO BE CONDUCTED ON THE VESSEL'S SMS PROCEDURES. 74 SOLAS(20) IX/3.1 ISM 10.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 19 November 2024
Resolution: Verified deficiency was corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 September 2020 Resolved
Emergency generating sets shall be capable of being readily started in their cold condition at a temperature of 0C. PSC Officer observed emergency generator starting control panel with auxiliary heating source that was not from manufacturer. (SOLAS 74 II-1/44.1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 January 2021
Resolution: SECTOR NEW ORLEANS PSC ARRIVALS BRANCH RECIEVED A CLASS REPORT SATISFYING THE REQUIREMENT
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 September 2019 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The fixed gas detection flow-fail alarm was inoperable. ship's safety procedure manual 7.6.2 states that ships where fixed gas sytems is used to monitor flammable atmospheres in non-cargo spaces. The crew shall ensure alarms are in good operational order. 74SOLAS (2014 CONS.) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 17 September 2019
Resolution: Vessel submitted images and corrective actions from Master and C/E attesting to the repairs

Ownership record