MAURY USCG vessel records
← All vessels

HSM 3702

HSM 3702 is a 2016 tank barge. The Coast Guard has recorded 14 inspections since 2016, most recently in February 2021, along with 7 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 3 February 2021.

Built
2016
Last inspected
3 February 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 February 2021
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1385690
Flag
UNITED STATES
Maury page id
psix-1385690

Documentation record

Tonnage as PSIX records it1619 - Simplified, Net Ton
1619 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

3 February 2021 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7135241
21 January 2021 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7126753
1 September 2020 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7060339
18 June 2020 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6980305
26 July 2019 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6763047
1 June 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6434252
8 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6408781
21 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6311533
13 September 2017 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6266043
19 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6213712
10 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6121345
30 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6079648
7 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6054613
30 June 2016 Internal Structural Exam · Administrative Inspection · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight · Cargo Tank Internal · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5986148

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 3 February 2021 Resolved
Port Cargo pump engine failed to secure when the e stop was pulled when tested on 3 FEB 2021. Barge was revisited again on 5 FEB 2021 and the engine was tested again from from the e stop and again failed to secure.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 13 February 2021
Resolved 13 February 2021
Resolution: Recieved Evidence of corrected emergency stop from [name withheld].
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 July 2019 Resolved
Each cargo tank of a tank barge must have an intrinsically safe high-level alarm and a tank over-fill alarm. The high-level and tank over-fill alarms were not able to be tested due to a faulty alarm. Repair alarm testing system to operable conditions to allow testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2019
Resolved 26 July 2019
Resolution: Alarms repaired and tested operable
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 July 2019 Resolved
Each vapor collection system must be tested annually or as part of the biennial and mid-period inspections. No records were onboard of a vapor tightness test being completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2019
Resolved 29 July 2019
Resolution: received documentation showing that the vapor tightness test was completed
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 1 June 2018 Resolved
06107: Prior to conducting discharge operations, show proper operation of the cargo pump engine to the attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2018
Resolution: Demonstrated proper operation of cargo pump engine and emergency shutdown.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 May 2018 Resolved
Due to Owner/Operator and Vessel Name change, the VRP on board is not currently correct. Require updated VRP to be placed onboard vessel to the satisfaction of the attending CG Marine Inspector. Vessel authorized continued full operations, route and service with current valid COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 7 June 2018
Resolution: VRP #20040 updated to add this barge. Copy of letter placed onboard barge.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 7 December 2016 Resolved
Revise the Electrical one line drawing to address the installation of a ground conductor between the barges,70amp rated double throw safety switch is protected by 70amp fuses, or that he switch is replaced with one rated at 100amp. An electrical interlock must be provided between the 100amp ovrboard power circuit and the TFU circuit breaker and install ground detection in the dist. system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 21 November 2017
Resolution: Verified electrical instalation satisfactory compared with one line diagram
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 30 June 2016 Resolved
No VALID Cargo Authority Attachment (CAA), vessel is restricted from conducting loading operations until a a vallid CAA has been received.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 1 September 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector, JWF

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.