MAURY USCG vessel records Sign in
← All vessels

HSM 3703

HSM 3703 is a 2016 tank barge. The Coast Guard has recorded 13 inspections since 2016, most recently in September 2024, along with 2 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 4 September 2024.

Built
2016
Last inspected
4 September 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1385691
Flag
UNITED STATES
—
Maury page id
psix-1385691

Inspections, by type

Years with a record 7 calendar years (2016–2024)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

4 September 2024 MTSA Verification · COI Inspection · Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7996169
3 June 2022 Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7469856
11 January 2021 COI Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7122630
19 September 2019 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6846118
27 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6650377
17 October 2018 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6564298
11 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6389375
30 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6314644
19 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6213724
10 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6121350
30 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6079655
7 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6054622
11 October 2016 Cargo Tank Internal · Internal Structural Exam · MTSA Verification · Administrative Inspection · Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6019919

Deficiency record · 2

14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 21 January 2021 Resolved
Flame screen missing on P/V valve
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2021
Resolution: Flame screen replaced
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 7 December 2016 Resolved
Revise the Electrical one line drawing to address the installation of a ground conductor between the barges,70amp rated double throw safety switch is protected by 70amp fuses, or that he switch is replaced with one rated at 100amp. An electrical interlock must be provided between the 100amp ovrboard power circuit and the TFU circuit breaker and install ground detection in the dist. system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 30 November 2017
Resolution: Verified installaton of ground conductor, 70 map rated safety switch and fuses.

Ownership record