Records from 2017 to 2026. Most recent: inspection, 25 March 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 11.0 ft × 3.4 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE SHIPBUILDING CORP · Salisbury, MD, UNITED STATES · built 2017
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
25 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8332036
17 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311531
4 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103567
23 April 2024
Annual Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7899722
12 April 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7720098
12 April 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7427295
14 May 2021
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7195435
28 April 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7184757
10 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6961978
24 April 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6669739
22 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6665735
30 May 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6428599
25 April 2017
Initial Certification · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6123893
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2026
Resolved
The design, construction, and stowage of portable fuel tanks and related fuel lines and accessories must meet the requirements of ABYC H-25.
Securing strap for port side portable gasoline fuel tank for outboard engine has deteriorated and broken, causing tank to no longer be strapped down.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 22 April 2026
Resolution: Received of portable fuel tank secured by a new strap.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2026
Resolved
One ring buoy must have a floating waterlight.
Battery on floating waterlight date stamped for 2018. Replace the battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 22 April 2026
Resolution: Received photo evidence of new floating water light installed on life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2026
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. The arrangement of the retroreflective material applied must be as specified by IMO Resolution A.658(16).
Ring buoy is missing the 4 retroreflective strips on each side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 22 April 2026
Resolution: Received photo evidence of new retro tape installed on life ring.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 April 2024
Resolved
A vessel not required to have a power driven fire pump must have atleast three 2.5 gallon fire buckets with attached lanyard placed so as to be easily available during and emergency. the words "FIRE BUCKET" must be stenciled in contrasting color. Marine inspector observed two fire buckets missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved photos of required quantity of fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 April 2024
Resolved
The emergency instructions placard should contain atleast the applicable portions of the "Emergency Instructions" and should be designed to address the particular equipment, arrangement, and operation of each individual vessel. Marine inspector observed the emergency instructions for the vessel to not align with the equipment available onboard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved documentation for updated emergency instructions applicable to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2024
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Marine inspector observed 05 child life jackets stowed in a location marked for adult life jackets and adult life jackets stowed in the designated child location.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 May 2024
Resolved 23 April 2024
Resolution: Crew members after inventory and inspection returned all life jackets to appropriate location.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew and other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; prevent electrical ignition of flammable vapors. Marine inspector observed frayed wires for the electric bilge pump located aft near the portable gasoline tanks and engines.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 May 2024
Resolved 23 April 2024
Resolution: Vessel crew repaired frayed wires to the satisfaction of USCG.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2022
Resolved
Twist-on type wire nuts were discovered being used on the main circuit breaker in a non-compliant manner. Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Provide photographic proof that existing twist-on type connectors have been removed and wiring has been restored to a condition in compliance with 46 CFR 183.340.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 21 April 2022
Resolution: [name withheld] sent in photographic evidence of rectified deficiency via email attachment
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 12 April 2022
Resolved
At an inspection for renewal of a Certificate of Inspection the vessel owner or operator must make the vessel available for all specific inspections and drills required by subpart H of 46 CFR 176. Due to weather, vessel could not get underway. Vessel to conduct MOB drill in presence of marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 21 April 2022
Resolution: [name withheld] submitted video evidence of a recent MOB drill to [name withheld] was reviwed and found to adequately prove crew proficency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 May 2021
Resolved
During ISE discovered multiple broken welds in the fwd peek void. 46CFR 176.600(c)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 1 June 2021
Resolution: Sent photos and a video of repairs.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 May 2021
Resolved
The voide access cover plates were not water tight. 46CFR 176.802(c)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 17 May 2021
Resolution: Vessel replaced o-rings on cover plates.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2021
Resolved
Vessel must undergo a drydock examination and internal structural examination at least once every two years. Subject vessel hull exams are due 30APR21. Vessel is restricted from operating after 30APR21 until hull exams are conducted to the satisfaction of the attending Marine Inspectors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2021
Resolved 14 May 2021
Resolution: Completed DDX and ISE