Records from 2016 to 2026. Most recent: inspection, 11 February 2026.
Documentation record
Registered dimensions (L × B × D)37.3 ft × 13.2 ft × 2.6 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
11 February 2026
COI Inspection · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317274
19 March 2025
Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8101510
7 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883245
27 March 2023
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7659502
23 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420363
19 April 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7175411
25 November 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7102110
8 October 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7074671
26 May 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6960911
28 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6697332
7 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6430407
18 May 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6419755
14 June 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6282692
22 March 2016
COI Inspection · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5932114
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2026
Resolved
Duct in the fuel tank space ventilation system is of combustible material. Combustible material is prohibited in these systems. Replace with noncombustible material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2026
Resolved 5 March 2026
Resolution: Combustible duct replaced with rigid aluminum.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 March 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond 3 miles, must have onboard a CAT 1 EPIRB installed. EPIRB installed onboard had expired battery date of 04/2022. Vessel is restricted to operations route of less than 3 miles until EPIRB is replaced.
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 17 April 2023
Resolution: RECEIVED PURCHASE REPORT FOR NEW CAT 1 EPIRB AND PICTURE OF NOAA REGISTRATION AND INSTALLATION, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2022
Resolved
No third fire bucket was present onboard.
46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 29 March 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 October 2020
Resolved
No annual or monthly servicing records of fire extinguishers. Portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see 175.600). Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. 46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2020
Resolved 15 October 2020
Resolution: Fire extinguisher serviced by recognized company. Operator to begin recording monthly checks/servicing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 May 2019
Resolved
Fixed fire extinguisher to be mounted vertically per instructions on the bottle. Extinguisher also required to be CO2 not dry chem. 46CFR181.410
Action required: 705 - Other - as specified
Due 6 June 2019
Resolved 13 June 2019
Resolution: Properly installed 5lb CO2 in space
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2019
Resolved
Hydrostatic release for EPIRB is expired. Replace. 46CFR185.740
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 13 June 2019
Resolution: Installed HRU due to expire 6/2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019
Resolved
Battery in Ring Buoy Light is expired. Replace battery with approved screw post type. 46CFR185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 13 June 2019
Resolution: Replaced battery
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 May 2019
Resolved
Flame screen not installed on heater's disel tank. Install flame screen. 46CFR182.450(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 14 June 2019
Resolution: RCVD pic of installed flame screen
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019
Resolved
Missing bilge pump. Install pump IAW approved plan AMI Dwg. No. 16-1287-04-07, Rev. A, “Systems Piping Bilge,” 1 sheet, dated April 15, 2016. 46CFR182.520
Action required: 705 - Other - as specified
Due 6 June 2019
Resolved 4 June 2019
Resolution: See Activity
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2018
Resolved
05199 - FCC SAFETY RADIOTELEPHONY CERTIFICATE WAS NOT ONBOARD THE VESSEL, SHOWING PROOF OF RADIO INSTALLATION INSPECTION. EVERY VESSEL MUST HAVE A DETAILED INSPECTION OF THE RADIO INSTALLATION ONCE EVERY FIVE YEARS. - 50C - 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 22 June 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 7 June 2018
Resolved
05199 - VESSEL CALL SIGN NOT READILY POSTED NEAR VHF STATION. A DURABLE PLACARD MUST BE POSTED NEXT TO ALL RADIOTELEPHONE INSTALLATIONS WITH THE EMERGENCY BROADCAST INSTRUCTIONS AND INFORMATION, SPECIFIC TO THE INDIVIDUAL VESSEL. - 50C - 46 CFR 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 22 June 2018
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 7 June 2018
Resolved
11118 - LIFE JACKETS MARKED WITH VESSEL FORMER NAME, NOT CURRENT NAME. EACH LIFE JACKET MUST BE MARKED WITH THE VESSEL'S NAME. 50C - 46 CFR 185.604(B)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 28 June 2018
Lifesaving › Visual Distress Signals (General) › Marking
Issued 5 August 2016
Resolved
Visual Distress watertight container not marked IAW 46CFR185.614 with the words "DISTRESS SIGNALS" .5 inches high.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2016
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard. The lanyard attached to the floating waterlight does not meet requirments of 46CFR180.175.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 August 2016
Resolved
Portable lights required by 46CFR183.430 did not have batteries installed.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019