J1

J1 is a 2016 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in February 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 11 February 2026.

Built
2016
Last inspected
11 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI8851
1386417
Flag
UNITED STATES
Maury page id
psix-1386417

Documentation record

Registered dimensions (L × B × D)37.3 ft × 13.2 ft × 2.6 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

11 February 2026 COI Inspection · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317274
19 March 2025 Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8101510
7 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883245
27 March 2023 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7659502
23 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420363
19 April 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7175411
25 November 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7102110
8 October 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7074671
26 May 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6960911
28 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6697332
7 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6430407
18 May 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6419755
14 June 2017 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6282692
22 March 2016 COI Inspection · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5932114

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2026 Resolved
Duct in the fuel tank space ventilation system is of combustible material. Combustible material is prohibited in these systems. Replace with noncombustible material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2026
Resolved 5 March 2026
Resolution: Combustible duct replaced with rigid aluminum.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 March 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond 3 miles, must have onboard a CAT 1 EPIRB installed. EPIRB installed onboard had expired battery date of 04/2022. Vessel is restricted to operations route of less than 3 miles until EPIRB is replaced.
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 17 April 2023
Resolution: RECEIVED PURCHASE REPORT FOR NEW CAT 1 EPIRB AND PICTURE OF NOAA REGISTRATION AND INSTALLATION, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2022 Resolved
No third fire bucket was present onboard. 46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 29 March 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 October 2020 Resolved
No annual or monthly servicing records of fire extinguishers. Portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see 175.600). Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. 46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2020
Resolved 15 October 2020
Resolution: Fire extinguisher serviced by recognized company. Operator to begin recording monthly checks/servicing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 May 2019 Resolved
Fixed fire extinguisher to be mounted vertically per instructions on the bottle. Extinguisher also required to be CO2 not dry chem. 46CFR181.410
Action required: 705 - Other - as specified
Due 6 June 2019
Resolved 13 June 2019
Resolution: Properly installed 5lb CO2 in space
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2019 Resolved
Hydrostatic release for EPIRB is expired. Replace. 46CFR185.740
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 13 June 2019
Resolution: Installed HRU due to expire 6/2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019 Resolved
Battery in Ring Buoy Light is expired. Replace battery with approved screw post type. 46CFR185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 13 June 2019
Resolution: Replaced battery
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 May 2019 Resolved
Flame screen not installed on heater's disel tank. Install flame screen. 46CFR182.450(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 14 June 2019
Resolution: RCVD pic of installed flame screen
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019 Resolved
Missing bilge pump. Install pump IAW approved plan AMI Dwg. No. 16-1287-04-07, Rev. A, “Systems Piping Bilge,” 1 sheet, dated April 15, 2016. 46CFR182.520
Action required: 705 - Other - as specified
Due 6 June 2019
Resolved 4 June 2019
Resolution: See Activity
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2018 Resolved
05199 - FCC SAFETY RADIOTELEPHONY CERTIFICATE WAS NOT ONBOARD THE VESSEL, SHOWING PROOF OF RADIO INSTALLATION INSPECTION. EVERY VESSEL MUST HAVE A DETAILED INSPECTION OF THE RADIO INSTALLATION ONCE EVERY FIVE YEARS. - 50C - 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 22 June 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 7 June 2018 Resolved
05199 - VESSEL CALL SIGN NOT READILY POSTED NEAR VHF STATION. A DURABLE PLACARD MUST BE POSTED NEXT TO ALL RADIOTELEPHONE INSTALLATIONS WITH THE EMERGENCY BROADCAST INSTRUCTIONS AND INFORMATION, SPECIFIC TO THE INDIVIDUAL VESSEL. - 50C - 46 CFR 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 22 June 2018
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 7 June 2018 Resolved
11118 - LIFE JACKETS MARKED WITH VESSEL FORMER NAME, NOT CURRENT NAME. EACH LIFE JACKET MUST BE MARKED WITH THE VESSEL'S NAME. 50C - 46 CFR 185.604(B)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 28 June 2018
Lifesaving › Visual Distress Signals (General) › Marking
Issued 5 August 2016 Resolved
Visual Distress watertight container not marked IAW 46CFR185.614 with the words "DISTRESS SIGNALS" .5 inches high.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2016 Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard. The lanyard attached to the floating waterlight does not meet requirments of 46CFR180.175.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 August 2016 Resolved
Portable lights required by 46CFR183.430 did not have batteries installed.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 30 May 2019