Records from 2016 to 2026. Most recent: inspection, 11 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)174.4 ft × 31.8 ft × 14.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)174.4 ft × 31.8 ft × 14.0 ft
ITC tonnagegross 495 / net 148
BuilderBREAUX BROTHERS ENT INC · LOREAUVILLE, LA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it495 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
11 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8309334
16 December 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8047826
19 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037256
7 December 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7833685
6 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7632437
19 January 2023
Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7623671
2 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7466843
18 January 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7381867
5 February 2021
Drydock Exam · Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7136259
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110427
21 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6941745
28 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6616287
16 January 2019
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6611191
16 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6392755
19 January 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6073508
18 May 2016
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6086177
31 January 2016
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6086184
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 December 2023
Resolved
Emergency Egress Training for all members of the crew to be conducted at least monthly. Last recorded Egress Drill was conducted in October 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 12 December 2023
Resolution: Egress drill was conducted and proof was sent over from Vessel Rep [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2023
Resolved
Vessels with standby endorsement must have a fire monitor onboard. Vessel had no fire monitor onboard due to being in the process of removing standby endorsement/equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 8 December 2023
Resolution: Vessel's standby endorsement was removed from the COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
Electrical Equipment exposed to corrosive enviroments must be of suitable construction and corrosion resistant. Wire on outboard water heater was worn and corroded.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Corroded wire was replaced with good wire
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2023
Resolved
A 40-B portable extinguisher may substitute a fixed gas extinguishing system for a paint locker. Extinguisher hose was broken and corroded beyond operational use.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Bad hose was replace with a brand new servicable one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2022
Resolved
46 CFR 182.430: Exhaust piping must not leak gas from piping or any connection; weld cracked on port forward exhaust pipe; must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 31 January 2022
Resolution: Received confirmation from the vessel rep that the lagging on the port aft exhaust pipe was pulled to detemine if there were any leaks associated with the weld in question. There were no leaks, and the weld was cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 January 2022
Resolved
46 CFR 181.300: Fire pump must be fitted with a working pressure gauge; pressure gauge in operable, must be repaired.
Action required: 10 - Deficiency Rectified
Due 18 February 2022
Resolved 19 January 2022
Resolution: Gauge replaced in presence of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 January 2022
Resolved
46 CFR 171.111: Each opening in a watertight bulkhead must have a means to close and make it watertight; Gaskets on watertight doors did not wrap around entirety of door. Gaskets to be replaced and doors readjusted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 30 January 2022
Resolution: Vessel replaced all watertight door gaskets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 February 2021
Resolved
Watertight doors shall be watertight. Five Class-1 Watertight Doors need to be adjusted or gaskets replaced. To be cleared by attending USCG Marine Inspector.
46 CFR 175.400/ 46 CFR 170.270(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: New gasket material installed and doors adjusted.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 23 January 2017
Resolved
Vessel shall conduct dynamic postiioning trials with an ABS representative present. Trials shall be in accordance with ABS approved procedures. ABS to provide report to Coast Guard MSD Lafayette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: ABS conducted DP trials.