MAURY USCG vessel records Sign in
← All vessels

ISLAND EXPLORER 5

ISLAND EXPLORER 5 is a 2017 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in May 2025, along with 4 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 5 May 2025.

Built
2017
Last inspected
5 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4789
1387484
Flag
UNITED STATES
369264000
Maury page id
psix-1387484

Inspections, by type

Years with a record 9 calendar years (2016–2025)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.8 ft × 29.0 ft × 8.9 ft
Registered tonnagegross 98 / net 75
ITC dimensions (L × B × D)90.8 ft × 29.0 ft × 8.9 ft
ITC tonnagegross 215 / net 72
BuilderMAVRIK MARINE INC · LA CONNER, WA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portANACORTES, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Net Ton
215 - Convention (Subpart B), Gross Ton
72 - Convention (Subpart B), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4789MMSI 369264000 · active · compulsorily equipped · granted 6 April 2017, expires 6 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

5 May 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8129274
11 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8092389
9 May 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7913734
15 May 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690071
28 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7643601
3 October 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7570996
26 September 2022 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7568129
28 March 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7419890
16 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416441
7 June 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7218583
17 February 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7144451
25 November 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7102122
20 April 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6940162
10 December 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6871584
24 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6720011
28 January 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616431
16 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6415442
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360433
17 May 2016 Plan Review "T" Boat · Deadweight Survey · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108422

Deficiency record · 4

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 March 2025 Resolved
PSS shaft seal rubber bellows is delaminating at the manufacturer installed reducer where attached to the shaft log both port and starboard. Repair IAW OEM standards or replace with new bellows.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2025
Resolved 17 March 2025
Resolution: Seals and bellows replaced on both shafts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2022 Resolved
Vessel must submit evidence of developed safe handling procedures for the operation and storage of potentially hazardous items such as rechargeable batteries. 87 Federal Register 73160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2022
Resolved 18 April 2022
Resolution: Submitted plan
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2022 Resolved
Vessel must submit evidence of marine firefighting training programs to improve crewmember training and proficiency, including egress training for each member of the crew. 87 Federal Register 73160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2022
Resolved 18 April 2022
Resolution: Submitted plan
Stability › Unintentional Flooding › General
Issued 25 May 2017 Resolved
Vessel is limited to a Lakes, Bays, and Sound route until a 6" sill is install or an approved temporary sill is provided, IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Resolved 8 February 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.