← All vessels
THEKLA SCHULTE
THEKLA SCHULTE is a 2014 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in May 2026, along with 4 deficiencies.
Records from 2019 to 2026. Most recent: inspection, 9 May 2026.
- Built
- 2014
- Last inspected
- 9 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9551777 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6252
1387549
Flag
SINGAPORE
—
Maury page id
psix-1387549
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2019–2026)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it12743 - Convention (Subpart B), Gross Ton
3823 - Convention (Subpart B), Net Ton
14999 - Dead Weight, Metric Ton
22100 - Displacement, Metric Ton
3823 - Convention (Subpart B), Net Ton
14999 - Dead Weight, Metric Ton
22100 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
9 May 2026
Administrative Inspection · COC-GAS Annual
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8369683
26 June 2025
PSC B · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8162550
14 February 2024
PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7865166
22 August 2022
COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7538391
14 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7350488
17 September 2021
Deficiency Check · COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7306364
13 August 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6783596
9 August 2019
Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6766052
9 August 2019
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6794987
Deficiency record · 4
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2022
Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the administration and a record of this action, including the valves of set pressure, should be retained aboard the ship.
PSCO ovserved cargo tanks relief valve 2PS and 2SB were serviced and resealed with new wire on 24 DEC 2021, however, class acceptance document is dated 03 JUL2019.
1993 IGC 8.2.5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 September 2021
Resolved
17SOALS14/VII/13.1
93IGC/10.2.4.1
Ligthting fittings should have pressorized enclosures or should be of flameproof type.
PSCO found a cracked lighting fixture cover in the cargo compressor room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2021
Resolved
74SOLAS14 I/11
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations.
Temperature sensor insulation/protective tube has failed at the following locations: Booster pump fitting to monitoring box on deck, port manifold vapor line, port and starboard vapor temperture monitoring boxes on deck.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 August 2019
Resolved
In every installation, the position of fixed sampling heads should be determined with due regard to the density of the vapors of the products intended to be carried and the dilution from compartment purging or ventilation.
Deck store space, a space located within the compressor room and considered a gas dangerous zone as defined by the code, is not fitted with gas sampling points in the upper part of the space despite being authorized to carry anhydrous ammonia, a cargo with a vapor density of approximately .597.
93IGC 13.6.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.