← All vessels
DELTAGAS
DELTAGAS is a 2013 tank ship. The Coast Guard has recorded 6 inspections since 2016, most recently in February 2026, along with 5 deficiencies.
Records from 2016 to 2026. Most recent: inspection, 9 February 2026.
- Built
- 2013
- Last inspected
- 9 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9540003 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2IF3
1387551
Flag
MALTA
—
Maury page id
psix-1387551
Inspections, by type
Years with a record
5 calendar years (2016–2026)
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3846 - Convention (Subpart B), Net Ton
14999 - Dead Weight, Metric Ton
21959 - Displacement, Metric Ton
12819 - Convention (Subpart B), Gross Ton
14999 - Dead Weight, Metric Ton
21959 - Displacement, Metric Ton
12819 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
9 February 2026
COC-GAS Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8304772
7 February 2024
PSC B · Administrative Inspection · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7862059
30 April 2021
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7187961
20 April 2021
COC-GAS Renew · Ballast Water Examination · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7179272
6 July 2018
ISPS II Exam · Administrative Inspection · Deficiency Check · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6465628
27 July 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5954784
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 July 2018
Resolved
Remote starting of pumps supplying the water spray system should be arranged in suitable locations outside the cargo area and readily accessible and operable in the vent of fire in the areas protected.
The deck water spray pump upon remote actuation is found inoperable.
Provide class report attesting to the satisfactory repair and oepration of the deck water spray system. Provide class report attesting to the root cause of the inoperable sprinkler pump.
74 SOLAS 14 VII/13.1 REF IGC 93/11.3.6
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 July 2016
Resolved
On ships carrying flammable or toxic products, a water spray system for cooling, fire prevention and crew protection should cover boundaries of superstructures, cargo compressor rooms and exposed tank domes. PSCO identified 16 nozzels in way of #2 tank dome and FWD boundary of compressor room that were either blocked or providing insufficient spray.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 July 2016
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. The door to fire equipment and deck store room #234 (FWD of compressor room) is listed on the fire control plan as an "A-class self-closing fire door". They will not close properly on its own.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 July 2016
Resolved
In zones on open decks over the cargo area electrical equipment shall be certified safe type equipment or approved for operation in a flammable atmosphere. PSCO found the lens cover for an Ex d approved light cracked. The light is located on main deck, STBD side at fwd of superstructure.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 27 July 2016
Resolved
Test procedures for fixed gas detection equipment should be approved by the administration. PSCO found the hydrocarbon sensor in the gas detection cabinet to be different than the sensor listed in the cargo operations manual. The new sensor is of a differnt make and model.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National