Records from 1987 to 2018. Most recent: inspection, 11 March 2018.
Documentation record
Registered dimensions (L × B × D)34.8 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 21 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHIP SERVICE & CHARTERS · VANCOUVER, WA, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWINCHESTER BAY, OR
Trade endorsementsFishery
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
11 March 2018
Type not recorded
No type recorded · USCGC ADELIE (WPB 87333) · USCG Northwest District (CGD-NW) · Activity 6401228
4 May 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2070767
5 February 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1103891
25 April 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1083315
30 March 1995
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428459
29 April 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1358385
24 May 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 828048
30 April 1993
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382560
12 January 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1133816
7 June 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1268060
18 May 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1261459
28 February 1992
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1315003
9 July 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1246610
1 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238824
19 March 1991
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1235185
30 January 1990
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 977812
15 March 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1209664
13 February 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1038880
10 March 1988
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1283464
4 June 1987
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1027130
26 February 1987
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002894
Construction/Loadline
Issued 25 April 1996
Resolved
INSTALL VALVE OR PLUG DRAIN HOLE A TRANSOM FOR STERN VOID SPACE. DRAIN HOLEIS WITH-IN 6 INCHES OF THE WATERLINE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Navigation
Issued 25 April 1996
Resolved
REMOUNT MAST FOR MAST HEAD LIGHT DUE TO MOUNTING BRACKET BEING LOOSE AT THEBASE. REATTACH WEAK LINK WHEN REPAIRS COMPLETE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Construction/Loadline
Issued 30 April 1993
Resolved
CONDUCT SATISFACTORY TEST OF BILGE SYSTEM.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Engineering
Issued 30 April 1993
Resolved
CONDUCT SATISFACTORY TEST OF MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 28 February 1992
Resolved
INSTALL CHECK VALVE AT HULL ON ENGINE OVERBOARD, PORT SIDE, AT WATERLINE, UNDER HEAD.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Engineering
Issued 28 February 1992
Resolved
VERIFY SATISFACTORY OPERATION OF PROPULSION ENGINE AND BILGE PUMPS WITH LETTER.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Engineering
Issued 28 February 1992
Resolved
MODIFY EMERGENCY FUEL SHUT-OFFS WITH CABLE-PULLS OR REACH RODS SUCH THAT THEY ARE EASILY ACCESSIBLE FROM THE DECK AND ISOLATED FROM THE SPACE.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Documentation
Issued 19 March 1991
Resolved
SUBMIT OPERATIONAL TEST FORM.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991
Resolved
PLACE SUITABLE STRAINER ON BILGE LINE IN FORWARD COMPT.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 13 February 1989
Resolved
PROVIDE TRAYS OF FRP OR OTHER SUITABLE MATERIAL FOR BATTERIES, AND MOVE TO LOCATION W/MIN 10" HEADROOM 183.05-20(B)&(D).
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Fire Fighting
Issued 13 February 1989
Resolved
PROVIDE MEANS FOR CLOSING E/R VENTS TO ISOLATE THE SPACE IN THE EVENT OF FIRE/DISCH. OF FIXED SYSTEM.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Navigation
Issued 26 February 1987
Resolved
PRIOR TO OPERATING THE VESSEL DURING HOURS OF DARKNESS OR RESTRICTED VISIBILITY, THE STERN AND ANCHOR LIGHTS MUST BE MADE OPERABLE.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987
Lifesaving
Issued 26 February 1987
Resolved
VESSEL IS LIMITED TO CARRIAGE OF SIXTEEN TOTAL PERSONS UNTIL THE SIX REJECTED PERSONAL FLOATATION DEVICES (LIFE JACKETS) ARE REPAIRED OR REPLACED.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987
Lifesaving
Issued 26 February 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, THE BUOYANT APPARATUS MUST HAVE THE LIFE LINES REPLACED.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987