Inspection history · 48
7 April 2026
Vessel Attendance · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8344992
16 September 2025
Vessel Attendance · Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8244537
9 June 2025
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8157529
9 June 2025
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8179822
3 April 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8108499
31 July 2024
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7977545
20 June 2024
In-Service Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7939274
10 January 2024
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7858205
3 January 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7844940
11 September 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7557409
11 September 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558215
4 August 2022
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7525045
5 July 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7497870
29 August 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6808990
8 August 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6781541
28 June 2018
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6452569
5 June 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6435204
30 March 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6383674
26 April 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5863411
22 April 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867661
19 November 2013
MARPOL · MTSA Verification · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4756326
4 December 2012
Administration
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4496757
21 July 2011
Deficiency Check · Administration · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4089625
1 June 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4030101
28 May 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4029027
20 March 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3763932
25 April 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3464288
25 March 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3171105
11 June 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2958099
11 April 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2907192
23 May 2006
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2657026
12 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2647614
7 October 2005
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2509846
12 July 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2423888
9 March 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2397672
8 August 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2169974
18 February 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2008971
9 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1961249
20 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1797425
27 January 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1736230
30 April 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7740
30 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40262
6 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 651302
5 January 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766540
10 December 1998
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 194925
23 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762493
5 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194956
5 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194966
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Have suitable propulsion controls to provide the operator full control at each operating station. Port side main engine unable to shutdown from main op station. Repair prior to commercial operations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Witnessed port main engine shutdown from bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2026
Resolved
Alarms must: be visible and audible at each operating station. Both main engine alarm panels show false alarms for oil temperature and pressure at main operating station. Repair prior to commercial operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Alarm panel repaired satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2026
Resolved
A record of the type, size, and servicing of each towline used to make the vessel fast to her tow must be available to the Coast Guard for review. Provide documentation to attending Marine Inspector for newly installed towline within one week.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 April 2026
Resolution: Certs provided and uploaded.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 April 2026
Resolved
Fire extinguishing equipment and detection: Receipts and other records generated by these inspections and tests must be retained and made available upon request. Provide fire servicing records for all equipment to attending Marine Inspector within one week.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 April 2026
Resolution: Fire servicing completed. uploading cert
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 April 2026
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Machinery space electrical panel open at rear of panel, generator batteries exposed to dripping water. Replace electrical panel covering to minimize shock hazard and protect battery within one week.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 April 2026
Resolution: Panel cover replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 April 2026
Resolved
Electrical connections must be suitable installed to prevent them from coming loose through vibration of accidental contact. Battery connections secured with wingnuts. Provide suitable battery connection means within one week.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 April 2026
Resolution: Battery suitably connected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 October 2025
Resolved
The dry dock examination must be conducted while the vessel is hauled out of the water or placed in a dry dock or slipway. Examine the exterior of the hull, including bottom, sides, head-log, and stern, and examine all appendages for damage, fractures, wastage, pitting, or improper repairs. Pot rudder bottom was wasted and stbd rudder bottom was holed and had a compromised weld on the port side. Make proper repairs on marked areas to the satisfaction of the attending marine inspector or classification society.
46 CFR 137.330(a)(1)
Action required: 705 - Other - as specified
Resolved 13 November 2025
Resolution: Repairs made to the satisfaction of the attending inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 September 2025
Resolved
(b) A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Submit repair proposal to address identified substantial and excessive wastage.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 7 January 2026
Resolved 12 March 2026
Resolution: Vessel submitted repair proposal and completed identified worklist items.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. While in transit to Long Beach from Honolulu, the vessel reported a failure of their main bus tie breaker. This was caused by a loose wire connection from the breaker to the forward bus bar, which created an arc. The breaker has been electrically isolated and all propulsion and electrical systems on board remain fully functional. Vessel shall effect permanent repairs to the electrical system to the satisfaction of an attending marine inspector prior to departing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2025
Resolved 18 June 2025
Resolution: All damaged electrical equipment replaced in kind and verified fully operational. See uploaded documents/photos for additional info.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2025
Resolved
Each towing vessel operating on oceans, coastwise, limited coastwise, or beyond 3 nautical miles from shore upon the Great Lakes must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon (EPIRB) that meets the requirements of 47 CFR part 80. Vessel does not have an operational EPRIB onboard as required by regulation. Vessel is restricted to a Lakes, Bays, and Sounds route until a registered, serviced, EPIRB is onboard the vessel. Vessel must demonstrate EPRIB is registered and operation to the satisfaction of an attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Resolved 18 June 2025
Resolution: Vessel has replaced their EPIRB entirely due to long lead time for a new battery from manufacturer. Reviewed copy of registration valid through July 2027 and verified proper installation.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 June 2024
Resolved
46 CFR 144.145: Vessel must also provide procedures for verification of compliance with design standard: (g)(6) As referred to in this section, the term plan may include, but is not limited to drawings, documents, or diagrams of the following: (6) Machinery installation, including, but not limited to: (iv) Fuel transfer and service system, including tanks. Day tank fuel supply line in engine room overhead with non-metallic hose. Show proof that installed non-metallic hose is in accordance with approved fuel piping system.
Action required: 705 - Other - as specified
Due 27 July 2024
Resolved 31 July 2024
Resolution: Found fuel manifold and transfer system as designed. The previously portable fuel hose connecting to the ballast system was removed and a permanent section of hose was connected to the fuel manifold and transfer system. Vessel has transfer procedures howe
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 June 2024
Resolved
Vessel was not in compliance with Stability Letter dated October 31, 2002 issued by ABS on behalf of the Coast Guard. Specifically, under Operating Restrictions, paragraph No. 5, Tanks. Vessel’s records and crew statements confirm that fuel was loaded into ballast tank No. 1 forward and ballast tank No. 2 aft center on 17MAY2024 prior to its departure from Honolulu, HI to Palau. As a result, the operating restrictions stipulated in the vessel’s stability letter were not followed, which prohibited the vessel from maintaining a proper trim. The vessel must demonstrate compliance with its stability letter to the satisfaction of the attending USCG marine inspector and ABS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Vsl rep. reviewed and discussed with crew operational restrictions per approved stability letter documented it on company's form for drills. Copy submitted to USCG and uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 June 2024
Resolved
46 CFR 143.205(a): Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. USCG discovered unapproved alterations/modifications to the No. 1 forward center ballast and No. 2 aft center ballast pipe manifolds located in the engine room. Ballast piping system must be restored IAW original approved plans. Final repairs and operational test must be attested by the attending USCG Marine Inspector. Submit repair plan to USCG for review.
Action required: 30 - Ship detained
Resolved 27 June 2024
Resolution: Ballast manifold located in engine room was restored to its original configuration to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 June 2024
Resolved
46 CFR 140.205 (a): A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property and the environment. Ballast tanks No. 1 forward center and No. 2 aft center must be free of all fuel and cleaned prior to carrying ballast. Prior to returning to service, ballast tanks must be certified gas free by a marine chemist for USCG’s inspection. Vessel must also provide procedures for verification of compliance with design standards in accordance with 46 CFR 144.145 respectively: (g)(6) As referred to in this section, the term plan may include, but is not limited to drawings, documents, or diagrams of the following: (6) Machinery installation, including, but not limited to: (iv) Fuel transfer and service system, including tanks; (v) Piping systems including: bilge, ballast, hydraulic, combustible and flammable liquids, vents, and overflows.
Action required: 30 - Ship detained
Resolved 27 June 2024
Resolution: No. 1 forward and No. 2 aft center ballast tanks were inspected free of fuel. Line drawing of ballast lines/valves submitted by vsl rep.and uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 June 2024
Resolved
46 CFR 140.205(a): A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property and the environment. Remove all oily waste in bilges and properly dispose of ashore in accordance with local ordinances.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: MI observed no oily waste in bilge at time of attendance. Per vsl rep. approx. 183 gallons of oily waste transferred into vessel's slop tank and will be disposed of in Hawaii NLT 27JUL2024.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2024
Resolved
46 CFR 143.205(c)(1 and 2): Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation and be suitable for route and service. Repair leak to port side shaft to the satisfaction of the attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Observed by attending MI to be leak free. Vessel crew re-applied packing that stopped ingress of water.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 20 June 2024
Resolved
46 CFR 15.401 (b) and (c): A person may not employ or engage an individual in a position to hold an MMC unless that individual maintains a current medical certificate. Company employed an individual as the OS with an expired medical certificate during the voyage from 18MAY2024 to 20JUN2024. Crewmember’s medical certification for national endorsement expired on 20SEP2023 and for STCW expired on 20SEP2020. Prior to departure, all persons employed or engaged in a position to hold an MMC must have proof of a current medical certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Verified incoming crew has current/valid Medical Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 January 2024
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Found small hole in discharge side of fire pump piping.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 12 March 2024
Resolution: Fire pump and associated piping was replaced and tested sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 January 2024
Resolved
Station documents must be readily available to the licensed operator(s) on duty during the hours of service of the station and to the authorized Commission employees upon request. The vessel's call sign is not updated on the FCC Documents.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 12 March 2024
Resolution: New FCC certificates were issued to vessel with updated Call Sign.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Steering RAM seal failed. Replace seal to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 143.205(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2022
Resolution: Ram seals and hoses for steering ram was replaced. Steeering ram test conducted and satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 August 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. The smoke detector in the galley was removed.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 August 2022
Resolved 4 August 2022
Resolution: Crew re-installed detector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2022
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibrations or accidental contact. Port searchlight junction box mounting bracket is missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 18 August 2022
Resolution: Bracket installed and mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2022
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Power breaker junction box for house A/C unit is severely rusted and needs remounting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 18 August 2022
Resolution: Junction box replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 4 August 2022
Resolved
Each mattress must comply with either: The Consumer Product Safety Commission Standard for Mattress Flammability and not contain polyurethane foam; or IMO Resolution A.688(17)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 18 August 2022
Resolution: Mattresses replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 4 August 2022
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure must be equipped with an indicating pressure gauge and with one or more spring loaded relief valves. Port side relief valve for air compressor is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 24 August 2022
Resolution: Relief valve replaced and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 August 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port generator gauges for water temperature and RPM needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 18 August 2022
Resolution: Gauges re-installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Remove dead end cable/antenna from behind bridge house.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 August 2022
Resolved 18 August 2022
Resolution: Cable removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 August 2022
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating to the size of the crew and operating conditions. Vessel's first-aid kit has expired items throughout the kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 24 August 2022
Resolution: First-aid kit has been updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 July 2022
Resolved
(a) A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202.
(b) Each towing vessel certificated under the provisions of this subchapter must be in full compliance with the terms of the COI.
Vessel is not able to meet the Sub M phase-in requirements of 46 CFR 1360.202 and is restricted from movement until vessel can complete a Certification of Inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 July 2023
Resolved 12 August 2022
Resolution: Vessel conmpleted Certificate of Inspection.