Records from 2017 to 2026. Most recent: operational control imposed, 22 April 2026.
Inspection history · 62
22 April 2026
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8353814
14 April 2026
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8349477
1 March 2026
Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8318086
16 January 2026
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8298503
11 February 2025
COC-CHEM & TVE Annual
Type not classified · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8078146
25 September 2024
In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8009333
23 September 2024
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8007830
30 January 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7857268
13 December 2023
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7838559
14 August 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7767850
14 June 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7715284
31 May 2023
Uninspected Other
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7701768
31 May 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7701912
30 May 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7701147
22 May 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7693874
20 May 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7692876
20 May 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7693971
19 May 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692372
5 May 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7681454
1 May 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7679121
26 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676270
21 February 2023
Deficiency Check · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7639268
13 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7622232
1 October 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7569752
14 September 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7558701
25 March 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7418398
20 February 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7401164
17 February 2022
PSC B · COC-CHEM Annual
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7395199
12 January 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7379090
17 August 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7289633
9 August 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7282870
19 June 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7229483
27 February 2021
COC-CHEM & TVE Renew · PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7147208
24 February 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7145735
23 February 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7144762
12 November 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7094096
30 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7087470
29 October 2020
MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7086586
30 September 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7070330
29 September 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7067712
2 September 2020
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7048289
14 May 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6953174
25 March 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6931566
1 March 2020
PSC B · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6914345
7 February 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6904903
29 August 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6798318
20 February 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6628678
5 October 2018
Ballast Water Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6555518
26 September 2018
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6549781
27 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6524348
11 June 2018
In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6441404
2 March 2018
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6363059
21 February 2018
COE-Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6358933
12 January 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6337291
8 January 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6334107
6 January 2018
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6333542
4 November 2017
COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6305527
1 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6298973
13 September 2017
COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6265584
9 September 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6263134
3 April 2017
COE-Dockside
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6115983
23 February 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6093126
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 January 2026
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed 14 unauthorized temporary repairs on the vessels high pressure water-mist piping system, with 02 active leaks while in operation. RO has issued a condition of class valid for 30 days to allow for permanent repair.
74SOLAS(24)
II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2026
Resolved 1 March 2026
Resolution: Verified repairs and recieved class report attesting to proper operation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 January 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The technical and operational nature of deficiencies 2,3,4,5,6 and 7 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release of detention.
74SOLAS(24) IX/3.1
ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 January 2026
Resolution: Received class ISM report.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2026
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed 14 unauthorized temporary repairs on the vessels high pressure water-mist piping system, with 02 active leaks while in operation. Additionally, PSCO observed the ships crew conducted a water mist system inspection on 17OCT2025 including inspection of all piping for damage/corrosion without any indication of unauthorized temporary repairs.
74SOLAS(24)
II-2/14.2.1.2
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2026
Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable product. PSCO observed 02 exposed wires on electrical sensor component near cargo discharge pump in the vessel's pump room.
74SOLAS(24) VII/10.1
IBC 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 20 January 2026
Resolved
Ships carrying toxic or flammable products or both shall be equipped with at least two instruments designed and calibrated for testing the specific vapors in question. PSCO observed the vessel’s Chief Mate improperly calibrating the portable gas detector “EAGLE 2” in a manner that contradicts the manufacturer’s instructions.
74SOLAS(24) VII/10.1
IBC 13.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2026
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in areas, special precautions against such risks shall be taken to the satisfaction of the administration. PSCO observed multiple improperly maintained deck lighting in hazardous zone forward of vessels pump room entrance, indicating to not be explosion proof.
74SOLAS(24)
II-1/45.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed unauthorized repairs on vessels boiler fuel piping.
74SOLAS(24)
II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 January 2026
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Except as provided in regulation 14(2), such covers shall be weathertight and fitted with gaskets and clamping devices. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. PSCO observed emergency escape hatch from engineering store room leading to aft deck not weathertight.
ICLL (88 prot)
16(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 January 2026
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. PSCO identified improperly maintained electrical sensor cabling in vessel boiler room.
74SOLAS(24)
II-1/45.5.6
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2026
Resolution: Received class report attesting to repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 20 January 2026
Resolved
An IOPP Certificate shall be issued, after an initial or renewal survey in accordance with the provisions of regulation 6 of this annex. Vessel's IOPP supplement was marked indicating the vessel had SOPEP when it should have been marked SMPEP.
MARPOL(20)
I/7.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 20 January 2026
Resolution: IOPP certificate updated by class during exam.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 September 2024
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with regulation XI/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Sector Northern New England Command Center received a report from the pilot of a potential grounding of the PALANCA RIO east of the Casco Bay bridge in Portland, ME. Coast Guard is requiring class documentation attesting to the structural integrity of the vessel's hull prior to departure.
74SOLAS(2004)II-1/3-1
40ac
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2024
Resolved 26 September 2024
Resolution: ABS approved diver was able to attend the vessel and verify that coatings were intact and no indentations or other damage were identified at this time.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 1 May 2023
Resolved
On each tanker of 10,000 gross tons or more that is subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability
33CFR164.37(b)
50 c - extended to 30JUN2023
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 14 June 2023
Resolution: Vessel agent provided copies of completed work order for the S-band radar repairs signed by the service engineer and Master of the PALANCA RIO, the interim survey statment from Class concerning the S-band radar. and valid Cargo Ship Safety Equipment cert.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 April 2023
Resolved
S Band radar not spinning/ scanning and will return to standby mode when turn on.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 April 2023
Resolved 30 April 2023
Resolution: Vessel equipped with a 2nd X-band radar to compensate for the S-band until spare parts from the maker arrive (approx. 6 weeks). Approved by Flag and surveyed by Class.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 February 2023
Resolved
06107 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention. PSCO observed thermal oil leaking on cargo line 052, a rag soaked with thermal oil, and thermal oil leaking on the #5 port trace head inlet drop line in the cargo control room.
74 SOLAS (20) I/11(a)
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2023
Resolution: Rectified by crew and verified by class, see report.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 21 February 2023
Resolved
09219 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. There was deteriorated lagging on the thermal pipe heating line and thermal oil outlet pump line in the cargo pump room.
74 SOLAS (20) I/11(a)
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2023
Resolution: Rectified by crew and verified by class, see report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 February 2023
Resolved
06199 - The cargo's containment system must have a high level alarm that can be seen and heard on the open deck. The vessel did not have a high level alarm on deck.
46 CFR 153.409(b)
40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2023
Resolution: Rectified by crew and verified by class, see report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 February 2023
Resolved
06199 - The cargo's containment system must have a high level alarm marked "HIGH LEVEL ALARM." The vessel did not have a high level alarm on deck.
46 CFR 153.406(d)
40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2023
Resolution: Rectified by crew and verified by class, see report.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 24 February 2022
Resolved
THE OIL DISCHARGE MONITORING AND CONTROL SYSTEM SHALL BE DESIGNED AND INSTALLED IN COMPLIANCE WITH THE GUIDLINES AND SPECIFICATIONS FOR OIL DISCHARGE MONITORING AND CONTROL SYSTEMS FOR OIL TANKERS DEVELOPED BY THE ORGANIZATION. VESSEL SELF REPORTS ODME FLOWMETER INOPERATIVE. USAGE NOT PERMITTED.
MARPOL I/31.3 Action 50 a, c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 March 2022
Resolution: Received report from classification society requiring repairs be made IAW their Letter of Intervention.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 February 2021
Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCO observed fuel leaks on the STBD fuel pump and the lagging around the fuel control valves on #2 and #5 cylinders completely saturated. Additionally, PSCO observed hydraulic oil accumulating around the exhaust valves on all 6 cylinder heads.
74 SOLAS (14) II-2/4.1.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2021
Resolution: Recevied class report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2021
Resolved
11117 - All life-saving appliances shall be fitted with retro-reflective material where it will assist with detection. The retro-reflective tape on the lifeboat was deteriorated rendering it ineffective.
74 SOLAS (14) III/34
LSA 1.2.2.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2021
Resolution: Recevied class report attesting to repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 27 February 2021
Resolved
06106 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed thermal heating oil leaking from the ACG 014 line valve in the cargo pump room. The oil was observed actively leaking as well as leaking through the insulation.
74 SOLAS (14) I/ii(a)
Prior to Cargo Operations ac
Action required: 705 - Other - as specified
Resolved 28 February 2021
Resolution: Recevied class report attesting to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 October 2020
Resolved
15109 - Safety Management System - The company should ensure that inspections are held at appropriate intervals. PSCO observed the monthly calibration test for the ODME record keeping is inconsistent between the ORB Part II and ODME printout folder and the computer database from January 2020 to October 2020. SOLAS 74 (2014 CONS.) IX/Reg 3.1 & ISM Code 10.2.1. 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2020
Resolved 12 November 2020
Resolution: Recieved message from class attesting to corrective action
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 September 2020
Resolved
Steering gear control system shall be operable from the navigation bridge. Vessel's main steering gear follow-up is malfunctioning and failing at irregular intervals.
74SOLAS(14 CONS) II-1/29.7 Action taken: 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2020
Resolved 4 September 2020
Resolution: Item was repaired to the satisfaction of class and coast guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2018
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control.
The vessel's electronic control system is not operating as designed. Prove proper operation of vessel's propulsion system.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Resolution: Fixed and cleared by class society/ Coast Guard.
Personnel › Training › Tank Ship Familiarization
Issued 23 February 2017
Resolved
[name withheld] displayed a lack of knowledge regarding the vessel's ODME system & cargo pump operations.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: The Adminstration engage with [name withheld] to take corrective action to the satisfaction of the USCG PSCO.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 23 February 2017
Resolved
Overboard discharge valve open/closure status was unable to be verified by the onboard monitoring system.
Action required: 15 - Rectify deficiencies by next port
Due 28 February 2017
Resolved 6 March 2017
Resolution: Class conducted evaluation and test to system. Noted all operational with issue. Discrepancy cleared.