MAURY USCG vessel records
← All vessels

HERTA

HERTA is a freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in October 2022, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2022. Most recent: inspection, 18 October 2022.

Built
Not recorded
Last inspected
18 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 October 2022
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9535151
1388626
Flag
PORTUGAL
Maury page id
psix-1388626

Documentation record

Tonnage as PSIX records it59307 - Convention (Subpart B), Gross Ton
31361 - Convention (Subpart B), Net Ton
71407 - Dead Weight, Metric Ton
94191 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

18 October 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7579417
3 December 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7361713
1 December 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7360435
14 November 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6299017
28 September 2016 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6011696
28 September 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6018339
13 June 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5908670
9 June 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5901206

Deficiency record · 2

Operations/Management › Vessel Activity › Underway
Issued 28 September 2016 Resolved
When approaching berth, vessel experienced a loss of control over the propulsion engine from the starboard control wing. The telegraph control was not fully in the "stop" position, which set off the abnormal working alarm. For unkown reasons, the breaker switch opened, and had to be reset prior to normal operations
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 September 2016
Resolved 4 October 2016
Resolution: Recieved class report stating statisfactory test of the M/E control system was completed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 June 2016 Resolved
10c. The following three "A" class self-closing fire doors did not close as required by the vessel's fire control plan: E-Deck pipe duct, E-Deck cable duct, & D-Deck cable duct. 74 SOLAS (09 Cons. Ed.) Ch. II-2 Reg. 15.2.4
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.