MAURY USCG vessel records
← All vessels

MARLIN AQUAMARINE

MARLIN AQUAMARINE is a 2016 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in March 2026, along with 2 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 25 March 2026.

Built
2016
Last inspected
25 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9721906
1388839
Flag
MARSHALL ISLANDS
Maury page id
psix-1388839

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2016–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it49999 - Dead Weight, Metric Ton
60949 - Displacement, Metric Ton
29669 - Convention (Subpart B), Gross Ton
14293 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

25 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8332010
24 January 2026 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8301149
19 January 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8296230
31 January 2025 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8072770
31 January 2025 COE-Administrative · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8072986
30 January 2025 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8072160
30 January 2025 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8072416
5 December 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8039299
17 September 2024 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8003924
17 September 2024 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8003970
11 October 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7818733
10 October 2023 Deficiency Check · In-Service Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7799414
22 November 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7098013
4 June 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6703408
27 May 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6695762
21 May 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6689504
12 September 2017 ISPS II Exam · COC-CHEM & TVE Renew · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6264837
26 July 2016 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5949447

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 11 October 2023 Resolved
For tankers of 20,000 tonnes deadweight and upwards constructed on or after 1 July 2002 but before 1 January 2016, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the FSS Code. PSCO was informed that the ship's IGG is not operational due to unknown reasons. 74 SOLAS (20) II-2/4.5.5.1.1 705 AC (Prior to cargo discharge)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2023
Resolution: The faulty PLC is replaced, tested by maker and found in order as per the submitted service report.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 26 July 2016 Resolved
1899 Tankers (Other): Condition of ship and its equipment shall be maintained to conform with the provisions of the Code to ensure that the ship will remain fit to precede to sea without presenting an unreasonable threat or harm to marine environment. PSCO observed overfill devices for all cargo tanker were not operational. -SOLAS VII/10.1, IBC 1.5.3.1, 33CFR 155.480 - Prior to cargo
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2016
Resolution: Overfill devices serviced by Complete Marine Services. Replaced faulty PCB Board. All overfill alarms tested Sat. Service report submitted to USCG.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.