T. NEVBAHAR is a 2009 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in October 2017, along with 6 deficiencies and 6 operational controls.
Records from 2016 to 2017. Most recent: inspection, 11 October 2017.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it11545 - Dead Weight, Metric Ton 8482 - Regulatory (Subpart C or D), Gross Ton 15958 - Displacement, Metric Ton 8482 - Convention (Subpart B), Gross Ton 3742 - Regulatory (Subpart C or D), Net Ton 3742 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
11 October 2017COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285374
20 August 2017ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-CHEM & TVE Annual · Administrative Inspection
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 20 August 2017Resolved
1850 - Upon testing of deck foam monitors on the main fire pump, the two aft monitors did not provide adquate coverage of the intersecting deck area. Also, when shutting off the system, the aft foam monitor isolation valve broke. In its current state, the delivery of fixed fire fighting water/foam to the cargo deck would be inadequate to fight a fire. SOLAS(14)II-2/10.8.1.3 FSS Code 14.2.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Witnessed satisfactory operation of all foam monitors.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 20 August 2017Resolved
1835 - The pressure monitoring alarm system in the CCR does not have an audible alarm and would not alert the crew to high/low pressure alarms for cargo tanks. IBC Code 8.3.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Witnessed operation of audible alarm for cargo tank pressure alarm system.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 20 August 2017Resolved
1840 - High level and overfill audible alarm on deck was inoperable. 46 CFR 39.2007(a) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 20 August 2017
Resolution: Crew repaired audible alarm for high and overill alarms.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 13 July 2017Resolved
See Narative and special notes
Action required: 705 - Other - as specified
Resolved 28 July 2017
Resolution: Vessel was granted an extension of compliance by CG-OES. See special Note
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 13 July 2017Resolved
See narative.
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 23 August 2017
Resolution: Received e-mail confirmation of updates to BWM plan.
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 20 August 2017
Resolution: Deficiency rectified.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.