MAURY USCG vessel records
← All vessels

CMA CGM AMAZON

CMA CGM AMAZON is a 2014 freight ship. The Coast Guard has recorded 10 inspections since 2018, most recently in March 2026, along with 14 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 16 March 2026.

Built
2014
Last inspected
16 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9706308
9HA5144
1389457
Flag
MALTA
Maury page id
psix-1389457

Documentation record

Tonnage as PSIX records it96424 - Convention (Subpart B), Gross Ton
59714 - Convention (Subpart B), Net Ton
115534 - Dead Weight, Metric Ton
146354 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

16 March 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8324575
12 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8325235
6 March 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8320922
1 November 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7581590
11 August 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7029831
7 August 2020 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7026335
11 December 2019 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6871785
11 January 2019 Ballast Water Examination · ISPS III Exam · ISM Exam · NPV Safety Exam · MARPOL Annex I Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6609320
11 January 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610572
7 November 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6576222

Deficiency record · 14

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 January 2019 Resolved
Oil filtering equipment shall comply with paragraph 6 of this regulation and be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization. Vessel did not have on board complete copies of the Operating and Maintenance manuals for the 15 ppm Bilge Alarm and the Oil Content Meters as required by MEPC.107(49). -MARPOL ANNEX I/14.7 -17ac-
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2019 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO identified unattached reach-rod on valve BSE02 located in forward bilge of engine room. PSCO also found missing hardware on the reach-rod to the overboard discharge valve from the clean drain pump. Reach-rod could be disconnected by hand and the overboard discharge valve could be operated without removal of the tamper seal or chain securing the reach-rod. -74SOLAS(14)I/11(b) -17ac-
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 January 2019 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO identified unattached ground wire from STBD Lifeboat spotlight. -74SOLAS(14)II-1/40.3 -10c-
Action required: 10 - Deficiency Rectified
Resolved 17 January 2019
Resolution: Ground wire appropriately attached to spotlight.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 January 2019 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO identified unauthorized hold-back device on B-15 classed door leading to galley. -74SOLAS(14)II-2/9.4.2 -10c-
Action required: 10 - Deficiency Rectified
Resolved 17 January 2019
Resolution: Hold back removed from self-closing door.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 16 January 2019 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Ship’s Safety Management System manual part 3 gives instructions for any non-conformance that affects the safety of the crew and environment. Ship’s defect report No. 137 dated 10JAN2018 indicates fuel oil leaking in the pipe duct. PSCO identified problem has continually persisted to present. -74SOLAS(14)IX/3.1 -ISM CODE 9.1 -30abc- The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Ship’s Safety Management System manual part 3 gives instructions for any non-conformance that affects the safety of the crew and environment. PSCO identified soft patch on HFO fuel transfer piping in forward engine room bilge. Chief Engineer was onboard for period of 3 Months. Cause for the soft patch on fuel line was not reported. -ISM CODE 9.1 The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Ship’s Safety Management System manual part 3 gives instructions for any non-conformance that affects the safety of the crew and environment. PSCO discovered objective evidence of oily water being transferred to, stored, and discharged overboard through the clean drain tank. Tank is not authorized for such use and was not reported to company, class, or flag. -ISM CODE 9.1
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 January 2019 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO witnessed excessive heavy fuel oil accumulation in the pipe duct beneath cargo hold 06. PSCO witnessed 10-12 inches of HFO pooling in areas of pipe duct caused by leaks from multiple couplings. Ship defect report No. 137 indicates this condition was caused by a leak of an undetermined amount occurring for an undetermined amount of time, but at least since 10JAN2018 when report No.137 was generated. -74SOLAS(14)II-2/4.2.2 -30abc-
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 January 2019 Resolved
After any survey of the ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, without the sanction of the Administration, except the direct replacement of such equipment and fittings. Using a portable pump and associated hoses, vessel's crew transferred to, and stored oily bilge water in, the clean drain tank through the tank top. The clean drain tank is not identified by the IOPP as an approved tank for the retention of oily bilge water. -MARPOL ANNEX I/6.4.2 -30abc-
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 16 January 2019 Resolved
Subject to the provisions of regulation 4 of this Annex and paragraphs 2, 3, and 6 of this regulation, any discharge into the sea of oil or oily mixtures from ships shall be prohibited. Vessel’s crew discharged oily bilge water without processing through oil filtering equipment. Oily bilge water was transferred from various bilge sources via a portable pump and hose arrangement to the clean drain tank, and then discharged overboard from the clean drain tank through the clean drain pump. Additionally, clean drain tank installed oil content meter was not operated properly. Sample drain line was plugged with a screw, impeding any sample fluid flow to oil content meter sampling equipment. Crew made statements as to pouring bottled water into sensor to ensure sensor had a reading of below set point to continually operate clean drain pump. PSCO witnessed oily residue present in clean drain pump strainer and discharge pipe spool piece after installed 3-way valve overboard. -MARPOL ANNEX I/15.1 -30abc-
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 16 January 2019 Resolved
Subject to the provisions of regulation 4 of this Annex and paragraphs 2, 3, and 6 of this regulation, any discharge into the sea of oil or oily mixtures from ships shall be prohibited. During the operational test of the OWS, PSCO discovered objective evidence of tampering with the system including a missing bolt from the outlet flange to the bilge holding tank of the 3-way simulation valve and identified missing seal to sampling cock drain valve as required by ship’s operating procedures posted on OWS coalescer. During expanded MARPOL exam, PSCO opened overboard discharge piping and discovered oily residue inside the piping. -MARPOL ANNEX I/15.1 -30abc-
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2019 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO identified fiberglass soft patch on HFO fuel transfer lines in forward engine room bilge. Soft patch is in vicinity of valves OF012 and OF013. Chief engineer stated he has no recollection of when soft patch was installed. Chief engineer has been onboard approximately 3 months. -74SOLAS(14)II-1/26.1 -17ac-
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 January 2019 Resolved
Openings in the shell plating below the deck limiting the vertical extent of damage shall be kept permanently closed while at sea. PSCO identified unsecured tank top covers to the following tanks: Clean drain, Sludge holding, Waste oil, and Bilge water holding. -74SOLAS(14)II-1/24.1 -17ac-
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 January 2019 Resolved
After any survey of the ship under article 14 has been completed, no change shall be made in the structure, equipment, arrangements, materials or scantlings covered by the survey. PSCO identified loose and missing bolts on main deck engine room maintenance hatch. ICLL (88 PROTO) art 15 -17ac-
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 11 January 2019 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: The crew failed to fully implement the requirements of the ISM code through their SMS procedures. These identified deficiencies are evidence that the ship and/or company are not meeting the SMS requirements. Recommend external audit. -74SOLAS(14)IX/3.1 -ISM CODE 2.2 -30abc- The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Standard Work Practices which require enclosed/confined space entry permit dated 26NOV2018 for the purpose of cleaning and inspecting pipe duct for leaks is missing atmospheric testing, personnel logs, and continuous atmospheric monitoring. The safe working practices listed in chapter 7 of the Ship Operations Manual referenced by the Ship’s Safety Management System Manual identifies specific requirements for enclosed/confined space entry. -ISM CODE 2.2 The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. PSCO identified tamper seal on the OWS sample cock drain valve was not installed as required by ship operating manual chapter 6, section 1.5 “A seal shall be used to secure in closed position the draining cock of the sampling line connected to the discharge line of the OWS. The number of the seal shall be recorded in the ORB under operational code “I”… When draining cock is required to be opened for maintenance and or sampling/draining purposes, a record of the opening of this cock is also to be made under Operation Letter Code “I”. For example; Draining cock of sampling line to OCM unsealed for maintenance / and or sampling or draining, whilst the overboard OWS sea valve kept closed.” The ship operating manual is referenced by the ship’s safety management system manual. -ISM CODE 2.2
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 January 2019 Resolved
The Oil Record Book Part 1 shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship: Discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces. Crew did not record discharge of oily bilge water overboard from the clean drain tank via the clean drain pump in the Oil Record Book Part 1. -MARPOL ANNEX I/17.2.4 -30abc-
Action required: 30 - Ship detained
Resolved 24 January 2019
Resolution: Class report submitted to our office addressing the noted deficiency and found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.