Records from 2016 to 2026. Most recent: inspection, 6 April 2026.
Documentation record
Registered dimensions (L × B × D)35.0 ft × 11.0 ft × 4.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2016
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portRIGGINS, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
6 April 2026
COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8343856
13 May 2025
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8139128
26 June 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7946751
23 May 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7702110
7 June 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7478685
6 April 2021
Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7170052
31 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021308
20 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685599
9 May 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402778
2 May 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6134073
23 June 2016
Hull Examination · Plan Review "T" Boat · Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5910666
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 May 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vsl was missing alcohol test equipment.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2025
Resolved 27 May 2025
Resolution: test strips placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2021
Resolved
A vessel of more than 26 feet in length, but not more than 19.8 meters 65 feet, must carry a minimum of one life buoy of not less than 24 inches which is approved IAW 46CFR160.050. No life buoy found onboard during inspection. Prior to the carriage of passengers, to the satisfaction of the USCG, place onboard an approved Life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2021
Resolved 21 June 2021
Resolution: Received Correspondence from Owner indicating the an approved ring buoy was placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Only 36 lifejackets could be located during the exam. Vessel limited to 36 passengers until 41 approved, adult life jackets are placed onboard IAW the vessel's COI, to the satisfaction of the USCG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2021
Resolved 21 June 2021
Resolution: Received Correspondence from Owner indicating the missing lifejackets had been found and placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021
Resolved
Each life jacket carried on board a vessel must be marked in accordance with 46CFR185.60. 09 Lifejackets onboard were not marked with the vessel's name. Within 30 days prove to the satisfaction of the USCG that all lifejackets in service on the vessel are properly marked IAW with 46CFR185.60.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 21 June 2021
Resolution: Received Correspondence from Owner indicating the lifejackets were marked IAW with the CFR.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 15 April 2021
Resolved
The vessel will have mounted at the operating station, emergency instructions containing the actions to be taken in the event of probable emergencies specific to the operation of the vessel; and placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Within 30 days, to the satisfaction of the USCG properly outfit vessel with required placards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 21 June 2021
Resolution: Received Correspondence from Owner indicating the Sterns donning placard had been placed into service.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 15 April 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit onboard contained expired consumables. Within 30 days, to the satisfaction of the USCG place into service suitable, serviceable replacements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 21 June 2021
Resolution: Received Correspondence from Owner indicating an approved first aid kit was place into service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2018
Resolved
JS01: Provide servicing report for portable fire extinguishers and Fireboy system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2018
Resolved 12 June 2018
Resolution: Received Fire servicing report for Owner.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 May 2018
Resolved
JS02: Provide copy of Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2018
Resolved 11 September 2018
Resolution: Received confirmation from the NVDC that a new COD has been issued.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 May 2018
Resolved
JS03: Prove proper operation of fume detector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2018
Resolved 12 June 2018
Resolution: Received statement from the Owner stating the issue was resolved. A video demonstrating the proper operation of the Fume Detector was provided to substantiate this.