Records from 2016 to 2026. Most recent: inspection, 12 February 2026.
Inspection history · 37
12 February 2026
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8308236
4 February 2026
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8303451
10 July 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8178521
27 June 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8166440
15 May 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8133079
15 May 2025
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8136950
15 May 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8155764
5 May 2025
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8127265
26 April 2025
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8120528
26 April 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8310295
17 April 2025
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8113094
29 January 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8071099
11 July 2024
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7952670
4 January 2024
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7844458
2 June 2023
Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7703845
2 June 2023
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7703885
3 November 2022
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7583321
15 August 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7533857
5 August 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7525530
1 August 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7522219
25 March 2022
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7417748
22 September 2021
Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7315315
19 March 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7158115
9 September 2020
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7051265
12 February 2020
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6906400
8 August 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6774660
20 April 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6668557
14 February 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6625931
7 December 2018
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6593569
24 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587041
24 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587531
1 August 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6495252
3 July 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6467568
26 July 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6217668
21 June 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6182073
30 August 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5996396
25 July 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5952688
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 February 2026
Resolved
EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES APPROVAL BY ADMINISTRATION. A SECOND SOURCE OF ENERGY SHALL BE PROVIDED UNLESS MANUAL STARTING CAN BE DEMONSTRATED. PSCO OBSERVED CREW UNABLE TO SWITCH SECONDARY MEANS OF POWER TO THE EMERGENCY GENERATOR, PREVENTING SECONDARY STARTING MEANS.
SOLAS (04) II-1/44.2 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2026
Resolution: CLASS REPORT AND MASTER STATEMENT RECEIVED. CLEARED BY EMAIL ON 05FEB2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2026
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS TO NOT CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED ELECTRICAL INSTALLATION ON LIGHT FIXTURE THAT WAS NOT PART OF THE ELECTRICAL CIRCUIT.
SOLAS (04)II-1/45.1.3 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2026
Resolved 20 March 2026
Resolution: RO/RSO REPORT RECEIVED
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2026
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS TO NOT CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED 02 WASHERS AND 01 DRYER HOOKED UP IN STAIRWELL LEADING TO ENGINE CONTROL ROOM.
SOLAS (04) II-1/45.1.3 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 February 2026
Resolution: REMOVED THE WASHERS AND DRYER FROM THE SPACE AND PUT INTO THE DESIGNATED LAUNDRY CATEGORY SPACE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 27 June 2025
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD, DUE REGARD BEING PAID TO HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED EXCESSIVE OIL-SOAKED LAGGING AROUND THE DUPLEX FUEL FILTERS ADJACENT TO FUEL BOOSTER PUMPS CREATING A CLEAR FIRE HAZARD.
74 SOLAS (04) II-1/26.1 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2025
Resolution: VESSEL REPLACED THE LAGGING WITH NEW LAGGING.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 June 2025
Resolved
WHENEVER A DEFECT IS DISCOVERED WHICH EFFECTS THE SAFETY OF A SHIP OR THE EFFICIENCY OR COMPLETENESS OF ITS LIFESAVING APPLIANCES OR OTHER EQUIPMENT, THE MASTER OR OWNER OF THE SHIP SHALL REPORT AT THE EARLIEST OPPORTUNITY TO THE ADMINISTRATION, THE NOMINATED SURVEYOR OR RECOGNIZED ORGANIZATION RESPONSIBLE FOR ISSUING THE RELEVANT CERTIFICATE, WHO SHALL CAUSE INVESTIGATIONS TO BE INITIATED TO DETERMINE WHETHER A SURVEY IS NECESSARY. [name withheld], AND THROUGH DISCUSSIONS WITH THE CREW DETERMINED THAT THE DUPLEX FUEL PRELIMINARY FILTERS WERE BEING CLEARED MULTIPLE TIMES DAILY. UPON DETAILED INVESTIGATIONS, PSCO DISCOVERED THE MARKER'S NSTRUCTIONS STATES CLEANING SHOULD BE CONDUCTED EVERY 750 HOURS AND THE SHIP MAINTENANCE PLAN STATES THEY SHOULD BE CONDUCTED EVERY 3 MONTHS. THE VESSEL FINDING IT NECESSARY TO CHANGE UP TO 5 OR MORE TIMES DAILY INDICATES SUBSTANTIAL DEFECT IN THE EFFICIENCY COMPARED TO MAKER RECOMMENDATIONS. RECOMMEND CLASS SURVEY TO DETERMINE ROOT CAUSE.
74 SOLAS(20) I/11(C) 40AC
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2025
Resolution: Recevied Class Survey attesting to the satisfactory rectification of the Deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 27 June 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 4 July 2025
Resolution: Received internal audit from vessel showing causation of issues and identifying solutions to resolve internal issues.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 June 2025
Resolved
ALL RESCUE BOATS SHALL BE VISUALLY INSPECTED TO ENSURE THAT THEY ARE READY TO USE, TO INCLUDE THEIR ATTACHMENT TO THE LIFEBOAT. PSCO OBSERVED SAFETY RACHET STRAPS HOLDING THE RESCUE BOAT TO THE STOWAGE LOCATION WERE RUSTED AND SEIZED PREVENTING READY RELEASE AND LAUNCHING FROM THE SHIP. ADDITIONALLY, VESSEL RESCUE BOAT TENDING LINE RELEASE HOOK WAS SEIZED AND WOULD NOT RELEASE THROUGH PROPER METHODS, REQUIRING TO BE PRIED OPEN.
74 SOLAS () III/20.6.1 10C
Action required: 10 - Deficiency Rectified
Resolved 27 June 2025
Resolution: RACHET STRAP WAS REPLACED AND THE TENDING LINE RELEASE HOOK WAS EXERCISED AND FIXED.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service which they are intended. PSCO observed that vessel suffered loss of propulsion with malfunction of both DGs.
74 SOLAS (04)II-1/25.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2025
Resolved 23 May 2025
Resolution: Received extensive survey report and verbally confirmed with class surveyor that defective items had been replaced. repaired, and confirmed in working order.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 May 2025
Resolved
Each emergency generator generating set arranged to be automatically started shall be equipped with starting devices appoved by Administration. A second source of energy shall be provided unless manual starting can be demonstrated. PSCO observed the generator can not be started by the second battery set.
74 SOLAS (04 Cons.) Ch. II-1 Reg 44.2
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2025
Resolved 6 May 2025
Resolution: Class report: Replaced faulty cable between the battery charger and the engine governor. The emergency generator engine was then tested in manual mode, using each battery group separately. During testing, each battery group successfully started engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 May 2025
Resolved
Maintenance, testing, and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. PSCO observed broken and corroded bolts for the most forward hatch, nearest to the bow of the freefall lifeboat.
74 SOLAS (20 Cons.) Ch. III / Reg. 20.3.1
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2025
Resolved 6 May 2025
Resolution: Class Report: Corroded bolts on the most forward hatch of the freefall lifeboat had been replaced with new bolts. See attached class report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2025
Resolved
Electrical installations shall be such that: The safety of crew and ship from electrical hazards will be ensured. PSCO observed multiple electrical glands in conduit boxes, dry rotted or missing, throughout the engine room.
74 SOLAS (04 Cons.) Ch-II-1 / Reg. 40.1.3
50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2025
Resolved 6 May 2025
Resolution: Class report: All empty glands on the distribution boards were properly sealed to prevent electrical hazards and ensure the safety of the crew. See attached Class report
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed grounding wire not properly connected to the electrical winch for the gangway on the port side of the vessel.
74 SOLAS (04 Cons.) Ch. II-1 Reg 45.1.3
10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 5 May 2025
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 May 2025
Resolved
All external openings leading to compartments assumed intact in the damage analysis, which are below the final damage waterline, are required to be watertight. PSCO observed the watertight hatch of the emergency egress from the steering gear room was not watertight, and could see light while fully closed.
74 SOLAS (04 Cons.) Ch. II-1 Reg 25-10.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 5 May 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service which they are intended. PSCO observed that the MDE woudl not start due to unknown issue while cylinders were in bottom dead center position.
74 SOLAS (04) II-1/25.1
60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2025
Resolution: Class Survey Receieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2025
Resolved
Means shall be provided to ensue that the machinery can be brought into operation from the dead ship condition without external aid. PSCO observed failure of engine to start due to governor malfunction. 17ac.
74SOLAS(04)II-1/26.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2025
Resolution: Received class report attesting to satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2025
Resolved
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED EXCESSIVE VIBRATIONS OF HYDRAULIC STEERING GEAR UNIT WHILE OPERATING PUMP NUMBER 2 DURING STEERING GEAR TEST.
SOLAS04 CONS ED. II-1/29.2.1
17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2025
Resolution: Upon review of the Class survey/ Technician report, vessel has been cleared of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2025
Resolved
WHERE NECESSARY NONCONDUCTING MATS OR GRATINGS SHALL BE PROVIDED AS THE FRONT AND REAR OF THE PROVIDED AT THE FRONT AND REAR OF THE SWITCHBOARD. PSCO OBSERVED NON-CONDUCTIVE MATTING MISSING IN FRONT OF 13 ELECTRICAL PANELS THROUGHOUT ENGINE ROOM AND ADJOINING SPACES.
SOLAS04 CONS ED. II-1/45.2
10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 January 2025
Resolution: Corrected during exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2025
Resolved
MAIN AND EMERGENCY SWITCHBOARD SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS AS MAY BE NEEDED TO APPARATUS AND EQUIPMENT, WITHOUT DANGER TO PERSONNEL. PSCO OBSERVED EXCESSIVE STORAGE BEHIND ELECTRICAL PANELS IN THE ENGINE CONTROL ROOM LIMITING ACCESSIBILITY.
SOLAS04 CONS ED. II-1 / 45.2
17C
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2025
Resolution: REMOVED EXCESSIVE STORAGE AND CORRECTED ON THE SPOT.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 January 2024
Resolved
11110 - Life Saving Appliances - Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the painter line on the starboard liferaft was not connected to the "weak-link" on the HRU.
74SOLAS(20)Cons. III/20.2
10C
Action required: 10 - Deficiency Rectified
Resolved 4 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 January 2024
Resolved
11104 - Life Saving Appliances - Cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code. PSCO observed the rescue boat's painter line was not attached to the quick-release on the bow. The rescue boats search-light was also inoperable.
74SOLAS(20)Cons. III/31.2
10C
Action required: 10 - Deficiency Rectified
Resolved 4 January 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 September 2021
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions. In meeting these requirements the company should ensure that any non-conformity is reported and appropriate corrective action is taken. Vessel reported inoperable main generator to the company on 25MAY21. Company did not report the issued to flag or class and the vessel still has an inoperable main generator.
74SOLAS(20)IX/3.1
ISM COde 10.1
ISM Code 10.2
16 a, c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 12 October 2021
Resolution: Received class report clearing the deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO Observed a soft patch on the sea water cooling line for the jacket water on the main engine.
74SOLAS(04)I/11(a)
16 a, c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 12 October 2021
Resolution: Received class report clearing the deficiency.