← All vessels
HIGH SPIRITS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named HIGH SPIRITS
HIGH SPIRITS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1988, most recently in April 2025, along with 90 deficiencies, 1 operational control and 4 casualty investigations between 2014 and 2024.
Records from 1988 to 2025. Most recent: inspection, 23 April 2025.
- Built
- 1975
- Last inspected
- 23 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 90 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2014–2024
Identity
570240
WDK7886
139177
Flag
UNITED STATES
368088810
Maury page id
psix-139177
Inspections, by type
…with no type recorded13
Years with a record
30 calendar years (1988–2025)
The 55 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)56.3 ft × 17.1 ft × 9.7 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS CRAFT CORP · HOLLAND, MI, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMOSS LANDING, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 September 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK7886MMSI 368088810 · active · compulsorily equipped · granted 20 April 2019, expires 20 April 2029
WCY9807MMSI 367394730 · expired · compulsorily equipped · granted 11 February 2009, cancelled 8 June 2019
WCJ7052MMSI not assigned · expired · voluntarily equipped · granted 14 July 1994, cancelled 26 September 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 55
23 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113641
5 December 2024
Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043135
10 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7937009
9 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7891885
1 May 2023
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7678621
8 December 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7604960
19 April 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7433529
24 March 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7148293
10 December 2020
Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7105691
17 January 2020
Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891521
1 April 2019
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653961
13 December 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6596456
4 April 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6384602
14 December 2016
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6056953
24 June 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5952883
15 December 2015
COI Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5777172
13 May 2014
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4858870
13 February 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4243345
11 January 2011
Construction Oversight · COI Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3919758
8 December 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3906195
18 September 2008
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3327034
13 July 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2993868
14 July 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2712772
12 July 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2710441
12 June 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2677673
11 July 2005
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423221
12 October 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2285916
8 June 2004
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2092686
15 September 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1902499
19 September 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1677898
11 July 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1644808
12 July 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423610
13 July 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454834
31 August 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781051
23 August 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781708
2 August 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1109649
2 August 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1110305
2 July 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450320
13 July 1998
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372298
25 June 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400795
2 April 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788388
15 January 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 695794
11 July 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378110
16 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 213634
16 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 216320
16 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 216675
16 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 228963
25 March 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387952
25 March 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404118
2 May 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367363
28 September 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 48264
28 September 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 695795
30 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137194
6 May 1994
Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370808
22 July 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1210411
Deficiency record · 90
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2025
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement. MI observed chaffing on fuel lines in the Engine Room.
46 CFR 182.455 (b)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. There was a fuel leak found in the centerline void space. Clean fuel.
46 CFR 182.100
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Identified several dead end wires without caps/tape to in the console of the upper pilothouse.
46 CFR 183.200
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 23 April 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire. No instructions posted for local operation of the fire suppression system.
46 CFR 185.510 (a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2025
Resolved
A vessel must carry one floating waterlight attached to the ring life buoy. The battery in the light for the ring life buoy was expired.
46 CFR 180.70 (d) (1)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 April 2025
Resolved
Ship station license present for operation of all maritime services transmitting equipment on board a vessel. FCC Radio telephony certificate was expired.
47 CFR 80.13 (b)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificates onboard were expired.
46 CFR 10.301
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 April 2025
Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12. Medications in the first aid kit were expired.
46 CFR 199.175 (b)(10)(i)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Vapor tight boundary is not maintained due to a hole in void aft of the engine room.
46 CFR 177.405(c)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Identified three dead end wires without caps/tape to prevent from accidental electrical shock.
46 CFR 183.200
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 April 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Identified expired drug alcohol swabs on board.
46 CFR 4.06-15
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023
Resolved
All wiring and cables shall be suitable for marine service and for particular installation used. Dead-end electrical wires are located in multiple spaces.
46 CFR 183.10-20(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 May 2023
Resolved
A hatch cover must have securing devices. Hatch located in forward crew accommodation does not have securing devices. Effect repairs to the satisfaction of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2023
Resolved
At each initial and subsequent inspection for certification and re-inspection the inspector shall examine and test all items in the ship's outfit, such as ground tackle, navigation lights, compass, etc., which are required to be carried by the regulations in this sub-chapter. Navigation lights are inoperable.
46 CFR 176.25-40(a)
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 December 2022
Resolved
Each pressure type wire connector and lug must meet UL 486A (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: (1) The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration; and (2) Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit - MI found a loose wire in the vicinity of the bilge space underneath port side deck. Request owner/operator to secure the wire IAW 46 CFR 183.340(i)(1).
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 December 2022
Resolved
Electrical equipment on a vessel must be maintained and installed to protect passengers, crew, and other persons and the vessel from electrical hazards. Vessel had several loose wiring from inoperable electrical equipment and dead end wires. Vessel shall clear all dead end wiring, disconnected from power sources, and make all possible attempts to remove the wiring from the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 24 March 2021
Resolved
A vessel on limited coastwise route must carry six red hand flare distress signals and six orange smoke signals. Vessel has seven red flares and 2 orange smoke signals.
46 CFR 180.68(a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 March 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessel's visual indicators for high level bilge alarms are not operable.
46 CFR 182.530(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 March 2021
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel has a flex hose penetrating the second forward-most watertight bulkhead without any watertight sealant.
46 CFR 179.320(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 March 2021
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. Each ring life buoy must be approved in accordance with 160.150 in subchapter Q of this chapter. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Vessel's ring life buoy is not in a serviceable condition, including the grab line, which are significantly deteriorated.
46 CFR 180.170(a)(2)
46 CFR 180.170(b)(1)
46 CFR 160.050-3(c)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 March 2021
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's IBA painter was not connected to the float free link.
46 CFR 180.130(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2021
Resolved
A carbon dioxide cylinder may not be inclined more than 30° from the vertical unless fitted with flexible or bent siphon tubes, in which case it may be inclined not more than 80° from the vertical. Vessel's fixed firefighting carbon dioxide bottle is inclined past 30° and does not have an indication of being fitted with a siphon tube.
46 CFR 181.410(c)(7)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 January 2020
Resolved
A vessel on a limited coastwise route must carry six red flares approved IAW 160.021 and six orange smoke distress signals approved IAW 160.037. Vessel is missing 3 red and 3 orange flares or approved substitutions. 46CFR180.68
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 21 January 2020
Resolved
Each space accessible to passengers or used by crew on a regular basis must have at least two means of escape. Emergency escapes in aft berthing areas overheads have no ladders or means for a passenger to climb out. Provide means for passenger to climb out of emergency escapes. 46 CFR 177.15
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2020
Resolved
Wiring where subject to mechanical damage shall be protected IAW the National Electrical Code. Wire run for engineroom high water alarm, engineroom U-lube system, wire in aft engine room above the racor assembly are not secured and installed properly creating the possibility for wire chaffing. 46 CFR 183.05-50 (a)(2)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 January 2020
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Port Engineroom bulkhead has through hull penetration that is not watertight. 46CFR171.114(a)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Lighting cable located starboard side forward bulkhead next to entrance of engine room has exposed splice utilizing twist connectors. 46 CFR 183.10-20
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019
Resolved
At each vessel inspection, hazardous situations must be corrected. Vessel sign limiting 11 passengers to upper deck is missing. 46 CFR 184.502
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 April 2019
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel is missing FCC License and Safety Certificate. 46 CFR 184.502
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry up to date charts, coast pilot, light list, and tide tables. Charts, Light List, and Coast Pilot are not current. 46 CFR 184.420 (a)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 April 2019
Resolved
The installation of a fire extinguisher must be to the satisfaction of the Officer in Charge, Marine Inspections. Galley fire extinguisher and bracket is not mounted. 46 CFR 181.520
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 April 2019
Resolved
On a vessel engaged on excursion type operations, rails shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Rail courses have gaps near 12 inches near bottom and top courses of rail. 46 CFR 177.35-1 (c)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 April 2019
Resolved
All machinery installed must be maintained to afford adequate protection from machinery failure. Both ram seals leaking on steering ram. 46 CFR 182.01-5
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 April 2019
Resolved
Suitable rails shall be installed in way of all exposed hazards. Port side rail for upper deck ladder is loose where it mounts to the helm dash. 46 CFR 177-35-15
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019
Resolved
At each inspection, the marine inspector shall require hazardous situations to be corrected. Port Window 4th aft from bow is cracked.
Communications › Radio Communications › EPIRB
Issued 22 March 2017
Resolved
EPIRB hydro sticker missing and battery expired.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 March 2017
Resolved
Alcohol Testing Kit expired
Engineering › Bilge Water Management System › Pump
Issued 11 January 2016
Resolved
Found several sub electric bilge pumps without UL approval stamp. Provide prooof of UL approved electric submerssible pumps in required spaces.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 January 2016
Resolved
Due to vsl high freeboard, recovery of unconcious oscar was not achieved. Prove satisfactory recovery of oscar man overboard to attending marine inspector.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 January 2016
Resolved
Provide a repair proposal to address installation of closure for natural ventilation to machinary space, and effect approved repairs.
Stability › Weathertight Integrity › General
Issued 11 January 2016
Resolved
Engine room has 2 installed port lights, 1 port side, 1 stbd side. Both located within 30 in. of lightweight vessel condition. Provide a repair proposal to make permantly watertight.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 January 2016
Resolved
Install a machinary guard on the generator alternator belt to prevent injury.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 11 January 2016
Resolved
Provide current nautical chart and publications for vsl's route.
Stability › Weathertight Integrity › General
Issued 15 December 2015
Resolved
The hatch cover to the lazarette is rotted and not water tight. Provide repair proposal to repair and make watertight.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 13 May 2014
Resolved
Provide proof of merchant mariners credential for the appropriate route and tonnage of the vessel. 46 CFR 185.402
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 May 2014
Resolved
PROVE PROPER INSTALLATION OF PORT FORWARD DECK RAIL THROUGH BOLT.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 May 2014
Resolved
PROVIDE GUARDS FOR ENGINE ROOM LIGHT BULBS. 46 CFR 183.410
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 May 2014
Resolved
REPLACE RETRO-REFLECTIVE TAPE AND FILL EXPOSED FOAM ON BOTH 15 PAX LIFEFLOATS.
Fire Fighting › Fire Bucket › Quantity
Issued 13 May 2014
Resolved
PROVIDE 03 FIRE BUCKETS. 46 CFR 181.610
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 May 2014
Resolved
PROVIDE SERVICING REPORT FOR C02 SYSTEM. 46 CFR 181.410
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 May 2014
Resolved
PROVIDE CURRENT EDITIONS OF LIGHT LIST AND COAST PILOT. 46 CFR 184.920
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2012
Resolved
Provide the following missing items as required in the first aid kit: Ammonia Inhalants, Iodine Applicators, and Aspirin.
Engineering › Fuel Oil Service System › Filter
Issued 13 February 2012
Resolved
Replace plastic plugs on RACOR fuel filters with metal plugs.
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 February 2012
Resolved
Make emergency fuel tank shut off valve more readily accessible to be activated.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 February 2012
Resolved
Properly repair Eng Room broken 110 VAC outlet
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2008
Resolved
Replace household wires extending from main diesel engines to gauges with marine grade wiring IAW 46CFR183.340.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2008
Resolved
Replace plastic ties used for hose and wire support in engine room with metal hose clamps IAW 46CFR182.40.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 September 2008
Resolved
Replace plastic through hull fitting in space second from the bow with appropriate metallic fitting IAW 46CFR183.340.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 July 2007
Resolved
Vessel did not have Nav rules, Light List, or Coast Pilot on board. Vessel must keep navigation publication on vessel.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 13 July 2007
Resolved
Bouyant Apparatus must be labeled have lanyards to each oar.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 13 July 2007
Resolved
Starboard shaft packing was leaking, required to adjust packing by tightening
Lifesaving › Lifefloat › Paddle
Issued 11 July 2006
Resolved
Vessel name was not marked on the lifefloat paddles.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2006
Resolved
Floating electric waterlight bracket was not serviceable. Told to replace with acceptable bracket.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 July 2006
Resolved
Wrong ship name and port on required lifebuoy.
Engineering › Lubricating Oil Service System › Gauge
Issued 11 July 2005
Resolved
Found port main propulsion engine lube oil pressure gauge at operating station inoperable.
Lifesaving › Lifefloat › Painter
Issued 11 July 2005
Resolved
Seapainter and float free link were not connected and missing from lifefloats.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 11 July 2005
Resolved
Inoperable float lights on both bouyant apparatus.
Lifesaving
Issued 15 September 2003
Resolved
Upgrade MOB recovery device; lifesling w lifting gear or similar.
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 September 2003
Resolved
Upgrade 1st aid kit to USCG standard.
Fire Fighting › Remote Fuel Shutoff
Issued 15 September 2003
Resolved
Prove proper operation of remote F/O shutdowns.
Lifesaving › Hand Flares
Issued 15 September 2003
Resolved
Add visual distress signals as required for route.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 15 September 2003
Resolved
Conduct U/W operational test of machinery and steering. (Not witnessed during this exam)
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 September 2003
Resolved
Conduct emergency drills.
Construction/Loadline › Hull
Issued 15 September 2003
Resolved
Conduct drydock exam for credit, prior to carrying passengers.
Lifesaving
Issued 12 July 2001
Resolved
INSTALL ONE ADDITIONAL WATER LIGHT SUCH THAT EACH LIFEFLOAT HAS ONE WATERLIGHT ATTACHED. THIS SHALL BE COMPLETE BY 12AUG01.
Lifesaving
Issued 12 July 2001
Resolved
EQUIP AND STORE LIFEFLOATS IN ACCORDANCE WITH 46 CFR 180.137 AND 180.175. THIS SHALL INCLUDE (A) STENCILING VSL NAME ON FLOATS (B) ADDING ADDITIONAL PADDLE PER LIFEFLOAT (C) INSTALLING SPACERS IN BETWEEN FLOATS (D) REMOVING WIRE TIES ON LIFE LINES.
Construction/Loadline
Issued 13 July 2000
Resolved
LOCATE SOURCE OF WATER FOUND IN AFTER BILGE AREA. FIX AND REPAIR SOURCE OF WATER IN THIS AREA._x001C_ _x001C_
Construction/Loadline
Issued 13 July 2000
Resolved
ALL BILGE HIGH LEVEL ALARMS ARE NOT OPERATING. REPAIR OR REPLACE BILGE SENSORS, INSPECT ALL WIRING LEADING TO BILGE SENSORS AND REPLACE OR REPAIR WIRING.
Accommodation/Occupational Safety
Issued 13 July 2000
Resolved
WATER PRESSURE TANK IN ENGINEROOM NOT SECURED, MOUNT TANK AND MOTOR SECURELY TO DECK.
Fire Fighting
Issued 2 July 1999
Resolved
INSTALL A DISCHARGE ALARM AT THE CONTROL PANNEL OR A HEAT DETECTION ALARM AND REMOVE THE AUTOMATIC DISCHARGE.
Fire Fighting
Issued 2 July 1999
Resolved
INSTALL SHUT DOWNS FOR POWER VENTILLATION IN THE CASE OF FIXED FIRE FIGHTING AGENT DISCARGE.
Fire Fighting
Issued 2 July 1999
Resolved
SHORE HOLE LOCATED BELOW LADDER TO ER TO PREVENT UNCONTOLLED VENTILLATION IN THE CASE OF A ER FIRE.
Navigation
Issued 25 June 1998
Resolved
FIX AND CALIBRATE RUDDER ANGLE INDICATOR LOCATED ON THE FLYING BRIDGE.
Electrical
Issued 25 June 1998
Resolved
REMOVE ALL DISCONNECTED ELECTRICAL WIRES FROM BELOW FLYING BRIDGE CONTROL STATION.
Engineering
Issued 25 June 1998
Resolved
INSTALL FUEL IMPINGEMENT BOWL AND METALLIC PLUG ON FUEL FILTER IN THE ENGINE ROOM.
Electrical
Issued 25 June 1998
Resolved
REPLACE WIRE NUTS LOCATED BELOW THE FLYING BRIDGE CONTROL STATION AND IN THE STEERING GEAR SPACE WITH PROPER WIRE CONNECTIONS.
Engineering
Issued 11 July 1997
Resolved
INSTALL MISSING RACOR FUEL FILTER METAL IMPINGEMENT BOWLS LOCATED ON AFT ENGINEROOM BULKHEAD.
Lifesaving
Issued 11 July 1997
Resolved
DEMONSTRATE A MAN OVERBOARD DRILL UTILIZING EQUIPMENT ONBOARD TO EFFECTIVELY RETRIEVE A PERSON FROM THE WATER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Lifesaving
Issued 11 July 1997
Resolved
INSTALL PROTECTIVE GUARDS ON (MD168-3) COMPRESSOR PULLEY AND ON PORT/STBD FWD ENGINE PULLEYS.
Electrical
Issued 11 July 1997
Resolved
DEMONSTRATE PROPER OPERATION OF THE STBD GENERATOR._x001C_
Casualty record · 4
26 July 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 4936911
15 March 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5086856
24 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5952883
10 June 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7937009
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.