HIGH SPIRITS

HIGH SPIRITS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1988, most recently in April 2025, along with 90 deficiencies, 1 operational control and 4 casualty investigations between 2014 and 2024.

Records from 1988 to 2025. Most recent: inspection, 23 April 2025.

Built
1975
Last inspected
23 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7886
139177
Flag
UNITED STATES
368088810
Maury page id
psix-139177

Inspections, by type

…with no type recorded13
Years with a record 30 calendar years (1988–2025)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.3 ft × 17.1 ft × 9.7 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS CRAFT CORP · HOLLAND, MI, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMOSS LANDING, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 September 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7886MMSI 368088810 · active · compulsorily equipped · granted 20 April 2019, expires 20 April 2029
WCY9807MMSI 367394730 · expired · compulsorily equipped · granted 11 February 2009, cancelled 8 June 2019
WCJ7052MMSI not assigned · expired · voluntarily equipped · granted 14 July 1994, cancelled 26 September 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

23 April 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113641
5 December 2024 Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043135
10 June 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7937009
9 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7891885
1 May 2023 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7678621
8 December 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7604960
19 April 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7433529
24 March 2021 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7148293
10 December 2020 Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7105691
17 January 2020 Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891521
1 April 2019 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653961
13 December 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6596456
4 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6384602
14 December 2016 Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6056953
24 June 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5952883
15 December 2015 COI Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5777172
13 May 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4858870
13 February 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4243345
11 January 2011 Construction Oversight · COI Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3919758
8 December 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3906195
18 September 2008 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3327034
13 July 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2993868
14 July 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2712772
12 July 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2710441
12 June 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2677673
11 July 2005 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423221
12 October 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2285916
8 June 2004 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2092686
15 September 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1902499
19 September 2002 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1677898
11 July 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1644808
12 July 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423610
13 July 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454834
31 August 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781051
23 August 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781708
2 August 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1109649
2 August 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1110305
2 July 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450320
13 July 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372298
25 June 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400795
2 April 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788388
15 January 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 695794
11 July 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378110
16 May 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 213634
16 May 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 216320
16 May 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 216675
16 May 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 228963
25 March 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387952
25 March 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404118
2 May 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367363
28 September 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 48264
28 September 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 695795
30 June 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137194
6 May 1994 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370808
22 July 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1210411

Deficiency record · 90

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2025 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement. MI observed chaffing on fuel lines in the Engine Room. 46 CFR 182.455 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 8 May 2025
Resolution: Mechanic came on board to replenish the chaffed fuel lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. There was a fuel leak found in the centerline void space. Clean fuel. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: Fuel in the centerline void is cleaned and crew advised not to overfill the fuel tanks or put 100% fuel next time to prevent the spill from air vent
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Identified several dead end wires without caps/tape to in the console of the upper pilothouse. 46 CFR 183.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 8 May 2025
Resolution: Electricians are coming on Monday May 12th at 1:30 pm to take care off the dead end wires in upper pilothouse.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 23 April 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire. No instructions posted for local operation of the fire suppression system. 46 CFR 185.510 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: Fire Suppression System instructions is printed and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2025 Resolved
A vessel must carry one floating waterlight attached to the ring life buoy. The battery in the light for the ring life buoy was expired. 46 CFR 180.70 (d) (1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: Battery in ring light is replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 April 2025 Resolved
Ship station license present for operation of all maritime services transmitting equipment on board a vessel. FCC Radio telephony certificate was expired. 47 CFR 80.13 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: FCC cert reissued exp 2030
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2025 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificates onboard were expired. 46 CFR 10.301
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: Medical certificate on board
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 April 2025 Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12. Medications in the first aid kit were expired. 46 CFR 199.175 (b)(10)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 9 May 2025
Resolution: First aid items replaced.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Vapor tight boundary is not maintained due to a hole in void aft of the engine room. 46 CFR 177.405(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 April 2024
Resolution: Verified photos.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Identified three dead end wires without caps/tape to prevent from accidental electrical shock. 46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 April 2024
Resolution: Verified removed dead end wires.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 April 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Identified expired drug alcohol swabs on board. 46 CFR 4.06-15
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 April 2024
Resolution: Verified alcohol strips.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
All wiring and cables shall be suitable for marine service and for particular installation used. Dead-end electrical wires are located in multiple spaces. 46 CFR 183.10-20(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 6 July 2023
Resolution: Attended vessel to confirm removal of dead end wires from fwd accomodation space, closet, and closet in passageway below main deck (fwd) of heads.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 May 2023 Resolved
A hatch cover must have securing devices. Hatch located in forward crew accommodation does not have securing devices. Effect repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 6 July 2023
Resolution: Hatch properly secured. Attended to verify.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2023 Resolved
At each initial and subsequent inspection for certification and re-inspection the inspector shall examine and test all items in the ship's outfit, such as ground tackle, navigation lights, compass, etc., which are required to be carried by the regulations in this sub-chapter. Navigation lights are inoperable. 46 CFR 176.25-40(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 6 July 2023
Resolution: Verified operation of all nav-lights.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 December 2022 Resolved
Each pressure type wire connector and lug must meet UL 486A (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: (1) The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration; and (2) Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit - MI found a loose wire in the vicinity of the bilge space underneath port side deck. Request owner/operator to secure the wire IAW 46 CFR 183.340(i)(1).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 1 January 2023
Resolution: Master properly secured the wire.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 December 2022 Resolved
Electrical equipment on a vessel must be maintained and installed to protect passengers, crew, and other persons and the vessel from electrical hazards. Vessel had several loose wiring from inoperable electrical equipment and dead end wires. Vessel shall clear all dead end wiring, disconnected from power sources, and make all possible attempts to remove the wiring from the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 1 January 2023
Resolution: Master removed all dead end wiring.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 24 March 2021 Resolved
A vessel on limited coastwise route must carry six red hand flare distress signals and six orange smoke signals. Vessel has seven red flares and 2 orange smoke signals. 46 CFR 180.68(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: Operator obtained four additional red flares, bringing the total to eleven red hand flares and two orange smoke signals.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 March 2021 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessel's visual indicators for high level bilge alarms are not operable. 46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 April 2021
Resolution: Received photographic evidence of bilge alarm light working for all spaces.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 March 2021 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel has a flex hose penetrating the second forward-most watertight bulkhead without any watertight sealant. 46 CFR 179.320(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 April 2021
Resolution: Received picture of penetration in question properly sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 March 2021 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. Each ring life buoy must be approved in accordance with 160.150 in subchapter Q of this chapter. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Vessel's ring life buoy is not in a serviceable condition, including the grab line, which are significantly deteriorated. 46 CFR 180.170(a)(2) 46 CFR 180.170(b)(1) 46 CFR 160.050-3(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 April 2021
Resolution: Operator replaced life ring and properly rigged life line and floating light to life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 March 2021 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's IBA painter was not connected to the float free link. 46 CFR 180.130(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 24 March 2021
Resolution: Operator properly secured painter to hydrostatic release weak link prior to MI departure from vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2021 Resolved
A carbon dioxide cylinder may not be inclined more than 30° from the vertical unless fitted with flexible or bent siphon tubes, in which case it may be inclined not more than 80° from the vertical. Vessel's fixed firefighting carbon dioxide bottle is inclined past 30° and does not have an indication of being fitted with a siphon tube. 46 CFR 181.410(c)(7)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: Vessel provided a schematic of the CO2 bottle, which indicates a siphone tube.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 January 2020 Resolved
A vessel on a limited coastwise route must carry six red flares approved IAW 160.021 and six orange smoke distress signals approved IAW 160.037. Vessel is missing 3 red and 3 orange flares or approved substitutions. 46CFR180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2020
Resolved 22 January 2020
Resolution: 6 additional Red Flares that meet 46 CFR 160.021 were provided.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 21 January 2020 Resolved
Each space accessible to passengers or used by crew on a regular basis must have at least two means of escape. Emergency escapes in aft berthing areas overheads have no ladders or means for a passenger to climb out. Provide means for passenger to climb out of emergency escapes. 46 CFR 177.15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 20 March 2020
Resolution: Escape ladder provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2020 Resolved
Wiring where subject to mechanical damage shall be protected IAW the National Electrical Code. Wire run for engineroom high water alarm, engineroom U-lube system, wire in aft engine room above the racor assembly are not secured and installed properly creating the possibility for wire chaffing. 46 CFR 183.05-50 (a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 20 March 2020
Resolution: Properly installed wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 January 2020 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Port Engineroom bulkhead has through hull penetration that is not watertight. 46CFR171.114(a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 5 March 2020
Resolution: Holes in bulkhead made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Lighting cable located starboard side forward bulkhead next to entrance of engine room has exposed splice utilizing twist connectors. 46 CFR 183.10-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
Resolution: Junction box installed and wires spliced in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019 Resolved
At each vessel inspection, hazardous situations must be corrected. Vessel sign limiting 11 passengers to upper deck is missing. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: Signage installed limiting 8 passengers to the upperdeck.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 April 2019 Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel is missing FCC License and Safety Certificate. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 April 2019 Resolved
As appropriate for the intended voyage, a vessel must carry up to date charts, coast pilot, light list, and tide tables. Charts, Light List, and Coast Pilot are not current. 46 CFR 184.420 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: Updated navigation publications provided.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 April 2019 Resolved
The installation of a fire extinguisher must be to the satisfaction of the Officer in Charge, Marine Inspections. Galley fire extinguisher and bracket is not mounted. 46 CFR 181.520
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: Fire Extinguisher mounted in bracket.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 April 2019 Resolved
On a vessel engaged on excursion type operations, rails shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Rail courses have gaps near 12 inches near bottom and top courses of rail. 46 CFR 177.35-1 (c)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 July 2019
Resolution: Vessel owner provided netting over spacing between rails.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 April 2019 Resolved
All machinery installed must be maintained to afford adequate protection from machinery failure. Both ram seals leaking on steering ram. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: Ram Seals replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 April 2019 Resolved
Suitable rails shall be installed in way of all exposed hazards. Port side rail for upper deck ladder is loose where it mounts to the helm dash. 46 CFR 177-35-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2019
Resolution: Rails were tighted leading to upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019 Resolved
At each inspection, the marine inspector shall require hazardous situations to be corrected. Port Window 4th aft from bow is cracked.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 16 September 2019
Resolution: Received documentation from Delta Glass of window replacement. Window was replaced with Laminated Safety Glass.
Communications › Radio Communications › EPIRB
Issued 22 March 2017 Resolved
EPIRB hydro sticker missing and battery expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2017
Resolved 24 March 2017
Resolution: Owner replaced EPIRB and installed new hydrostatic release unit.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 March 2017 Resolved
Alcohol Testing Kit expired
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Corrected on the spot
Engineering › Bilge Water Management System › Pump
Issued 11 January 2016 Resolved
Found several sub electric bilge pumps without UL approval stamp. Provide prooof of UL approved electric submerssible pumps in required spaces.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 25 August 2016
Resolution: All bilge pumps (2 in foward engine compartment and 1 under main passagewat) were replaced with UL approved devices.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 January 2016 Resolved
Due to vsl high freeboard, recovery of unconcious oscar was not achieved. Prove satisfactory recovery of oscar man overboard to attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 22 March 2017
Resolution: Verified newly installed winch and recovery system valid.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 January 2016 Resolved
Provide a repair proposal to address installation of closure for natural ventilation to machinary space, and effect approved repairs.
Condition: Invalid
Due 11 February 2016
Resolved 9 March 2017
Resolution: Ventillation cover installed and inspected satisfactory.
Stability › Weathertight Integrity › General
Issued 11 January 2016 Resolved
Engine room has 2 installed port lights, 1 port side, 1 stbd side. Both located within 30 in. of lightweight vessel condition. Provide a repair proposal to make permantly watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 25 August 2016
Resolution: Engine port lights were made watertight with custom fabricated aluminum plugs fastened to the hull and sealed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 January 2016 Resolved
Install a machinary guard on the generator alternator belt to prevent injury.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 9 March 2017
Resolution: Guards over generator installed.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 11 January 2016 Resolved
Provide current nautical chart and publications for vsl's route.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 25 August 2016
Resolution: Updated charts and publications are on board.
Stability › Weathertight Integrity › General
Issued 15 December 2015 Resolved
The hatch cover to the lazarette is rotted and not water tight. Provide repair proposal to repair and make watertight.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 6 September 2016
Resolution: Alluminium watertight hatch with securing latches (dogs) and saftey chain installed.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 13 May 2014 Resolved
Provide proof of merchant mariners credential for the appropriate route and tonnage of the vessel. 46 CFR 185.402
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2014
Resolution: Vessel provided proof of valid merchant mariner for operation on Near Coastal waters.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 May 2014 Resolved
PROVE PROPER INSTALLATION OF PORT FORWARD DECK RAIL THROUGH BOLT.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 15 December 2014
Resolution: Attended vessel for drydock, saw that the vessel had installed the port foward deck rail through bolt.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 May 2014 Resolved
PROVIDE GUARDS FOR ENGINE ROOM LIGHT BULBS. 46 CFR 183.410
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 6 January 2015
Resolution: Found same problem during drydock on 12/15/14. Recieved pictures on 01/06/15 that showed the new guards had been put on.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 May 2014 Resolved
REPLACE RETRO-REFLECTIVE TAPE AND FILL EXPOSED FOAM ON BOTH 15 PAX LIFEFLOATS.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 15 December 2014
Resolution: Found retroreflective tape on lifefloats satisfatory.
Fire Fighting › Fire Bucket › Quantity
Issued 13 May 2014 Resolved
PROVIDE 03 FIRE BUCKETS. 46 CFR 181.610
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 15 December 2014
Resolution: Saw new fire buckets
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 May 2014 Resolved
PROVIDE SERVICING REPORT FOR C02 SYSTEM. 46 CFR 181.410
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 15 December 2014
Resolution: Saw servicing report for their CO2 system.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 May 2014 Resolved
PROVIDE CURRENT EDITIONS OF LIGHT LIST AND COAST PILOT. 46 CFR 184.920
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2014
Resolved 15 December 2014
Resolution: Verified that vessel had current light list and coast pilot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2012 Resolved
Provide the following missing items as required in the first aid kit: Ammonia Inhalants, Iodine Applicators, and Aspirin.
Due 1 March 2012
Resolved 28 March 2012
Resolution: Owner/Operator provide receipt of purchase of missing items.
Engineering › Fuel Oil Service System › Filter
Issued 13 February 2012 Resolved
Replace plastic plugs on RACOR fuel filters with metal plugs.
Due 1 March 2012
Resolved 28 March 2012
Resolution: Owner/Operator provided receipt of purchase of new metal plugs
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 February 2012 Resolved
Make emergency fuel tank shut off valve more readily accessible to be activated.
Due 1 March 2012
Resolved 28 March 2012
Resolution: Owner/Operator provided a cut out in the carpet and handles on access panel making fuel shut off valve more readily accessible.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 February 2012 Resolved
Properly repair Eng Room broken 110 VAC outlet
Due 1 March 2012
Resolved 28 March 2012
Resolution: Owner/Operator provided pictures of new 110 Outlet cover
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2008 Resolved
Replace household wires extending from main diesel engines to gauges with marine grade wiring IAW 46CFR183.340.
Action required: 705 - Other - as specified
Due 18 October 2008
Resolved 17 October 2008
Resolution: Household wires replaced with Marine Grade Wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2008 Resolved
Replace plastic ties used for hose and wire support in engine room with metal hose clamps IAW 46CFR182.40.
Action required: 705 - Other - as specified
Due 18 October 2008
Resolved 17 October 2008
Resolution: Zip ties were replaced with metal hose clamps for wire support.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 September 2008 Resolved
Replace plastic through hull fitting in space second from the bow with appropriate metallic fitting IAW 46CFR183.340.
Action required: 705 - Other - as specified
Due 18 October 2008
Resolved 17 October 2008
Resolution: Plastic through hull was replaced with welded metallic fitting.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 July 2007 Resolved
Vessel did not have Nav rules, Light List, or Coast Pilot on board. Vessel must keep navigation publication on vessel.
Due 20 July 2007
Resolved 17 July 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 13 July 2007 Resolved
Bouyant Apparatus must be labeled have lanyards to each oar.
Due 20 July 2007
Resolved 17 July 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 13 July 2007 Resolved
Starboard shaft packing was leaking, required to adjust packing by tightening
Due 20 July 2007
Resolved 17 July 2007
Lifesaving › Lifefloat › Paddle
Issued 11 July 2006 Resolved
Vessel name was not marked on the lifefloat paddles.
Due 11 July 2006
Resolved 11 July 2006
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2006 Resolved
Floating electric waterlight bracket was not serviceable. Told to replace with acceptable bracket.
Condition: Improper Installation
Due 11 July 2006
Resolved 11 July 2006
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 July 2006 Resolved
Wrong ship name and port on required lifebuoy.
Due 11 July 2006
Resolved 11 July 2006
Resolution: Corrected on the spot.
Engineering › Lubricating Oil Service System › Gauge
Issued 11 July 2005 Resolved
Found port main propulsion engine lube oil pressure gauge at operating station inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 14 July 2005
Lifesaving › Lifefloat › Painter
Issued 11 July 2005 Resolved
Seapainter and float free link were not connected and missing from lifefloats.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 14 July 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 11 July 2005 Resolved
Inoperable float lights on both bouyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 14 July 2005
Lifesaving
Issued 15 September 2003 Resolved
Upgrade MOB recovery device; lifesling w lifting gear or similar.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 September 2003 Resolved
Upgrade 1st aid kit to USCG standard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2004
Resolved 15 September 2003
Fire Fighting › Remote Fuel Shutoff
Issued 15 September 2003 Resolved
Prove proper operation of remote F/O shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2004
Lifesaving › Hand Flares
Issued 15 September 2003 Resolved
Add visual distress signals as required for route.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 15 September 2003 Resolved
Conduct U/W operational test of machinery and steering. (Not witnessed during this exam)
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 12 July 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 September 2003 Resolved
Conduct emergency drills.
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 12 July 2005
Construction/Loadline › Hull
Issued 15 September 2003 Resolved
Conduct drydock exam for credit, prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 8 June 2004
Lifesaving
Issued 12 July 2001 Resolved
INSTALL ONE ADDITIONAL WATER LIGHT SUCH THAT EACH LIFEFLOAT HAS ONE WATERLIGHT ATTACHED. THIS SHALL BE COMPLETE BY 12AUG01.
Condition: Unknown
Due 12 August 2001
Resolved 18 February 2004
Lifesaving
Issued 12 July 2001 Resolved
EQUIP AND STORE LIFEFLOATS IN ACCORDANCE WITH 46 CFR 180.137 AND 180.175. THIS SHALL INCLUDE (A) STENCILING VSL NAME ON FLOATS (B) ADDING ADDITIONAL PADDLE PER LIFEFLOAT (C) INSTALLING SPACERS IN BETWEEN FLOATS (D) REMOVING WIRE TIES ON LIFE LINES.
Condition: Unknown
Due 12 July 2001
Resolved 7 August 2001
Construction/Loadline
Issued 13 July 2000 Resolved
LOCATE SOURCE OF WATER FOUND IN AFTER BILGE AREA. FIX AND REPAIR SOURCE OF WATER IN THIS AREA._x001C_ _x001C_
Condition: Unknown
Due 15 July 2000
Resolved 17 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
ALL BILGE HIGH LEVEL ALARMS ARE NOT OPERATING. REPAIR OR REPLACE BILGE SENSORS, INSPECT ALL WIRING LEADING TO BILGE SENSORS AND REPLACE OR REPAIR WIRING.
Condition: Unknown
Due 15 July 2000
Resolved 17 July 2000
Accommodation/Occupational Safety
Issued 13 July 2000 Resolved
WATER PRESSURE TANK IN ENGINEROOM NOT SECURED, MOUNT TANK AND MOTOR SECURELY TO DECK.
Condition: Unknown
Due 15 July 2000
Resolved 17 July 2000
Fire Fighting
Issued 2 July 1999 Resolved
INSTALL A DISCHARGE ALARM AT THE CONTROL PANNEL OR A HEAT DETECTION ALARM AND REMOVE THE AUTOMATIC DISCHARGE.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 2 July 1999 Resolved
INSTALL SHUT DOWNS FOR POWER VENTILLATION IN THE CASE OF FIXED FIRE FIGHTING AGENT DISCARGE.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 2 July 1999 Resolved
SHORE HOLE LOCATED BELOW LADDER TO ER TO PREVENT UNCONTOLLED VENTILLATION IN THE CASE OF A ER FIRE.
Condition: Unknown
Due 16 July 1999
Resolved 14 July 1999
Navigation
Issued 25 June 1998 Resolved
FIX AND CALIBRATE RUDDER ANGLE INDICATOR LOCATED ON THE FLYING BRIDGE.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 25 June 1998 Resolved
REMOVE ALL DISCONNECTED ELECTRICAL WIRES FROM BELOW FLYING BRIDGE CONTROL STATION.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 25 June 1998 Resolved
INSTALL FUEL IMPINGEMENT BOWL AND METALLIC PLUG ON FUEL FILTER IN THE ENGINE ROOM.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 25 June 1998 Resolved
REPLACE WIRE NUTS LOCATED BELOW THE FLYING BRIDGE CONTROL STATION AND IN THE STEERING GEAR SPACE WITH PROPER WIRE CONNECTIONS.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 11 July 1997 Resolved
INSTALL MISSING RACOR FUEL FILTER METAL IMPINGEMENT BOWLS LOCATED ON AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 10 September 1997
Resolved 22 October 1997
Lifesaving
Issued 11 July 1997 Resolved
DEMONSTRATE A MAN OVERBOARD DRILL UTILIZING EQUIPMENT ONBOARD TO EFFECTIVELY RETRIEVE A PERSON FROM THE WATER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 10 September 1997
Resolved 22 October 1997
Lifesaving
Issued 11 July 1997 Resolved
INSTALL PROTECTIVE GUARDS ON (MD168-3) COMPRESSOR PULLEY AND ON PORT/STBD FWD ENGINE PULLEYS.
Condition: Unknown
Due 10 September 1997
Resolved 22 October 1997
Electrical
Issued 11 July 1997 Resolved
DEMONSTRATE PROPER OPERATION OF THE STBD GENERATOR._x001C_
Condition: Unknown
Due 10 September 1997
Resolved 22 October 1997

Casualty record · 4

26 July 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 4936911
15 March 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5086856
24 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5952883
10 June 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7937009
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.