Records from 2016 to 2018. Most recent: inspection, 31 July 2018.
Inspection history · 9
31 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6498903
29 July 2018
Deficiency Check · ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6491312
3 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6405003
23 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6377137
1 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6363814
12 August 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6233979
11 August 2017
Ballast Water Examination · Administrative Inspection · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6237215
9 November 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038507
24 June 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5917755
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2018
Resolved
74 SOLAS (04) II-1/26.7:
17 abc
The engine room was observed to be insufficiently clean with excessive oil in the bilge.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Engine room was cleaned.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 July 2018
Resolved
74 SOLAS (04) II-1/17.2:
17 abc
Oily water separator overboard valve is leaking into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. OWS piping and valve repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 July 2018
Resolved
74 SOLAS (04) II-1/43.3.1.2:
17 abc
Emergency generator starter is inoperable. Emergency generator can only be started manually.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Ships crew installed new starter, inspectors witnessed e-gen test, includautomatic starting, sat.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 29 July 2018
Resolved
74 SOLAS (14) II-2/2.2.5.2:
17 abc
Jacketing on external high pressure fuel lines to the number 5 and6 cylinders of main engine was observed to be excessively worn and leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Ships crew repaired high pressure fuel line jacketing.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 July 2018
Resolved
74 SOLAS (14) III 16.4.3:
17 abc
The general emergency alarm is not audible in the crew accommodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Technician installed additional sirens on accommodation decks. Inspectors witnessed GE alarm test, all sat
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 July 2018
Resolved
74 SOLAS (14) ii-2/ 9.7.3.1.2
17 abc
Fire dampener in the fuel oil spare (purifier room) is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Inspectors observed operational fire dampeners.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2018
Resolved
74 SOLAS (14) II-2/10.10.1.1 FSS code 3.2.1.1
17 abc
Fire fighting suits are torn in several areas.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Ship aquired two new fire fighting suits.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 July 2018
Resolved
74 SOLAS (14) III 134 LSA code 5.1.1.1.0
17 abc
Rescue boat is fitted with a modification to the bilge pumping system that does not prevent water ingress into the rescue boat.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2018
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. Ships crew made repairs to prevent ingress of water.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 July 2018
Resolved
74 SOLAS (14) I/II a:
17 abc
Oily water separator overboard piping has multiple pin hole leaks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Deficiencies written to Flag, Class and Coast Guard. Received reports from Flag and Class and Coast Guard went aboard to observe deficiency cleared. OWS piping and valve repaired.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 August 2017
Resolved
1410 - Operation/Management - The Purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: .1 Means shall provide to control leaks of flammable liquids. PSCO observed fuel leaking in the vicinity of the main engine #6 cylinder fuel pump. 74solas(2004)II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2017
Resolved 13 August 2017
Resolution: The fuel leak was repaired. Main engine tested with no signs of any leaks.
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 11 August 2017
Resolved
0750-Oil fuel pipes,which if damaged, would alllow oil to escape from a storage,setting or daily service tank having a capacity of 500L and above,shall be fitted with a cock or valve directly on the tank capable of being closed from a safe posotion outside the space.PSCO observed the emer generator service tank remote fuel shutoff valve shutdown cable to be broken.74solas(04)II-2/4.2.2.3.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2017
Resolved 13 August 2017
Resolution: The emergency generator remote fuel shutoff valve was repaired.