SILVER MANOORA is a 2016 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in February 2025, along with 7 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 24 February 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13768 - Convention (Subpart B), Net Ton 49897 - Dead Weight, Metric Ton 60247 - Displacement, Metric Ton 29375 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
24 February 2025PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8080345
21 December 2023PSC B · COC-CHEM Annual · Administrative Inspection
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 13 December 2020Resolved
The company should ensure that appropriate corrective action is taken.
The company should ensue that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations, codes, and guidelines.
In reference to deficiency #02, PSCO observed and reviewed documents for new lights for inoperable fixtures on the ship. Deficient item was reported to company in October. Vessel and company failed to restore used and missing lights for over 02 months in addition, vessel failed to follow shipboard manuals and guidance for the deficiencies listed as 03, 04 and 05. An additional internal audit is required.
74SOLAS(14)IX/3.1, ISM Code 10.3, ISM Code 6.4.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received internal audits attesting to the SMS procedures
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 December 2020Resolved
Electrical installations shall be such that electrical services essential for safety will be ensued under various emergency conditions.
PSCO observed over 15 general and emergency lighting fixtures (lamps) extinguished throughout the engine room with no additional spares on board for repair.
74SOLAS(14)II-1/40.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received Class report attesting to the replacement of over 15 lighting fixtures in the engine room
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 December 2020Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with for the purpose. The Following functional requirements shall be met, shall be maintained ready for use.
PSCO observed that the quick closing valve for the HFO service tank was disconnected from the pneumatic control air, preventing closing in the event of emergency.
74SOLAS(14)II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 December 2020
Resolution: Ships crew reconnected pneumatic control air quick closing valve for the HFO service tank, after PSCO discovered deficiency.
Each vessel vapor connection flange face must have a permanent stud protruding outward that has a 12.7mm (0.5 inch) diameter and is at least 25.4mm (1 inch) long.
PSCO observed both vapor control flange connections on the port side and 01 on the STBD side missing the required stud on the flange face.
46CFR39.2001(j)
Action required: 10 - Deficiency Rectified
Resolved 13 December 2020
Resolution: Ships crew had on board and attached the proper vapor control flanges affixed with the required stud on the flange face.
Whenever there is a hazardous condition either on board a vessel or caused by a vessel or its operation, the owner, agent, master, operator, or person in charge must immediately notify the nearest CG sector...
Vessel failed to report the incinerator inoperable per NOA reporting procedures and the vessels garbage management procedures if such equipment becomes inoperable.
33CFR160.216(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 13 December 2020
Resolution: Master was provide guidance on NOA reporting requirements, Incinerator had been repaired while vessel was at anchorage while in Sector Houston's COTP zone.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 21 July 2017Resolved
0610 - Portside lifeboat air supply only contained approximately two and one half minutes of air. 74SOLAS(14)III/34 LSA Code 4.8 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement. The vessel refilled and serviced the portside lifeboat air supply.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 21 July 2017Resolved
1840 - Audible high level alarm on deck is inoperable. 46CFR153.409(a) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 July 2017
Resolution: Crew replaced high level alarm horn prior to the completion of the examination. PSCO verified system by retesting on deck high level alarms.