SILVER MUNA is a tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in November 2025, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 24 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it60245 - Displacement, Metric Ton 13768 - Convention (Subpart B), Net Ton 29375 - Convention (Subpart B), Gross Ton 49897 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
24 November 2025COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8271549
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2025Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed a missing locking bolt and loose proximity sensor on the No. 1 power pack's suction valve, indicating non-compliance with manufacturer's instructions for proper maintenance.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 27 November 2025
Resolution: Received class surveyor report on rectified deficiency. All sat.
An IOPP shall be issued to every oil tanker of 150 gross tonnage and above and every other ship of 400 gross tonnage and above. PSCO observed three 3.1 tanks listed on the IOPP, of which the M/E Scavenger Air Box Drain Tank was not listed. PSCO observed multiple entries within the ORB Part I utilizing the aforementioned tank for the collection of oil residues. RO to provide clarification as to the inclusion of M/E Scav Air Box Drain Tank as an approved 3.1 tank.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 5 November 2018
Resolution: RO clarified M/E scav drain does not meet 3.2 or 4.0 requirements of MARPOL Reg 12. VSL will continue to record in ORB as 11.4. Not a def. Entered for ADMIN oversight.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 17 June 2017Resolved
74 SOLAS II-1/44.2 - 1499 - EACH EMERGENCY GENERATING SET TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH A STARTING DEVICE APPROVED BY THE ADMINISTRATION. A SECOND INDEPEDENENT MEANS SHALL BE PROVIDED. UPON ARRIVAL, THE VESSEL NOTIFIED USCG THAT THE EMERGENCY GENERATOR'S SECONDARY MEANS OF STARTING WAS INOPERABLE DUE TO SPRING BEING STUCK. CAPTAIN ADVISED PART SHOULD ARRIVE 18JUN17.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2017
Resolution: USCG ON BOARD TO CLEAR DEF. OP-TESTED E-GEN SECONDARY START WITH POSITIVE RESULTS. DEF CLEARED BY CWO A. RIDOLF (SECMOB).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National