IB1602 is a 2016 tank barge. The Coast Guard has recorded 8 inspections since 2016, most recently in November 2023, along with 1 deficiency.

Records from 2016 to 2023. Most recent: inspection, 28 November 2023.

Built
2016
Last inspected
28 November 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1396951
Flag
UNITED STATES
—
Maury page id
psix-1396951

Inspections, by type

Years with a record 7 calendar years (2016–2023)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · Jeffersonville, IN, UNITED STATES · built 2016
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 October 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

28 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7830663
1 November 2021 Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7343567
9 December 2020 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7109232
27 December 2019 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6879555
12 December 2019 MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6872441
23 October 2018 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6566583
18 December 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324375
22 August 2016 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5980083

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 December 2019 Resolved
Repair or replace the frayed prime mover emergency shut down pull cable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 January 2020
Resolved 27 December 2019
Resolution: Cropped and renewed frayed section of shutdown cable.