Records from 2019 to 2024. Most recent: inspection, 21 July 2024.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 13 December 2023
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working streses to which it may be subjected. PCSO observed steam leak on supply line to fresh water generator.
74SOLAS (20) II-1/33.1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 December 2023
Resolved 21 July 2024
Resolution: Received Class Report attesting to the rectiifcation of the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 December 2023
Resolved
After any survey of the ship under regulation ...10 has been completed, no change shall b made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. PSCO observed a temporary repair to the main engine cooler sea water line. 74 SOLAS(20) II 11b 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 December 2023
Resolved 21 July 2024
Resolution: Received Class Report attesting to the rectiifcation of the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 December 2023
Resolved
Each set of safety belts for a seat shall be of a colour which contrasts with the belts for seats immediately adjacent. PSCO observed safety belts of same colour adjacent to each other. 74SOLAS(20) III/31.1.1.2.1 LSA CODE 4.6.3.1 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 December 2023
Resolved 21 July 2024
Resolution: Received Class Report attesting to the rectiifcation of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 December 2023
Resolved
No flammable or combustible liquids may be stowed in any accomodation control or service space (other than a paint locker). PSCO observed used paint cans in bosun stores. 46 CFR 147.45b 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2023
Resolved
Nozzles shall be of an approved dual purpose type (i.e. Spray/jet) incorporating shut off. PSCO observed 01 fire station with nozzle only capable of jet setting. 74SOLAS (09) II-2/10.2.3.3.4 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 October 2019
Resolved
02199
Structural Conditions
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed degradation to the refractory of the vessel's incinerator.
74 SOLAS(a) 2014 cons. I/11(a)
16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 6 October 2019
Resolution: Received, reveiewed, and accepted class report from [name withheld] stating the deficiency was rectified. Crewed completed repairs to the major cracks in the refractory.