Inspection history · 14
9 October 2024
Annual Inspection · Administrative Inspection · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8016910
10 October 2023
Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7806241
18 January 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7623942
19 December 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7611026
5 October 2021
DAPI Audit · Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7326223
22 October 2020
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7084356
27 December 2019
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6879527
8 October 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6841906
10 January 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6608987
30 October 2018
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6571454
9 January 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6290303
19 January 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6070619
18 November 2016
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6043669
16 June 2016
Simplified Stability Test · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5961238
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2023
Resolved
Electrical equipment on a vessel must be installed to minimize accidental personnel contact with energized parts. Provide protective cover for active / live connections on battery switch located at operating console.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2023
Resolution: Vessels owner satisfactorily covered exposed electrical components.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2023
Resolved
Each floating waterlight must e approved in accordance with 161.010. Vessels waterlight did not work. Vessel restricted to daylight operations until deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 October 2023
Resolution: Inspected new waterlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
Fuel oil shut off valves are to be installed as close as practical to tank connection. Vessel had shut off valve located down stream at supply to F/O filter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2023
Resolution: Inspected f/o shut-off valves correctly installed at tank suction.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 December 2022
Resolved
This vessel is absent of VHF-DSC radio capabilities. All domestic passenger vessels that carry more than six passengers, with at least one for hire, must be equipped with a functional VHF-DSC radio. Provide evidence of properly functioning DSC radio or servicing report.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2023
Resolved 15 May 2023
Resolution: Received photographs of new FCC documentation and VHF-DSC installation; satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 December 2022
Resolved
Each inspected vessel is required to have a sufficient amount of alcohol testing devices ready accessible on board. This vessel contains expired alcohol testing kits. Provide approved equipment able to sufficiently conduct alcohol testing for the crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2023
Resolved 19 January 2023
Resolution: Received photograph of sufficient and unexpired alcohol testing devices; satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 December 2022
Resolved
All inspected passenger vessels are required to carry the following publications up-to-date: Nautical Chart, U.S. Coast Pilot [name withheld] List, Tide Tables, and Current tables. This vessel currently maintains outdated publications. Provide evidence of updated publications for the vessel's intended voyage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2023
Resolved 19 January 2023
Resolution: Received photograph of sufficient and updated Nautical Publications; satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 December 2022
Resolved
This vessel is absent of 03 hand orange smoke distress signals. Provide evidence of valid quantity of distress signals and/or flares for intended route.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2023
Resolved 19 January 2023
Resolution: Received photograph of sufficient/unexpired distress signals; satisfactory.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 October 2019
Resolved
Owner was missing FCC Station license and Safety Radiotelephony certificate. Provide proof of license and certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 27 December 2019
Resolution: Owner provide proof of missing FCC certificates.