Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it59349 - Dead Weight, Metric Ton 80854 - Displacement, Metric Ton 74906 - Convention (Subpart B), Gross Ton 44353 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 33
11 May 2026PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8367137
7 November 2025PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8265641
8 April 2025PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8108108
30 September 2024PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8011694
22 January 2024PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7848366
20 June 2023PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7718952
15 March 2023Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7650908
5 December 2022PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7604269
22 August 2022Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7540912
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 May 2026Resolved
THE ARRANGEMENTS OF SEA CONNECTIONS, FIRE PUMPS AND THEIR SOURCES OF POWER SHALL BE AS TO ENSURE THAT...IN CARGO SHIPS, IF A FIRE IN ANY ONE COMPARTMENT COULD PUT ALL THE PUMPS OUT OF ACTION, THERE SHALL BE AN ALTERNATIVE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP COMPLYING WITH THE PROVISIONS OF THE FIRE SAFETY SYSTEMS CODE WITH ITS SOURCE OF POWER AND SEA CONNECTION LOCATED OUTSIDE THE SPACE WHERE THE MAIN FIRE PUMPS OR THEIR SOURCES OF POWER ARE LOCATED. THE CAPACITY OF THE PUMP SHALL NOT BE LESS THAN 40% OF THE TOTAL CAPACITY OF THE FIRE PUMPS REQUIRED BY REGULATION II-2/10.2.2.4.1 OF THE CONVENTION AND IN ANY CASE NOT LESS THAN THE FOLLOWING. 25M3/H FOR CARGO SHIPS OF 2,000 GROSS TONNAGE AND UPWARDS. [name withheld] THAT THE EMERGENCY FIRE PUMP WAS NOT PROVIDING SUFFICIENT PRESSURE WHILE TESTING. 74SOLAS(09)II-2 REG.10.2.2.3.1.2, FSS CODE CHAP. 12 2.2.1.1.1, 17(A)(C)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2026
Resolution: Sector Columbia River received a Class Survey from Class [name withheld] stating the deficiency was properly fixed and rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2020Resolved
13101- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While in the Port of Tampa Bay, vessel experienced a loss of propolsion. The loss of propolsion took place on 12 June 2020.
74 SOLAS (14 cons) CH I/Reg. 11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2020
Resolution: Received class report attesting to the proper function of the M/E.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 June 2020Resolved
09110- Electrical installations shall be such that the safety of crew and ship will be ensured. PSCO observed two missing switches on the MDO transfer pump control box and No. 2 HFO transfer pump control box located in the purifier room.
74 SOLAS (14cons) CH II-1/ Reg. 40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2020
Resolution: Class attended the vessel and verified proper installation of the two missing switches. USCG also attended the vessel to verify.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2020Resolved
07199- Means shall be provided to control the leaks of flammable liquids. PSCO observed 07 firefighting steam lines on the main engine having full soaked lagging.
74 SOLAS (09cons) CH II-2/Reg. 4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2020
Resolution: Leak was repaired and new lagging was installed and verified by both class and USCG.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2020Resolved
07199- Means shall be provided to control the leaks of flammable liquids. PSCO observed fuel soaked lagging surrounding the #1 M/E fuel feed pump,#1 M/E fuel booster pump, and generator MDO flusing pump.
74 SOLAS (09cons) CH II-2/Reg. 4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2020
Resolution: Leak was repaired and new lagging was installed and verified by both class and USCG.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2020Resolved
Electrical installations shall be such that the safety of passengers, crew, ship from electrical hazards will be ensured. Multiple junction boxes and covers are wasted and disconnected in the following locations:
1)Portside lifeboat mushroom galley exhaust – Frame 55, Deck B
2)Starboard main deck passage machine supply – Frame 132
3)Port main deck passage machine supply – Frame 132
4)Aft Midship steering gear mushroom vent – Frame 12
74 SOLAS 2004 Ch2-1 Reg 40.1.3 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2020
Resolution: Received KR Class report, with photos attached, attesting to the repair of items listed in the deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2020Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The Port and Starboard fuel hose handling davit were found with the following:
1)Starboard side crane limit switch activator is wasted
2)Port side limit switch is inoperable
3)Port side electrical connection to davit motor was observed with exposed wires/wasted insulation
74 SOLAS (14) I/11(a) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2020
Resolution: Received KR Class report, with photos attached, attesting to the repair and satisfactory operation of the above deficicencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2018Resolved
74 SOLAS (14) 1/11(a) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regualtions to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
The casing cover on the lube oil injection unit assocoaited with the main engine had carcks on it.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2018
Resolution: Received Class report attesting to repairs.
CODE: 0599 CITE: 74 SOLAS (2007 CONS.) II-1/26.1 ACTION: 40ac
THE MACHINERY SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. RECENT LEAKAGE AROUND CYLINDER 7, OTHER VARIOUS MACHINERY, AND OTHER ENGINE ROOM SPACES DO NOT COMPLY WITH GENERAL HOUSE KEEPING PRACTICES.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2017
Resolved 16 July 2017
Resolution: SEE CLASS REPORT.
Engineering › Fuel Oil Service System › Piping
Issued 8 July 2016Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard and shall at least comply with the following provisions. Main engine booster pump was leaking with excess fuel oil. Repairs to be completed to the satisfaction of the class society. 74SOLAS(14) II-2/14.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2016
Resolution: Class report attest to satisfactory maintenance to the Purifer piping system. Deficiency cleared...PO Munk.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 July 2016Resolved
The condition of the ship and its equipment shal be maintained to conform with the provisions of the present requirments to ensure that the ship in all respects remain fit to proceed to sea without danger to the ship and persons on board. emergency generator was noted with a leaking coolant servace valve. Repair to the satisfaction of class. 74SOLAS04/I-II
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 October 2016
Resolution: Class report attest to satisfactory maintenance on generator. Deficiency cleared...[name withheld].
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.