09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 November 2024
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Marine inspectors observed exposed exhaust components on port and starboard engine turbo assemblies subject to temperatures greater than 150 degrees to be missing insulation.
46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 12 November 2024
Resolution: Vessel tightened and repositioned exhaust lagging as well as installed a new turbo insulating cover on the port engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine inspectors observed excessively chaffed areas of both port and starboard engine cooling hoses that resulted in exposed secondary wire layer.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 12 November 2024
Resolution: Vessel replaced hoses and installed anti-chafe sleeves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine inspectors observed dry rotted sections of exhaust cooling water hoses on both port and starboard engines.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 12 November 2024
Resolution: Vessel Replaced dry rotted hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2024
Resolved
All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Marine inspectors observed the onboard generator data plate stamped temperature rating of 40 degrees celsius. Vessel engineering space is not equipped with power ventilation and may be susceptible to temperatures exceeding the listed generator maximum output temperature rating, MIs also observed a main breaker rating of 90 amps. Vessel must provide objective evidence to show that the installed generator and main breaker rating is capable of performing the allowable output at the temperatures experienced within the engineering space without causing undue stress to the installed electrical components.
46 CFR 183.220(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 12 November 2024
Resolution: Vessel replaced the 90 amp breaker with a 40 amp breaker, effectively derating the generator to 80 percent of the peak standby rating of 57.1 amps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable. MI observed single hose clamps on cooling water hoses for both main propulsion engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 12 November 2024
Resolution: Vessel installed double hose clamps in propper locaitons
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 December 2023
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including inspection of all accessible parts of the exterior and interior of the hull. Found previous repairs and cracks in transom which have failed allowing for minor water ingress. Conduct necessary repairs of the transom and provide mitigation for future occurrence.
46 CFR 176.802(a)(1)
50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 3 June 2024
Resolution: MI reviewed necessary repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 December 2023
Resolved
A vessel must comply with the structural design requirements of the standards for aluminum hull vessels. Cracks were observed on multiple frame welds in the aft lazarette space. Submit repair plan for review by lead marine inspector.
46 CFR 177.300(d)
50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 3 June 2024
Resolution: MI reviewed and accepted repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
All machinery and equipment must be installed and maintained in such manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Observed crack and leak on port main engine wet exhaust. Repair to the satisfaction of the lead marine inspector.
46 CFR 182.100
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 11 December 2023
Resolution: Exhaust cracks were welded and photographic documentation provided by vessel rep to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. Observed steering hydraulic hose showing chafing/wear. Conduct necessary repairs and prevent future chafing.
46 CFR 182.720(e)(3)(ii)
16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 11 December 2023
Resolution: Chafing gear installed on affected hydraulic hoses and photographic documentation provided by vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 December 2023
Resolved
All cable and wire must be protected by metal coverings or other suitable means if in areas subject to mechanical abuse. Electrical wire in Engine room is showing sign of chafing. Conduct necessary repairs and prevent future chafing.
46 CFR 183.340(b)(6)
16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 7 May 2024
Resolution: Observed installation of chafing gear on engine room power cables.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 7 December 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Numerous deck railings on the vessel were found significantly cracked at the base. Conduct necessary repairs.
46 CFR 177.900(b)
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 3 June 2024
Resolution: Railings repaired to MI satisifaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirement. Observed both forward engine mounts on both main engines to be cracked. Cracks on the engine mounts were noted in prior inspections. Given the repeated nature of this matter, submit repair plan to include means of preventing future damage.
46 CFR 182.200(a)
50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 3 June 2024
Resolution: Repairs conducted to the satisfaction of attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 7 December 2023
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including inspection of all accessible parts of the exterior and interior of the hull. In the amidships void space beneath the pilothouse, found vertical stanchion with top welds cracked. Repair as initially designed to satisfaction of USCG.
46 CFR 176.802(a)
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 11 December 2023
Resolution: Stanchion was welded and pictures provided by vessel rep.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 December 2023
Resolved
Piping including valves, pipe fittings, and flanges conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 C, must be suitably insulated where necessary to prevent injuries. Observed lagging insulation poorly installed on both main engines and generator. Repair to satisfaction of USCG.
46 CFR 177.970
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 11 December 2023
Resolution: Lagging was adjusted to properly insulate hot exhaust piping. Pictures provided byb vessel rep.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 August 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. Fire boy engine shutdowns were not operating as intended; repair to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2022
Resolution: Marine inspector witnessed satisfactory engine shutdowns in conjunction with the vessel's Fire boy fixed gas extinguishing system.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2020
Resolved
Expired smoke flare.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2020
Resolved
Each ring buoy must be marked with the vessel's name.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 October 2020
Resolved
Repair cracks on the engine block mounts.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Welded and corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 October 2020
Resolved
Repair through hull fittings where the electrical cables pass from the engine room through the void under the pilot house. There must be a vapor tight seal.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Repaired holes with Fire Stop. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2020
Resolved
Repair oil leak on the Port main engine.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2020
Resolved
Repair air hose connection on the Port main engine.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018
Resolved
Found multiple exposed wires under operating station console. Electrical equipment on a vessel must be installed to protect crew, other persons, and the vessel from electrical hazards.
Corrected on the spot to the satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 October 2018
Resolved 5 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018
Resolved
Found multiple connectors under operating station console that utilized normal spade connectors. Wire connectors utilized in conjunction with screw type terminal block must be of the captive type.
Corrected on the spot to the satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 October 2018
Resolved 5 October 2018