← All vessels
SLAVYANKA
SLAVYANKA is a freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in November 2019, along with 4 deficiencies and 2 operational controls.
Records from 2017 to 2019. Most recent: inspection, 22 November 2019.
- Built
- Not recorded
- Last inspected
- 22 November 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9496276 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4321
1401600
Flag
MALTA
—
Maury page id
psix-1401600
Inspections, by type
…with no type recorded2
Years with a record
3 calendar years (2017–2019)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it20924 - Convention (Subpart B), Gross Ton
11786 - Convention (Subpart B), Net Ton
32252 - Dead Weight, Metric Ton
41748 - Displacement, Metric Ton
11786 - Convention (Subpart B), Net Ton
32252 - Dead Weight, Metric Ton
41748 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
22 November 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6837536
3 October 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6827153
31 May 2019
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699503
29 May 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6698743
17 September 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6530829
7 August 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6223625
3 August 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6229140
3 August 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6229192
Deficiency record · 4
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 17 September 2018
Resolved
OIL FILTERING EQUIPMENT SHALL BE FITTED WITH AN ALARM AND SHALL BE PROVIDED WITH ARRANGEMENTS TO AUTOMATICALLY STOP DISCHARGE WHEN OIL CONTENT IS IN EXCESS OF 15 PARTS PER MILLION.
DISCHARGE PUMP FOR OILY WATER SEPARATORIS INOPERABLE.
MARPOL ANNEX I, CHAP. 3, REG.14.7
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 September 2018
Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD BACKS.
VESSEL HAD ARRANGED SEVERAL DOORS IN MAIN ENGINE ROOM WITH HOLD BACKS.
SOLAS 74 (2014) CHAP. II-2, REG. 9.4.2.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 September 2018
Resolved
A SECOND SOURCE SHALL BE PROVIDED TO START EMERGENCY GENERATOR.
CREW WAS UNABLE TO START EMERGENCY GENERATOR WITH SECOND SOURCE.
SOLAS 74 (2004 CONS), CHAP. 11.1, REG. 44.2
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 August 2017
Resolved
0715-Detection- Fire protection system and fire fighting systems and appliances shall be maintained ready for use. PSCO noticed one smoke detector not working over the No#1 fuel oil purifier. Also another smoke detector covered in electrical shop causing an unsafe condition. SOLAS 09 (am) II-2/14.1 17a
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.