Records from 2016 to 2025. Most recent: inspection, 8 May 2025.
Inspection history · 20
8 May 2025
COC-GAS Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130321
7 February 2024
PSC B · COC-GAS Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7859196
24 April 2023
COC-GAS Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662776
28 January 2022
COC-GAS Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7386935
18 January 2021
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7124338
12 January 2020
COC-GAS Renew · ISPS Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884937
26 May 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6720491
14 March 2019
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6642391
29 November 2018
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6584757
17 August 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6514657
13 February 2018
COE-Dockside · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6351238
26 November 2017
Ballast Water Examination · COC-GAS Annual · Administrative Inspection · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6311567
28 October 2017
COE-Offshore
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6297276
24 August 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6251249
12 June 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6173320
12 June 2017
COE-Offshore
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6174916
22 May 2017
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6152671
29 April 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6135393
22 January 2017
COE-Dockside · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6074806
22 November 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6046310
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 18 January 2021
Resolved
Alarms for gas sampling systems should be activated when the vapor concentration reaches the threshold limiting value. During testing of the ammonia sensor while the ship was discharging ammonia cargo, the sensor was unable to be calibrated by the crew. Crew replaced sensor and conducted calibration in accordance with manufacturer's instructions. PSCO witnessed successful calibration. Recommend third party calibration in accordance with company policy as soon as practicable.
74SOLAS(14) Ch. VII/Reg 13
IGC 1993 Ch. 17.9
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2021
Resolved 18 January 2021
Resolution: Corrected on the spot. Crew installed new sensor and and conducted satisfactory calibration in accordance with manufacturer's instructions.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 30 April 2017
Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. Cylinders #2 and 3 failed due to low voltage in software module on main machinery installation. Provide class report attesting to proper operation prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2017
Resolution: Received class report attesting to proper operation. Attached ABS survey to activity.