Records from 2016 to 2025. Most recent: inspection, 2 October 2025.
Inspection history · 15
2 October 2025
COC-CHEM & TVE Annual · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8243895
26 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8218564
19 June 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8162517
21 September 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8004232
10 December 2022
Administrative Inspection · COC-CHEM & TVE Annual · PSC C
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7607113
7 February 2022
COC-CHEM & TVE Renew · Deficiency Check · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7389725
11 December 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6872048
3 December 2019
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864778
30 November 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864803
27 November 2018
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6584945
26 February 2018
COE-Dockside
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6361104
29 October 2017
ISPS II Exam · COE-Dockside · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6296991
6 April 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6118838
19 March 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6107379
23 September 2016
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6006150
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2019
Resolved
01- 08199-THE GAS DETECTION EQUIPMENT SHALL BE SO DESIGNED THAT IT MAY READILY BE TESTED AND CALIBRATED. PSCO NOTED CREW UNABLE TO TEST ALARMS ON FIXED GAS DETECTION SYSTEM WITH SPAN GAS. 47SOLAS(14)II/4.5.7.3.1
FSS CODE 16.2.2.3.4
10C
Action required: 10 - Deficiency Rectified
Due 3 December 2019
Resolved 3 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 3 December 2019
Resolved
02- 11124-MUSTER AND EMBARKATIONS SHALL BE ADAQUATELY ILLUMINATED BY LIGHTING SUPPLIED FROM THE EMERGENCY SOURCE OF ELETRICAL POWER REQUIRED BY REGULATION II-1/43.PSCO NOTED THERE IS NOT AN EMBARKATION LIGHT FOR THE FOREWARD LIFE RAFT.
74SOLAS(14)111/11.4 20AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2019
Resolved 11 February 2022
Resolution: Vessel provided lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 December 2019
Resolved
03- 11132-INSTRUCTIONS FOR ONBOARD MAINTAINANCE OF LIFE SAVING APPLIANCES COMPLYING WITH REG 36 SHALL BE PROVIDED AND MAINTENANCE SHALL BE CARRIED OUT ACCORDINGLY. PSCO NOTED INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFE RAFTS WAS NOT PROVIDED. INSTRUSTIONS FOR ON BOARD MAINTENANCE OF LIFE SAVING APPLIANCES MISSING 74SOLAS(14)111/20.3.2 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2019
Resolved 11 February 2022
Resolution: Instructions were provided on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2019
Resolved
04- 11117- BEFORE THE SHIP LEAVES AND AT ALL TIME DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO NOTED THAT THE RING BUOYS AT THE FOLLOWING LOCATIONS ARE NOT IN COMPLIANCE WITH THE APPLICABLE LSA REQUIREMENTS.
1. RING BUOY AT FR 54P IS DAMAGED
2. RING BUOY AT FR 48S NEEDS RETRO REFLECTIVE MATERIAL AND WATER LIGHT IS NOT ATTACHED.
3. RING BUOY AT FR 48P AND FR 56P NEEDS RETROFLECTIVE MATERIAL.
SOLAS74(14)20.2
LSA CODE 2.1
16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 11 December 2019
Resolution: RETROREFLECTIVE TAPE HAS BEEN REPLACED AND IN GOOD ORDER.