MAURY USCG vessel records
← All vessels

MAERSK ELBA

MAERSK ELBA is a freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in September 2022, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2022. Most recent: inspection, 21 September 2022.

Built
Not recorded
Last inspected
21 September 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9458078
1405607
Flag
DENMARK
Maury page id
psix-1405607

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it63729 - Convention (Subpart B), Net Ton
148604 - Dead Weight, Metric Ton
191870 - Displacement, Metric Ton
141716 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 9

21 September 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7563519
8 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364970
21 July 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7263185
16 September 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6812920
23 May 2019 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6691685
19 May 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6687591
8 March 2018 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6368214
22 November 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6046028
3 August 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5963473

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 September 2022 Resolved
Oil fuel pipes, which if damaged would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO discovered quick closing valves of HFO Service tank to main engine, generators 1,3, and 4 did not close fully.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2022
Resolution: Vessel provided class documentation rectifing deficiency. Class documents uploaded to MISLE.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 September 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. PSCO found that the emergency generator weekly checklist did not include procedures for manual testing of the emergency shutoff valve. Ship is required to conduct an internal audit and take an internal audit within three (3) months due to the procedures for checking emergency generator not sufficient to prevent operational readiness.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 25 September 2022
Resolution: Vessel completed internal audit on 24SEP22. Interal audit document uploaded to MISLE.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 September 2022 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met. Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. PSCO discovered the emergency shutoff valve of the storage tank for the emergency generator was in a closed position.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 September 2022
Resolution: PSCO observed successful operation of the quick closing valve

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.