AREQUIPA QUEEN is a 2016 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in December 2024, along with 5 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: inspection, 20 December 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it30598 - Convention (Subpart B), Gross Ton 51024 - Dead Weight, Metric Ton 61043 - Displacement, Metric Ton 15707 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
20 December 2024PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8045085
21 September 2022PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7554054
4 January 2021Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7119041
4 January 2021Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7119275
3 January 2021Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7120377
17 December 2020Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7105595
3 June 2020PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6961132
30 November 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6859193
8 November 2018PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6573520
27 January 2018Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6344642
8 August 2017ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6225147
31 July 2016Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5951328
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 January 2021Resolved
It was reported that the vessel had a Fuel Injection Valve Assembly failure
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 January 2021
Resolved 4 January 2021
Resolution: Reviewed and accepted class report from NKK. The report stated that the (FIVA) failed and had been replace in kind as new and testd accordingly.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 November 2018Resolved
07103 -IN ADDITION TO COMPLY WITH THE SPECIFIC PROVISIONS FOR FIRE INTEGRITY OF BULKHEADS AND DECKS OF CARGO SHIPS, THE MINIMUM FIRE INTEGRITY OF BULKHEADS AND DECKS SHALL BE PRESCRIBED IN TABLES 9.5 AND 9.6. PSCO OBSERVED AN OPENING IN THE DECK OF THE ENGINE ROOM, BEHIND THE SWITCHBOARD, THAT LED DIRECTLY INTO THE MAIN MACHINERY SPACE, WHERE AN A 60 BOUNDARY IS REQUIRED.
74 SOLAS (2014 CONS.) II-2/9.2.3.3.1
16A
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 12 November 2018
Resolution: Recieved class report statisfying requirement.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2018Resolved
07124 - MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION.
PSCO OBSERVED YEARLY FIRE PROTECTION MAINTENANCE WAS OVERDUE AND THE LAST PREFORMED ON OCTOBER 24TH, 2017
74 SOLAS (2014 CONS.) II-2.14.2.2
16A
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 12 November 2018
Resolution: Recieved class report statisfying requirement.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 8 November 2018Resolved
14503 - EVERY SHIP OF 100 GT AND ABOVE SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW SHALL FOLLOW. SUCH PLAN SHALL BE BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION.
PSCO OBSERVED THE VESSEL WAS OPERATING WITH AN OUT OF DATE GARBAGE MANAGEMENT PLAN. CREW WAS ABLE TO OBTAIN NEW VERSION OF GARBAGE MANAGEMENT PLAN DURING PSC EXAM AND DISPOSED OF ALL COPIES OF OUTDATED MANUAL.
MARPOL 73/76 ANNEXV/10.2
10C
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 8 November 2018
Resolution: MASTER PROVIDED UPDATED GARBAGE MANAGEMENT PLAN TO RECTIFY THE DEFICIENCY.
1730-Oily-water separating equipment-OIL FILTERING EQUIPMENT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN LEVEL CANNOT BE MAINTAINED. PSCO WITNESSED AN OPERATIONAL TEST OF THE ON BOARD OWS/OCM, DURING THE TEST THE CREW WAS UNABLE TO SIMULATE OVER 15PPM ON THE OIL CONTENT METER IAW TESTING PROCEDURES. ALL OTHER ASPECTS OF THE SYSTEM WERE WORKING AS INTENDED. MARPOL 1/14.7 40a
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 August 2017
Resolved 27 January 2018
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.